Feasibility of detecting intravascular flow using a catheter based endovascular
optical coherence tomography (OCT) system is demonstrated in a porcine carotid
model in vivo. The effects of A-line density, radial distance,
signal-to-noise ratio, non-uniform rotational distortion (NURD), phase stability
of the swept wavelength laser and interferometer system on Doppler shift
detection limit were investigated in stationary and flow phantoms. Techniques
for NURD induced phase shift artifact removal were developed by tracking the
catheter sheath. Detection of high flow velocity (~51 cm/s) present in the
porcine carotid artery was obtained by phase unwrapping techniques and compared
to numerical simulation, taking into consideration flow profile distortion by
the eccentrically positioned imaging catheter. Using diluted blood in saline
mixture as clearing agent, simultaneous Doppler OCT imaging of intravascular
flow and structural OCT imaging of the carotid artery wall was feasible. To our
knowledge, this is the first in vivo demonstration of Doppler
imaging and absolute measurement of intravascular flow using a rotating fiber
catheter in carotid artery.
Abstract. Optical coherence elastography (OCE) provides deformation or material properties, mapping of soft tissue. We aim to develop a robust speckle tracking OCE technique with improved resolution and accuracy. A digital image correlation (DIC)-based OCE technique was developed by combining an advanced DIC algorithm with optical coherence tomography (OCT). System calibration and measurement error evaluation demonstrated that this DIC-based OCE technique had a resolution of ∼0.6 μm displacement and <0.5% strain measurement in the axial scan direction. The measured displacement ranged from 0.6 to 150 μm, obtained via phantom imaging. The capability of the DIC-based OCE technique, for differentiation of stiffness, was evaluated by imaging a candle gel phantom with an irregularly shaped stiff inclusion. OCE imaging of a chicken breast sample differentiated the fat, membrane, and muscle layers. Strain elastograms of an aneurysm sample showed heterogeneity of the tissue and clear contrast between the adventitia and media. These promising results demonstrated the capability of the DIC-based OCE for the characterization of the various components of the tissue sample. Further improvement of the system will be conducted to make this OCE technique a practical tool for measuring and differentiating material properties of soft tissue.
Real-time depth metrology during material removal via laser ablation is useful in many forms of laser machining. Until now, coaxial optical coherence tomography (OCT) metrology was achieved by the coupling of an OCT imaging beam and ablating beams using a dichroic filter. We present an alternative design with all fiber delivery that is more suitable for surgical laser ablation applications. The novel system design integrates a high peak-power pulsed Yb-doped fiber laser (1064nm) coupled directly into the sample arm of a swept-source OCT system (λ c = 1310nm). We measured the OCT signal degradation due to dispersion and attenuation through the ablation fiber laser cavity. Ablation progression is measured in real-time using M-mode OCT. The mean depth targeting error was found to range from 10µm to 80µm in phantom ablation experiments and 21µm to 60µm in bone ablation. A number of issues have been solved, including point-spread function (PSF) peak broadening due to signal delay and dispersion, high bending loss due to dissimilar fiber used throughout the design, and problems due to the extremely high ablation power to swept-source power ratio (> 2x10 4 peak to average power). To our knowledge, this is the first demonstration of thermal-mediated laser ablation drilling integrated with coaxial OCT imaging through a single-mode, single-cladded output fiber, without using dichroic beam splitters or free-space optic filters anywhere in the optical path and with this high ablation laser power to OCT source power ratio. The removal of bulk optics compared to existing designs opens a new path for compact integration of the entire system. Also, since the ablation laser and OCT feedback system exist along the same fiber path, the need for maintenance and repair are greatly reduced since spatial beam alignment and the potential open-air contamination of optical surfaces are virtually eliminated. We believe that this integrated system is a great candidate for adoption in depth-controlled surgical ablation applications.
Application of speckle variance optical coherence tomography (OCT) to endovascular imaging faces difficulty of extensive motion artifacts inherently associated with arterial pulsations in addition to other physiological movements. In this study, we employed a technique involving a fourth order statistical method, kurtosis, operating on the endovascular OCT intensity images to visualize the vasa vasorum of carotid artery in vivo and identify its flow dynamic in a porcine model. The intensity kurtosis technique can distinguish vasa vasorum from the surrounding tissues in the presence of extensive time varying noises and dynamic motions of the arterial wall. Imaging of vasa vasorum and its proliferation, may compliment the growing knowledge of structural endovascular OCT in assessment and treatment of atherosclerosis in coronary and carotid arteries.
A prototype intraoperative hand-held optical coherence tomography (OCT) imaging probe was developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic probe was designed based on electrostatically driven optical fibers, and packaged into a catheter probe in the form factor of clinically accepted Bayonet shaped neurosurgical probes. Optical properties of the probe were measured to have a ~20 μm spot size, 5 mm working distance and 4 mm field of view. Feasibility of this probe for structural and Doppler shift imaging was tested on porcine femoral blood vessel imaging.
This study presents the design of a system used to monitor laser ablation in real-time using Optical Coherence Tomography (OCT). The design of the system involves a high-powered fiber laser (wavelength of 1064nm, 1kW peak power) being built directly into the sample arm of the OCT system (center wavelength 1310). It is shown that the OCT laser light and subsequent backscatter pass relatively unaffected through the fiber laser. Initial results are presented showing monitoring of the ablation process at a single point in real time using m-mode imaging.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.