Abstract-Technological development in the area of wireless communications lead to the requirement of tight integration of both the digital and analog functional units. Integrating mixers is a challenging task, especially in mixed signal design. IoT communication devices require low design complexity as we expect millions of devices connected. In this paper we propose a mixer less low complex QPSK based transmitter architecture targeting low frequency applications which reduced the complexity in transmitter design. A prototype has been developed using Bipolar Junction Transistors (BJTs) and FPGA as the base band controller. The design can easily be adapted to MOSFET technology and modulation is achieved without the need of generating the carrier externally. The prototype developed was tested successfully by generating frequencies of range varying from 1 KHz to 120 MHz. The proposed architecture can also be used for any other digital modulation scheme such as BPSK, FSK etc.
In this letter, we propose two novel methods for four-class motor imagery (MI) classification using electroencephalography (EEG). Also, we developed a real-time health 4.0 (H4.0) architecture for brain-controlled internet of things (IoT) enabled environments (BCE), which uses the classified MI task to assist disabled persons in controlling IoT-enabled environments such as lighting and heating, ventilation, and air-conditioning (HVAC). The first method for classification involves a simple and low-complex classification framework using a combination of regularized Riemannian mean (RRM) and linear SVM. Although this method performs better compared to state-of-the-art techniques, it still suffers from a nonnegligible misclassification rate. Hence, to overcome this, the second method offers a persistent decision engine (PDE) for the MI classification, which improves classification accuracy (CA) significantly. The proposed methods are validated using an in-house recorded four-class MI data set (data set I, collected over 14 subjects), and a four-class MI data set 2a of BCI competition IV (data set II, collected over 9 subjects). The proposed RRM architecture obtained average CAs of 74.30% and 67.60% when validated using datasets I and II, respectively. When analyzed along with the proposed PDE classification framework, an average CA of 92.25% on 12 subjects of data set I and 82.54% on 7 subjects of data set II is obtained. The results show that the PDE algorithm is more reliable for the classification of four-class MI and is also feasible for BCE applications. The proposed low-complex BCE architecture is implemented in real time using Raspberry Pi 3 Model B+ along with the Virgo EEG data acquisition system. The hardware implementation results show that the proposed system architecture is well suited for body-wearable devices in the scenario of Health 4.0. We strongly feel that this study can aid in driving the future scope of BCE research.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.