Background. In a study of normal and abnormal growth of the aorta before birth, high-resolution echocardiographic imaging of the aortic arch in 92 normal fetuses aged 16-38 weeks was used to establish normal values for aortic arch dimensions at varying gestational ages.Methods and Results. From long-axis views of the aortic arch, the internal diameter of the aortic root, ascending aorta, transverse aortic arch, aortic isthmus, proximal descending thoracic aorta, and left common carotid artery were measured. Correlation coefficients for the diameter of each aortic arch segment when related to gestational age varied from r=0.87 to r=0.94 (p<0.001 for each), and growth
Our efforts indicate that transvascular passage of small phased-array probes can be easily accomplished and is a promising technique for detailed visualization of cardiac structures. This approach may provide an alternative to transesophageal echocardiography, particularly for guiding interventional procedures such as placement of transcatheter closure devices in pediatric patients.
An accurate but simple and noninvasive method for quantifying flow across a ventricular septal defect has yet to be implemented for routine clinical use. A region of flow convergence is commonly imaged by Doppler color flow mapping on the left septal surface of the ventricular septal defect, appearing as a narrowed region of laminar flow with aliased flow velocities entering the orifice. If the first aliasing region represents a hemispheric isovelocity boundary of a surface of flow convergence and all flow at this surface crosses the ventricular septal defect, the flow through the defect can be estimated by using the radius (R), measured from the first alias to the orifice, and the Nyquist limit (NL) velocity (the flow velocity at the first alias). Doppler color flow imaging was performed in 18 children with a single membranous ventricular septal defect undergoing cardiac catheterization at a mean age of 29.8 months (Group I). Indexes of maximal flow rate across the defect were developed from either the radius or the area, obtained by planimetry, of the first alias, based on Doppler color flow images. All indexes were corrected for body surface area and compared with shunt flow (Qp-Qs) and pulmonary to systemic flow ratio (Qp/Qs) determined at cardiac catheterization. Doppler color flow indexes derived from images of flow convergence in both the long-axis (n = 15) and oblique four-chamber (n = 10) views correlated closely with Qp/Qs (r = 0.71 to 0.92) and Qp - Qs (r = 0.69 to 0.97).(ABSTRACT TRUNCATED AT 250 WORDS)
Anomalous origin of the left coronary artery from the pulmonary artery is a rare but important cause of congestive heart failure in infancy and of sudden death at all ages. Diagnosis is often missed when based solely on physical examination and noninvasive methods. A 4 year old patient is presented in whom mitral regurgitation was noted by a referring physician and an anomalous left coronary artery was found by Doppler color flow mapping upon referral and verified at cardiac catheterization. Doppler color flow mapping was also used intraoperatively using a gas-sterilized transducer to further clarify the hemodynamics and assess the surgical result. After creation of an intrapulmonary artery tunnel from the ostium of the left coronary artery to the aorta, anterograde coronary artery flow and absence of a residual left to right pulmonary artery shunt were verified during surgery by Doppler flow mapping. Postoperatively, residual mitral regurgitation and patency of the left coronary artery graft have been followed up serially by Doppler flow mapping. Therefore, Doppler color flow mapping is useful in the diagnosis and intraoperative and postoperative management of this important and potentially life-threatening abnormality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.