In this article, we demonstrate the new method of pulsed interleaved excitation (PIE), which can be used to extend the capabilities of multiple-color fluorescence imaging, fluorescence cross-correlation spectroscopy (FCCS), and single-pair fluorescence resonance energy transfer (spFRET) measurements. In PIE, multiple excitation sources are interleaved such that the fluorescence emission generated from one pulse is complete before the next excitation pulse arrives. Hence, the excitation source for each detected photon is known. Typical repetition rates used for PIE are between approximately 1 and 50 MHz. PIE has many applications in various fluorescence methods. Using PIE, dual-color measurements can be performed with a single detector. In fluorescence imaging with multicolor detection, spectral cross talk can be removed, improving the contrast of the image. Using PIE with FCCS, we can eliminate spectral cross talk, making the method sensitive to weaker interactions. FCCS measurements with complexes that undergo FRET can be analyzed quantitatively. Under specific conditions, the FRET efficiency can be determined directly from the amplitude of the measured correlation functions without any calibration factors. We also show the application of PIE to spFRET measurements, where complexes that have low FRET efficiency can be distinguished from those that do not have an active acceptor.
The GroEL/GroES chaperonin system mediates protein folding in the bacterial cytosol. Newly synthesized proteins reach GroEL via transfer from upstream chaperones such as DnaK/DnaJ (Hsp70). Here we employed single molecule and ensemble FRET to monitor the conformational transitions of a model substrate as it proceeds along this chaperone pathway. We find that DnaK/DnaJ stabilizes the protein in collapsed states that fold exceedingly slowly. Transfer to GroEL results in unfolding, with a fraction of molecules reaching locally highly expanded conformations. ATP-induced domain movements in GroEL cause transient further unfolding and rapid mobilization of protein segments with moderate hydrophobicity, allowing partial compaction on the GroEL surface. The more hydrophobic regions are released upon subsequent protein encapsulation in the central GroEL cavity by GroES, completing compaction and allowing rapid folding. Segmental chain release and compaction may be important in avoiding misfolding by proteins that fail to fold efficiently through spontaneous hydrophobic collapse.
A new terrylene diimide-based dye (WS-TDI) that is soluble in water has been synthesized, and its photophysical properties are characterized. WS-TDI forms nonfluorescing H-aggregates in water that show absorption bands being blue-shifted with respect to those of the fluorescing monomeric form. The ratio of monomeric WS-TDI to aggregated WS-TDI was determined to be 1 in 14 400 from fluorescence correlation spectroscopy (FCS) measurements, suggesting the presence of a large amount of soluble, nonfluorescent aggregates in water. The presence of a surfactant such as Pluronic P123 or CTAB leads to the disruption of the aggregates due to the formation of monomers in micelles. This is accompanied by a strong increase in fluorescence. A single molecule study of WS-TDI in polymeric films of PVA and PMMA reveals excellent photostability with respect to photobleaching, far above the photostability of other common water-soluble dyes, such as oxazine-1, sulforhodamine-B, and a water-soluble perylenediimide derivative. Furthermore, labeling of a single protein such as avidin is demonstrated by FCS and single molecule photostability measurements. The high tendency of WS-TDI to form nonfluorescent aggregates in water in connection with its high affinity to lipophilic environments is used for the fluorescence labeling of lipid membranes and membrane containing compartments such as artificial liposomes or endosomes in living HeLa cells. The superior fluorescence imaging quality of WS-TDI in such applications is demonstrated in comparison to other well-known membrane staining dyes such as Alexa647 conjugated with dextran and FM 4-64 lipophilic styryl dye.
The self-assembly properties of DNA make it an ideal choice for the construction of nanomachines such as DNA tweezers. Because nanomachines function as individual units, they need to be studied on the single-molecule level. From single-pair FRET investigations, we show that "open" tweezers exist in a single conformation with minimal FRET efficiency, whereas upon addition of a "closing strand", three conformations are observed, which are averaged out in ensemble measurements.
The development of nanobiotechnological devices requires the ability to build various components with nanometer accuracy. DNA is a well-established nanoscale building block that self assembles due to specific interactions that are encoded in its sequence. Recently, it has become possible to couple proteins to DNA, thereby expanding the capabilities of DNA for use with molecular photonics and bioelectronics. Here, we present the design and characterization of a supramolecular Förster resonance energy transfer (FRET) system by using a fluorescent protein bound to single-stranded DNA (ssDNA), a fluorophore attached to a second ssDNA molecule, and a complementary strand for hybridizing the two fluorophores together. The FRET efficiency was studied by using both ensemble and single-pair FRET measurements. The distance between the two fluorophores was determined from the single-pair FRET efficiency and could be described by a simple cylindrical model for the DNA. Hence, DNA can be used as a scaffold for positioning fluorescent proteins, as well as traditional fluorophores, with nanometer accuracy and shows great potential for use in the future of nanobiotechnology.
In this study we present a refined optical detection technique for investigation of fast reactions based on confocal fluorescence spectroscopy in a miniaturized continuous flow (mCF) reactor. The special setup allows for simultaneous observation of the reaction on the basis of fluorescent resonance energy transfer (FRET) as an indicator of the reaction progress. Determination of the flow velocity via spatial fluorescence cross-correlation enables the conversion of spatial information, i.e. the position of the detection point, into the respective temporal information. To overcome the disadvantage of conventional continuous flow reactors of high sample consumption, we used a microfluidic chip allowing an economical expenditure of sample solution at low concentration, while the silicon/glass chip is perfectly adaptable to the confocal setup. Inside these channels, rapid, diffusion-based mixing under laminar flow conditions is performed at the crossing of three channels by squeezing the solutions into thin layers. Using this mCF device, we investigated the irreversible cleavage reaction of a double stranded DNA oligomer by the enzyme exonuclease III. The complementary DNA strands are stained with TAMRA and Cy 5 dye molecules, respectively, undergoing an energy transfer if both strands are annealed. The reduction of the Cy 5 fluorescence directly corresponds to the progress of the cleavage reaction.
Fluorescence correlation spectroscopy (FCS) and fluorescence cross-correlation spectroscopy (FCCS) are methods that extract information about a sample from the influence of thermodynamic equilibrium fluctuations on the fluorescence intensity. This method allows dynamic information to be obtained from steady state equilibrium measurements and its popularity has dramatically increased in the last 10 years due to the development of high sensitivity detectors and its combination with confocal microscopy. Using time-correlated single-photon counting (TCSPC) detection and pulsed excitation, information over the duration of the excited state can be extracted and incorporated in the analysis. In this short review, we discuss new methodologies that have recently emerged which incorporated fluorescence lifetime information or TCSPC data in the FCS and FCCS analysis. Time-gated FCS discriminates between which photons are to be incorporated in the analysis dependent upon their arrival time after excitation. This allows for accurate FCS measurements in the presence of fluorescent background, determination of sample homogeneity, and the ability to distinguish between static and dynamic heterogeneities. A similar method, time-resolved FCS can be used to resolve the individual correlation functions from multiple fluorophores through the different fluorescence lifetimes. Pulsed interleaved excitation (PIE) encodes the excitation source into the TCSPC data. PIE can be used to perform dual-channel FCCS with a single detector and allows elimination of spectral cross-talk with dual-channel detection. For samples that undergo fluorescence resonance energy transfer (FRET), quantitative FCCS measurements can be performed in spite of the FRET and the static FRET efficiency can be determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.