The utilization of normothermic machine perfusion (NMP) may be an effective strategy to resuscitate livers from donation after circulatory death (DCD). There is no consensus regarding the efficacy of different perfusates on graft and bile duct viability. The aim of this study was to compare, in an NMP porcine DCD model, the preservation potential of three different perfusates. Twenty porcine livers with 60 min of warm ischemia were separated into four preservation groups: cold storage (CS), NMP with Steen solution (Steen; XVIVO Perfusion Inc., Denver, CO), Steen plus red blood cells (RBCs), or whole blood (WB). All livers were preserved for 10 h and reperfused to simulate transplantation for 24 h. During preservation, the NMP with Steen group presented the highest hepatocellular injury. At reperfusion, the CS group had the lowest bile production and the worst hepatocellular injury compared with all other groups, followed by NMP with Steen; the Steen plus RBC and WB groups presented the best functional and hepatocellular injury outcomes, with WB livers showing lower aspartate aminotransferase release and a trend toward better results for most parameters. Based on our results, a perfusate that contains an oxygen carrier is most effective in a model of NMP porcine DCD livers compared with Steen solution. Specifically, WB-perfused livers showed a trend toward better outcomes compared with Steen plus RBCs.
Normothermic machine perfusion (NMP) is an emerging technology to preserve liver allografts more effectively than cold storage (CS). However, little is known about the effect of NMP on steatosis and the markers indicative of hepatic quality during NMP. To address these points, we perfused 10 discarded human livers with oxygenated NMP for 24 hours after 4-6 hours of CS. All livers had a variable degree of steatosis at baseline. The perfusate consisted of packed red blood cells and fresh frozen plasma. Perfusate analysis showed an increase in triglyceride levels from the 1st hour (median, 127 mg/dL; interquartile range [IQR], 95-149 mg/dL) to 24th hour of perfusion (median, 203 mg/dL; IQR, 171-304 mg/dL; P = 0.004), but tissue steatosis did not decrease. Five livers produced a significant amount of bile (≥5 mL/hour) consistently throughout 24 hours of NMP. Lactate in the perfusate cleared to <3 mmol/L in most livers within 4-8 hours of NMP, which was independent of bile production rate. This is the first study to characterize the lipid profile and functional assessment of discarded human livers at 24 hours of NMP. Liver Transplantation 24 233-245 2018 AASLD.
Ex-situ normothermic limb perfusion preserves swine limb physiology and function for at least 12 hours.
The primary aim of this single-center, phase 1 exploratory study was to investigate the safety, feasibility, and impact on intrahepatic hemodynamics of a fresh frozen plasma (FFP)-based perfusate in ex situ liver normothermic machine perfusion (NMP) preservation. Using an institutionally developed perfusion device, 21 livers (13 donations after brain death and 8 donations after circulatory death) were perfused for 3 hours 21 minutes to 7 hours 52 minutes and successfully transplanted. Outcomes were compared in a 1:4 ratio to historical control patients matched according to donor and recipient characteristics and preservation time. Perfused livers presented a very low resistance state with high flow during ex situ perfusion (arterial and portal flows 340 ± 150 and 890 ± 70 mL/minute/kg liver, respectively). This hemodynamic state was maintained even after reperfusion as demonstrated by higher arterial flow observed in the NMP group compared with control patients (220 ± 120 versus 160 ± 80 mL/minute/kg liver, P = 0.03). The early allograft dysfunction (EAD) rate, peak alanine aminotransferase (ALT), and peak aspartate aminotransferase (AST) levels within 7 days after transplantation were lower in the NMP group compared with the control patients (EAD 19% versus 46%, P = 0.02; peak ALT 363 ± 318 versus 1021 ± 999 U/L, P = 0.001; peak AST 1357 ± 1492 versus 2615 ± 2541 U/L, P = 0.001 of the NMP and control groups, respectively). No patient developed ischemic type biliary stricture. One patient died, and all other patients are alive and well at a follow-up of 12-35 months. No device-related adverse events were recorded. In conclusion, with this study, we showed that ex situ NMP of human livers can be performed safely and effectively using a noncommercial device and an FFP-based preservation solution. Future studies should further investigate the impact of an FFP-based perfusion solution on liver hemodynamics during ex situ normothermic machine preservation. Liver Transplantation 26 215-226 2020 AASLD.Among the strategies employed to improve liver allograft utilization, ex situ normothermic machine perfusion (NMP) preservation has drawn increasing interest in the last decade. The potential advantage of this technology over static cold storage is the ability to enhance preservation along with the capacity to assess and improve graft viability. This is of particular importance when considering organs from extended criteria donors. (1) The type of perfusion solution plays a critical role in the success of NMP. Clinical studies in ex situ preservation have employed packed red blood cells (PRBCs) as oxygen carriers in combination with a colloid extracellular solution (Gelofusine, B Braun, Melsungen, Germany), (2)(3)(4) Steen solution (Gelofusine, B Braun), (5) and 5% albumin (6)(7)(8) ). Fresh frozen plasma (FFP), the most physiological of all extracellular fluids, has never been tested liu et al.
Normothermic machine perfusion (NMP) has been introduced as a promising technology to preserve and possibly repair marginal liver grafts. The aim of this study was to compare the effect of temperature on the preservation of donation after cardiac death (DCD) liver grafts in an ex vivo perfusion model after NMP (38.5°C) and subnormothermic machine perfusion (SNMP, 21°C) with a control group preserved by cold storage (CS, 4°C). Fifteen porcine livers with 60 min of warm ischemia were preserved for 10 h by NMP, SNMP or CS (n = 5/group). After the preservation phase all livers were reperfused for 24 h in an isolated perfusion system with whole blood at 38.5°C to simulate transplantation. At the end of transplant simulation, the NMP group showed significantly lower hepatocellular enzyme level (AST: 277 ± 69 U/L; ALT: 22 ± 2 U/L; P < 0.03) compared to both SNMP (AST: 3243 ± 1048 U/L; ALT: 127 ± 70 U/L) and CS (AST: 3150 ± 1546 U/L; ALT: 185 ± 97 U/L). There was no significant difference between SNMP and CS. Bile production was significantly higher in the NMP group (219 ± 43 mL; P < 0.01) compared to both SNMP (49 ± 84 mL) and CS (12 ± 16 mL) with no significant difference between the latter two groups. Histologically, the NMP livers showed preserved cellular architecture compared to the SNMP and CS groups. NMP was able to recover DCD livers showing superior hepatocellular integrity, biliary function, and microcirculation compared to SNMP and CS. SNMP showed some significant benefit over CS, yet has not shown any advantage over NMP.
Background Normothermic machine perfusion (NMP) is an alternative strategy for preserving kidneys donated after cardiac death (DCD). The relative efficacy of prolonged NMP compared to hypothermic machine perfusion (HMP) in DCD kidneys with moderate ischemic injury is undetermined. This study compares NMP and HMP kidney preservation in a porcine DCD model. Methods Ten porcine kidneys underwent NMP or HMP preservation following 45 minutes of warm ischemia and 5 hours of cold ischemia. After 8 hours of machine preservation, hemodynamic stability, renal function, perfusate biomarkers, and histologic integrity were assessed in a simulated reperfusion model. Results Upon simulated reperfusion, no differences were observed in oxygen consumption, urine production, creatinine clearance, fractional excretion of sodium, proteinuria, and perfusate levels of lactate dehydrogenase and aspartate aminotransferase. Resistance was no different after 30 minutes of simulated reperfusion. NMP kidneys demonstrated increased histologic vacuolization after preservation and greater loss of tubular integrity after simulated reperfusion. Perfusate levels of alkaline phosphatase (AP) and gamma glutamyltransferase (GGT) were higher in NMP kidneys during preservation, but upon simulated reperfusion, AP and GGT levels were higher in HMP-preserved kidneys. Peak AP and GGT during HMP simulated reperfusion were over 14 times higher than peak AP and GGT during NMP preservation. Conclusions NMP provided comparable preservation of renal function as HMP and minimized AP and GGT release upon reperfusion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.