BackgroundThe measurement of Interferon gamma or Interferon gamma inducible protein (IP)-10 in antigen stimulated blood samples is suggested as an alternative method for latent tuberculosis (TB) diagnosis. Nonetheless, their role in active TB diagnosis, particularly in TB endemic settings is yet to be defined. In this study, the sensitivities and specificities of Interferon gamma release assay (IGRA), IP-10 assay and tuberculin skin test (TST) in detecting active TB cases were assessed in human immunodeficiency virus (HIV) sero-negative TB patients and healthy controls respectively.Methods/Principal FindingsA total of 177 adult TB patients and 100 healthy controls were included for this study. QuantiFERON-TB Gold In-tube (QFT-IT) method was used to analyze the sensitivity and specificity of IGRA. QFT-IT, IP-10 and TST yielded the diagnostic sensitivities of 90.6% (95%CI: 86.3%–94.9%), 92.5% (95%CI: 88.6%–96.4%) and 68.9% (95%CI: 60.6%–77.2%) and specificities of 55% (95% CI: 35.2%–54.8%), 48% (95% CI: 38.2%–57.8%) and 75.5% (95% CI: 66.8%–84.2%), respectively. The extent of pulmonary involvement or presence of diabetes mellitus did not appear to influence the sensitivities of any of these tests. The combination of any of the two tests among QFT-IT, IP-10 and TST showed >98% sensitivity among smear negative cases and particularly the combination of IP-10, TST and smear microscopy showed 100% sensitivity, however, the specificity was decreased to 44.8%.Conclusions/SignificanceQFT-IT and IP-10 were highly sensitive in detecting active TB cases. The combination with TST improved the sensitivity of QFT-IT and IP-10 significantly. Although the higher sensitivity of combination of QFT-IT/IP-10 and TST may be useful in active TB diagnosis, they are limited by their poor specificity due to the high prevalence of latent TB in our settings.
BackgroundThe suboptimal sensitivity of Interferon (IFN)-γ-based in-vitro assays, especially in immunocompromised individuals, emphasizes the need for alternative markers for diagnosing tuberculosis (TB). The objective of this study was to evaluate whether interferon-inducible protein (IP)-10, monocyte chemotactic protein (MCP)-2 and interleukin (IL)-2 can be useful biomarkers for evaluating a specific response to RD1 antigens associated to active TB disease in HIV-infected individuals.Methodology/Principal FindingsThe study was carried out in India, the country with the highest TB burden in the world. Sixty-six HIV-infected individuals were prospectively enrolled, 28 with active-pulmonary-TB and 38 without. The whole blood assay based on RD1-selected peptides (experimental test) and QuantiFERON-TB Gold In tube (QFT-IT) was performed. Plasma was harvested at day-1-post-culture and soluble factors were evaluated by ELISA. The results indicate that by detecting IP-10, the sensitivity of the experimental test and QFT-antigen (75% and 85.7% respectively) for active TB was higher compared to the same assays based on IFN-γ (42.9% and 60.7% respectively) and was not influenced by the ability to respond to the mitogen. By detecting IP-10, the specificity of the experimental test and QFT-antigen (57.9% and 13.2% respectively) for active TB was lower than what was reported for the same assays using IFN-γ-detection (78.9% and 68.4% respectively). On the other side, in vitro IL-2 and MCP-2 responses were not significantly associated with active TB.ConclusionsHIV infection does not impair RD1-specific response detected by IP-10, while it significantly decreases IFN-γ-mediated responses. At the moment it is unclear whether higher detection is related to higher sensitivity or lower specificity of the assay. Further studies in high and low TB endemic countries are needed to elucidate this.
BackgroundThere is an urgent need of prognosis markers for tuberculosis (TB) to improve treatment strategies. The results of several studies show that the Interferon (IFN)-γ-specific response to the TB antigens of the QuantiFERON TB Gold (QFT-IT antigens) decreases after successful TB therapy. The objective of this study was to evaluate whether there are factors other than IFN-γ [such as IFN-γ inducible protein (IP)-10 which has also been associated with TB] in response to QFT-IT antigens that can be used as biomarkers for monitoring TB treatment.MethodsIn this exploratory study we assessed the changes in IP-10 secretion in response to QFT-IT antigens and RD1 peptides selected by computational analysis in 17 patients with active TB at the time of diagnosis and after 6 months of treatment. The IFN-γ response to QFT-IT antigens and RD1 selected peptides was evaluated as a control. A non-parametric Wilcoxon signed-rank test for paired comparisons was used to compare the continuous variables at the time of diagnosis and at therapy completion. A Chi-square test was used to compare proportions.ResultsWe did not observe significant IP-10 changes in whole blood from either NIL or QFT-IT antigen tubes, after 1-day stimulation, between baseline and therapy completion (p = 0.08 and p = 0.7 respectively). Conversely, the level of IP-10 release to RD1 selected peptides was significantly different (p = 0.006). Similar results were obtained when we detected the IFN-γ in response to the QFT-IT antigens (p = 0.06) and RD1 selected peptides (p = 0.0003). The proportion of the IP-10 responders to the QFT-IT antigens did not significantly change between baseline and therapy completion (p = 0.6), whereas it significantly changed in response to RD1 selected peptides (p = 0.002). The proportion of IFN-γ responders between baseline and therapy completion was not significant for QFT-IT antigens (p = 0.2), whereas it was significant for the RD1 selected peptides (p = 0.002), confirming previous observations.ConclusionsOur preliminary study provides an interesting hypothesis: IP-10 response to RD1 selected peptides (similar to IFN-γ) might be a useful biomarker for monitoring therapy efficacy in patients with active TB. However, further studies in larger cohorts are needed to confirm the consistency of these study results.
BackgroundA rapid and specific test is urgently needed for tuberculosis (TB) diagnosis especially among human immunodeficiency virus (HIV) infected individuals. In this study, we assessed the sensitivity of Interferon gamma release assay (IGRA) in active tuberculosis patients who were positive for HIV infection and compared it with that of tuberculin skin test (TST).Methodology/Principal FindingsA total of 105 HIV-TB patients who were naïve for anti tuberculosis and anti retroviral therapy were included for this study out of which 53 (50%) were culture positive. Of 105 tested, QuantiFERON-TB Gold in-tube (QFT-G) was positive in 65% (95% CI: 56% to 74%), negative in 18% (95% CI: 11% to 25%) and indeterminate in 17% (95% CI: 10% to 24%) of patients. The sensitivity of QFT-G remained similar in pulmonary TB and extra-pulmonary TB patients. The QFT-G positivity was not affected by low CD4 count, but it often gave indeterminate results especially in individuals with CD4 count <200 cells/µl. All of the QFT-G indeterminate patients whose sputum culture were positive, showed ≤0.25 IU/ml of IFN-γ response to phytohemagglutinin (PHA). TST was performed in all the 105 patients and yielded the sensitivity of 31% (95% CI: 40% to 22%). All the TST positives were QFT-G positives. The sensitivity of TST was decreased, when CD4 cell counts declined.Conclusions/SignificanceOur study shows neither QFT-G alone or in combination with TST can be used to exclude the suspicion of active TB disease. However, unlike TST, QFT-G yielded fewer false negative results even in individuals with low CD4 count. The low PHA cut-off point for indeterminate results suggested in this study (≤0.25 IU/ml) may improve the proportion of valid QFT-G results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.