To discuss the advantages and limitation of the different pelvic floor muscle (PFM) dynamometers available, both in research and industry, and to present the extent of variation between them in terms of structure, functioning, psychometric properties, and assessment procedures. Methods:We identified relevant studies from four databases (MEDLINE, Compendex, Web of Science, and Derwent Innovations Index) up to December 2020 using terms related to dynamometry and PFM. In addition, we conducted a hand search of the bibliographies of all relevant reports. Peer-reviewed papers, conference proceedings, patents and user's manuals for commercial dynamometers were included and assessed by two independent reviewers. Results: One hundred and one records were included and 23 PFM dynamometers from 15 research groups were identified. From these, 20 were considered as clinical dynamometers (meant for research settings) and three as personal dynamometers (developed by the industry). Overall, significant heterogeneity was found in their structure and functioning, which limits development of normative data for PFM force in women. Further research is needed to assess the psychometric properties of PFM dynamometers and to standardize assessment procedures. Conclusion:This review points up to the heterogeneity of existing dynamometers and methods of assessing PFM function. It highlights the need to better document their design and assessment protocol methods.
In attempts to improve the quality of life of women, continuous projects are sought between rehabilitation intervention and engineering. Using the knowledge of the pelvic floor muscle (PFM) physiology, assessment and training methods are developed to reduce lower urinary tract symptoms such as urinary incontinence. Therefore, this paper covers the design and implementation of a portable vaginal dynamometer. Methods: A PFM probe is designed, 3D printed, assembled, and tested in ten women to assess its acceptability and usability. The feedback from the usability study is used to optimize the PFM probe design. A vaginal dynamometer is developed based on the designed PFM probe, then tested for linearity, repeatability, hysteresis, noise and heat effect, and power consumption. The variability between the different produced PFM probe prototypes is evaluated. Results: Force measurements are made using a load cell. Wireless communication is performed through a Bluetooth low energy transceiver v5.0, with a corresponding interface on both computer and smartphone. The device operates at a 3.3V supply and achieves a power consumption of 49.5 mW in operating mode. Two PFM probe sizes are designed to accommodate different vaginal hiatus sizes, based on usability study feedback. The proposed system allows the physiotherapist to wirelessly monitor variation in pelvic floor muscle force during assessment and/or training. Discussion/Conclusion: The testing results showed that the newly designed system has the potential to measure the PFM function in functional conditions such as the standing position.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.