The Emognition dataset is dedicated to testing methods for emotion recognition (ER) from physiological responses and facial expressions. We collected data from 43 participants who watched short film clips eliciting nine discrete emotions: amusement, awe, enthusiasm, liking, surprise, anger, disgust, fear, and sadness. Three wearables were used to record physiological data: EEG, BVP (2x), HR, EDA, SKT, ACC (3x), and GYRO (2x); in parallel with the upper-body videos. After each film clip, participants completed two types of self-reports: (1) related to nine discrete emotions and (2) three affective dimensions: valence, arousal, and motivation. The obtained data facilitates various ER approaches, e.g., multimodal ER, EEG- vs. cardiovascular-based ER, discrete to dimensional representation transitions. The technical validation indicated that watching film clips elicited the targeted emotions. It also supported signals’ high quality.
Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts pulse rate variability (PRV). This study aims to identify the nature of such artifacts caused by various types of factors under the conditions of precisely planned experiments. We also propose methods for their reduction based solely on the PPG signal while preserving the frequency content of PRV. The accuracy of PRV derived from PPG was compared to heart rate variability (HRV) derived from the accompanying ECG. The results indicate that filtering PPG signals using the discrete wavelet transform and its inverse (DWT/IDWT) is suitable for removing slow components and high-frequency noise. Moreover, the main benefit of amplitude demodulation is better preparation of the PPG to determine the duration of pulse cycles and reduce the impact of some other artifacts. Post-processing applied to HRV and PRV indicates that the correction of outliers based on local statistical measures of signals and the autoregressive (AR) model is only important when the PPG is of low quality and has no effect under good signal quality. The main conclusion is that the DWT/IDWT, followed by amplitude demodulation, enables the proper preparation of the PPG signal for the subsequent use of PRV extraction algorithms, particularly at rest. However, post-processing in the proposed form should be applied more in the situations of observed strong artifacts than in motionless laboratory experiments.
Cardiac monitoring based on wearable photoplethysmography (PPG) is widespread because of its usability and low cost. Unfortunately, PPG is negatively affected by various types of disruptions, which could introduce errors to the algorithm that extracts Pulse Rate Variability (PRV). This study aims to identify the nature of such artifacts caused by various types of factors under the conditions of precisely planned experiments. We also propose methods for their reduction based solely on the PPG signal while preserving the frequency content of PRV. The accuracy of PRV derived from PPG was compared to Heart Rate Variability (HRV) derived from the accompanying recorded ECG. The results indicate that filtering PPG signals using the Discrete Wavelet Transform and its inverse (DWT/IDWT) is suitable for removing slow components and high-frequency noise. Moreover, the main benefit of amplitude demodulation is better preparation of the PPG to determine the duration of pulse cycles and reduce the impact of some other artifacts. Postprocessing applied to HRV and PRV indicates that the correction of outliers based on local statistical measures of signals and the AR model is only important when PPG is of low-quality and has no effect under good signal quality. The main conclusion is that DWT/IDWT, followed by amplitude demodulation, enables the proper preparation of the PPG signal for the subsequent use of PRV extraction algorithms. However, postprocessing in the proposed form should be applied more in the situations of observed strong artifacts than in motionless laboratory experiments.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.