Neuraxial analgesia in early labor did not increase the rate of cesarean delivery, and it provided better analgesia and resulted in a shorter duration of labor than systemic analgesia.
Bolus injection through an epidural catheter may result in better distribution of anesthetic solution in the epidural space compared with continuous infusion of the same anesthetic solution. In this randomized, double-blind study we compared total bupivacaine consumption, need for supplemental epidural analgesia, quality of analgesia, and patient satisfaction in women who received programmed intermittent epidural boluses (PIEB) compared with continuous epidural infusion (CEI) for maintenance of labor analgesia. The primary outcome variable was bupivacaine consumption per hour of analgesia. Combined spinal epidural analgesia was initiated in multiparas scheduled for induction of labor with cervical dilation between 2 and 5 cm. Subjects were randomized to PIEB (6-mL bolus every 30 min beginning 45 min after the intrathecal injection) or CEI (12-mL/h infusion beginning 15 min the after the intrathecal injection). The epidural analgesia solution was bupivacaine 0.625 mg/mL and fentanyl 2 microg/mL. Breakthrough pain in both groups was treated initially with patient-controlled epidural analgesia (PCEA) followed by manual bolus rescue analgesia using bupivacaine 0.125%. The median total bupivacaine dose per hour of analgesia was less in the PIEB (n = 63) (10.5 mg/h; 95% confidence interval, 9.5-11.8 mg/h) compared with the CEI group (n = 63) (12.3 mg/h; 95% confidence interval, 10.5-14.0 mg/h) (P < 0.01), fewer manual rescue boluses were required (rate difference 22%, 95% confidence interval of difference 5% to 38%), and satisfaction scores were higher. Labor pain, PCEA requests, and delivered PCEA doses did not differ. PIEB combined with PCEA provided similar analgesia, but with a smaller bupivacaine dose and better patient satisfaction compared with CEI with PCEA for maintenance of epidural labor analgesia.
Objective
The mechanisms leading to worse outcomes in African-American (AA) women with preeclampsia/eclampsia remain unclear. Our objective was to identify racial differences in maternal comorbidities, peripartum characteristics, and maternal and fetal outcomes.
Methods/Results
When compared to white women with preeclampsia/eclampsia, AA women had an increased unadjusted risk of inpatient maternal mortality (OR 3.70, 95% CI: 2.19-6.24). After adjustment for covariates, in-hospital mortality for AA women remained higher than that for white women (OR 2.85, 95% CI: 1.38-5.53), while, the adjusted risk of death among Hispanic women did not differ from that for white women. We also found an increased risk of intrauterine fetal death (IUFD) among AA women. When compared to white women with preeclampsia, AA women had an increased unadjusted odds of IUFD (OR 2.78, 95% CI: 2.49-3.11), which remained significant after adjustment for covariates (adjusted OR 2.45, 95% CI: 2.14-2.82). In contrast, IUFD among Hispanic women did not differ from that for white women after adjusting for covariates.
Conclusions and Relevance
Our data suggest that African American women are more likely to have risk factors for preeclampsia and more likely to suffer an adverse outcome during peripartum care. Future research should examine whether controlling co-morbidities and other risk factors will help to alleviate racial disparities in outcomes in this cohort of women.
Hemorrhage is the most frequent cause of severe maternal morbidity and preventable maternal mortality and therefore is an ideal topic for the initial national maternity patient safety bundle. These safety bundles outline critical clinical practices that should be implemented in every maternity unit. They are developed by multidisciplinary work groups of the National Partnership for Maternal Safety under the guidance of the Council on Patient Safety in Women's Health Care. The safety bundle is organized into 4 domains: Readiness, Recognition and Prevention, Response, and Reporting and Systems Learning. Although the bundle components may be adapted to meet the resources available in individual facilities, standardization within an institution is strongly encouraged. References contain sample resources and "Potential Best Practices" to assist with implementation.
A decrease in the incidence of PDPH or the need for criteria-directed therapeutic epidural patch was not detected when a prophylactic epidural blood patch was administered to parturients after inadvertent dural puncture. However, prophylactic epidural blood patch did shorten the duration of PDPH symptoms.
The estimated incidence of postpartum nerve injury was greater than reported from previous studies and is associated with nulliparity and prolonged second stage of labor.
The developed scoring tool to measure resident performance of general anesthesia for emergency cesarean delivery on the patient simulator seems both valid and reliable in the context in which it was tested. This scoring system may prove useful for future studies such as those investigating the effect of simulator training on objective assessment of resident performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.