Research on reliability of heart rate variability (HRV) parameters in athletes has received increasing attention. The aims of this study were to examine the inter-day reliability of short-term (5 min) and ultra-short-term (1 min) heart rate (HR), respiratory rate (RespRate) and HRV parameters, agreement between short-term and ultra-short-term parameters, and association between differences in HR, RespRate and HRV parameters in elite modern pentathletes. Electrocardiographic recordings were performed in stable measurement conditions with a week interval between tests. Relative reliability was evaluated by intra-class correlation coefficients, absolute reliability was evaluated by within-subject coefficient of variation, and agreement was evaluated using Bland–Altman (BA) plot with limits of agreement and defined a priori maximum acceptable difference. Short-term HR, RespRate, log transformed (ln) root mean square of successive normal-to-normal interval differences (lnRMSSD), ln high frequency (lnHF) and SD2/SD1 HRV indices and ultra-short-term HR, RespRate and lnRMSSD presented acceptable, satisfactory inter-day reliability. Although there were no significant differences between short-term and ultra-short-term HR, RespRate and lnRMSSD, no parameter showed acceptable differences with BA plots. Differences in time-domain and non-linear HRV parameters were more correlated with differences in HR than with differences in RespRate. Inverse results were observed for frequency-domain parameters. Short-term HR, RespRate, lnRMSSD, lnHF, and SD2/SD1 and ultra-short-term HR, RespRate and lnRMSSD could be used as reliable parameters in endurance athletes. However, practitioners should interpret changes in HRV parameters with regard to concomitant differences in HR and RespRate and caution should be taken before considering 5 min and 1 min parameters as interchangeable.
Monitoring of markers reflecting cardiac autonomic activity before and during stressful situations may be useful for identifying the physiological state of an athlete and may have medical or performance implications. The study aimed to determine group and individual changes in short-term (5 min) and ultra-short-term (1 min) heart rate (HR), respiratory rate (RespRate), and time-domain heart rate variability (HRV) parameters during sympathetic nervous system activity (SNSa) stimulation among professional endurance athletes. Electrocardiographic recordings were performed in stable measurement conditions (Baseline) and during SNSa stimulation via isometric handgrip in 12 elite modern pentathlonists. Significant increases in short-term HR and decreases in time-domain HRV parameters with no changes in RespRate were observed during SNSa stimulation. Significant differences were observed between Baseline (all minutes) and the last (i.e., 5th) minute of SNSa stimulation for ultra-short-term parameters. Analysis of intra-individual changes revealed some heterogeneity in responses. The study provides baseline responses of HR, RespRate, and time-domain HRV parameters to SNSa stimulation among elite pentathlonists, which may be useful for identifying abnormal responses among fatigued or injured (e.g., concussed) athletes. More attention to individual analysis seems to be necessary when assessing physiological responses to sympathetic stimuli in professional endurance athletes.
Background and PurposeMost studies on heart rate variability (HRV) in professional athletes concerned linear, time-, and frequency-domain indices, and there is lack of studies on non-linear parameters in this group. The study aimed to determine the inter-day reliability, and group-related and individual changes of short-term symbolic dynamics (SymDyn) measures during sympathetic nervous system activity (SNSa) stimulation among elite modern pentathletes.MethodsShort-term electrocardiographic recordings were performed in stable measurement conditions with a 7-day interval between tests. SNSa stimulation via isometric handgrip strength test was conducted on the second day of study. The occurrence rate of patterns without variations (0V), with one variation (1V), two like (2LV), and two unlike variations (2UV) obtained using three approaches (the Max–min, the σ, and the Equal-probability methods) were analyzed. Relative and absolute reliability were evaluated.ResultsAll SymDyn indices obtained using the Max–min method, 0V, and 2UV obtained using the σ method, 2UV obtained using the Equal-probability method presented acceptable inter-day reliability (the intraclass correlation coefficient between .91 and .99, Cohen’s d between −.08 and .10, the within-subject coefficient of variation between 4% and 22%). 2LV, 2UV, and 0V obtained using the Max–min and σ methods significantly decreased and increased, respectively, during SNSa stimulation—such changes were noted for all athletes. There was no significant association between differences in SymDyn parameters and respiratory rate in stable conditions and while comparing stable conditions and SNSa stimulation.ConclusionSymDyn indices may be used as reliable non-respiratory-associated parameters in laboratory settings to detect autonomic nervous system (ANS) activity modulations in elite endurance athletes. These findings provide a potential solution for addressing the confounding influence of respiration frequency on HRV-derived inferences of cardiac autonomic function. For this reason, SymDyn may prove to be preferable for field-based monitoring where measurements are unsupervised.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.