Experimental and computational studies were performed to elucidate the role of turbulent stresses in mechanical blood damage (hemolysis). A suspension of bovine red blood cells (RBC) was driven through a closed circulating loop by a centrifugal pump. A small capillary tube (inner diameter 1 mm and length 70 mm) was incorporated into the circulating loop via tapered connectors. The suspension of RBCs was diluted with saline to achieve an asymptotic apparent viscosity of 2.0 +/- 0.1 cP at 23 degrees C to produce turbulent flow at nominal flow rate and pressure. To study laminar flow at the identical wall shear stresses in the same capillary tube, the apparent viscosity of the RBC suspension was increased to 6.3 +/- 0.1 cP (at 23 degrees C) by addition of Dextran-40. Using various combinations of driving pressure and Dextran mediated adjustments in dynamic viscosity Reynolds numbers ranging from 300-5,000 were generated, and rates of hemolysis were measured. Pilot studies were performed to verify that the suspension media did not affect mechanical fragility of the RBCs. The results of these bench studies demonstrated that, at the same wall shear stress in a capillary tube, the level of hemolysis was significantly greater (p < 0.05) for turbulent flow as compared with laminar flow. This confirmed that turbulent stresses contribute strongly to blood mechanical trauma. Numerical predictions of hemolysis obtained by computational fluid dynamic modeling were in good agreement with these experimental data.
Mechanical damage to blood cells is of considerable concern in the development and use of circulatory assist devices and other blood contacting systems. Furthermore, hemodilution with saline, dextran, and other plasma expanders applied during extracorporeal circulation and dialysis increases red blood cell (RBC) susceptibility to the high shear stresses associated with these procedures. In this paper, we present polyethylene glycol (PEG) as a potential erythrocyte protective agent against mechanically induced cellular trauma. Bovine RBCs were subjected to mechanical stress induced by rolling stainless steel shots through RBC suspensions for a constant exposure time. The suspensions were prepared at a hematocrit of 30% in various media: PEG (20,000 molecular weight), autologous bovine plasma, Dextran 40 solution, and phosphate buffered saline (PBS). RBC suspensions in Dextran 40 were prepared at a viscosity similar to the PEG suspensions. We found the hemolysis level of RBCs suspended in plasma and in PEG solutions to be several times lower (p < 0.001) than in the Dextran and PBS solutions. No statistically significant difference was found between the hemolysis that occurred in suspensions of RBCs in autologous plasma and in 2.0% PEG solutions. Even PEG concentration as low as 0.1% reduced hemolysis by more than 40% compared with PBS or the same concentration of Dextran in suspension medium. Our data demonstrate the efficacy of PEG molecules in reducing mechanical trauma to erythrocytes and suggest the potential for using PEG in assisted circulation, dialysis, and other procedures where RBCs are subjected to extensive mechanical stress.
Administration of nanomolar concentrations of aloe vera-based DRP prolonged survival time in animals with AMI. DRPs may offer a novel method to treat organ/tissue hypoperfusion.
Hemodialysis requires reliable frequent access to the patients' vasculature, with blood flow rates of > 300 ml/min. Currently in the U.S. market, there are three types of hemodialysis access systems: the native arteriovenous fistula, generally using 15G needles; the synthetic arteriovenous (AV) graft, also generally using 15G needles; and the percutaneous catheter. Some of the problems with current vascular access technologies include insufficient blood flow, blood trauma, thrombosis, infection, cardiac load, and venous stenosis. The LifeSite System (Vasca, Inc.) represents an alternative for vascular access, and consists of a subcutaneous valve and 12F cannula accessed by a standard 14G needle. The LifeSite valve is implanted in the upper torso with the cannula generally entering the right internal jugular vein. The purpose of this study was to compare the LifeSite System with two known vascular access systems: the 10F dialysis catheter (Tesio-Cath, MedComp) and the 15G A.V. Fistula Needle Set (JMS Co., Ltd.) with regard to blood damage produced by these devices in use. Mechanical hemolysis and sublethal blood trauma were evaluated by means of in vitro blood pumping through a circulating loop incorporating a hemodialysis vascular access system. Sublethal blood damage was examined by using a hemorheologic assay that included parameters such as erythrocyte mechanical fragility, plasma total protein and fibrinogen concentrations, and blood viscosity. The tests demonstrated that, at both studied flow rates of 300 ml/min and 450 ml/min, the LifeSite produced lower hemolysis and less sublethal damage to blood than either the Tesio-Cath catheter or the A.V. Fistula Needle Set.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.