<em>Temperature is the most important parameter in monitoring Infant Warmer medical equipment. In this study, temperature monitoring was carried out on the Lullaby GE Infant Warmer using INCU based on Arduino Uno. The temperature setting used was 34 ° C, 35 ° C, 36 ° C and 37 ° C with each setting repeated 3 times. The temperature sensor used in the INCU analyzer for T1 to T4 is DS18B20, while the T5 uses a DHT22 temperature sensor. At the Infant Warmer temperature, a low error value was obtained for all temperature settings, namely a temperature of 34 ° C with an error of 0.02, a temperature of 35 ° C with an error of 0.03, a temperature of 36 ° C with an error of 0.004 and a temperature of 37 ° C with an error of 0. The INCU analyzer output low temperature is at T5, with temperature settings of 34 ° C, 35 ° C, 35 ° C and 37 ° C respectively 0.009, 0.07, 0.11 and 0.28. While the error value on T1 to T4 ranges from 0.37, namely at T3 for a temperature setting of 35 ° C to 0.84, namely at T3 for a setting of 37 ° C. It can be concluded that the INCU analyzer that has a high degree of accuracy is the T5 using the DHT22 temperature sensor.</em>
The climatic chamber is a calibration medium for the thermohygrometer. This simple climatic chamber was built using the Arduino uno, DHT22 sensor, heater, and peltier. The climatic chamber was designed and manufactured well and cheaply. Climatic chamber testing of the design results is carried out to determine the success rate of the tool. Tests are carried out using the Madgetech data logger tool through monitoring or monitoring of temperature within a certain period of time. The results of temperature monitoring at two observed values, namely temperatures of 250C to 300C and temperatures of 300C to 350C, showed good results with the corresponding rhythm of temperature increase and temperature decrease. It's just that the decrease in temperature still takes longer than the increase in temperature. This shows that the heater can be said to be working optimally and the peltier is not fully working. So it is necessary to do further studies related to the peltier for the climatic chamber both in terms of number and characteristics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.