The encouraging results of the proposed technique could be of benefit in optimizing the reconstruction of large critical-size bone defects.
Superficial parotidectomy through facelift incision with immediate reconstruction with superiorly based partial thickness SCM flap allows adequate resection of most benign parotid tumors with a satisfactory aesthetic outcome and minimal donor site morbidity.
Introduction The cervical spine is a highly mobile segment of the spinal column, liable to a variety of diseases and susceptible to trauma. It is a complex region where many vital structures lie in close proximity. Lateral mass screw fixation has become the method of choice in stabilizing subaxial cervical spine among other posterior cervical fixation techniques whenever the posterior elements are absent or compromised. Objective This study examined cervical specimens of cadavers and cervical computed tomography (CT) scans to minimize as much as possible complications of cervical lateral mass screw placement such as vertebral artery or nerve root injuries, facet joint violations, or inadequate placement. Methods Forty normal cervical CT scans, obtained from the emergency unit as part of the trauma workup, were included in this study plus 10 cervical cadaveric specimens obtained from the Alexandria Neuro-anatomy laboratory. There were three fixed parameters for screw insertion in this study. First, the point of screw insertion was the midpoint of the lateral mass; it was the crossing point between the sagittal and axial planes of the posterior cortex of the lateral mass. Second, the direction of the screw in the craniocaudal plane was 30 degrees cranially to avoid facet joint penetration. Third, the exit point of the screw was located on the ventral cortex of the lateral mass just lateral to the root of the transverse process in the midaxial cut of each lateral mass, to make a sound bicortical fixation without injuring the vertebral artery or the nerve root. The selected screw trajectory in this study was the line drawn between the inlet and exit points. The depth and width of the lateral mass of the cervical vertebrae from C3 to C7 were measured as well as the angle of screw trajectory from the sagittal plane. All these measures were applied on the cadaveric specimens to make sure that no injury to the vertebral artery, nerve root, or facet joint occurred. Results As regards the collected measurements of the lateral mass of all subaxial cervical vertebrae, the study revealed that the average depth of the lateral mass was 12.83 ± 1.28 mm. The average width of the lateral mass was 11.92 ± 0.96 mm. The average divergent angle of bicortical screw insertion without injury to the vertebral artery or the nerve root was 19.51 ± 1.83 degrees. As regard the cadaveric specimens, based on all the collected measurements taken from the CT scans, there was no reported injury to the vertebral arteries or nerve roots or penetration to the facet joints. Conclusion Lateral mass fixation can be applied easily and safely for all levels of subaxial cervical spine from C3 to C6 with the following parameters: (1) the point of entry is the midpoint of the lateral mass; (2) the screw trajectory is directed 30 degrees cranially and 20 degrees laterally; (3) the screw length is 13 to 15 mm.
Background:Autologous breast reconstruction using the extended latissimus dorsi flap has been infrequently reported. In the current study, the authors are reporting their own clinical experience with this method. A review of the literature is also discussed.Materials and Methods:Over a three year period, 14 patients underwent breast reconstruction using the extended latissimus dorsi (LD) flap. Patients with small to medium sized breasts were selected. The age of the patients ranged from 29 to 42 years with a follow-up period ranging from six to 18 months. The indications, flap-related complications and donor site morbidity and aesthetic results were evaluated.Results:The main indication to use the flap was dorsal donor site preference by patients. The remaining patients were either not suitable for a flap from the abdomen or wished to get pregnant and were offered the dorsal donor site. Neither total nor partial flap loss was recorded but donor site morbidity was mainly due to seroma, which was treated conservatively in all patients, except for one who required surgery. Another two patients suffered from wound breakdown and distal necrosis of the back flaps. Mild contour deformity was also noted on the back of all patients but caused no major concern. Indeed, the overall patient satisfaction was very high.Conclusion:The extended LD flap proved to be a good option for autologous breast reconstruction in selected patients. Patients should be warned of the potential for seroma and mild contour back deformity.
BackgroundCurrent reconstructive techniques for continuity defects of the mandible include the use of free flaps, bone grafts, and alloplastic materials. New methods of regenerative medicine designed to restore tissues depend mainly on the so-called extrinsic neovascularization, where the neovascular bed originates from the periphery of the construct. This method is not applicable for large defects in irradiated fields.MethodsWe are introducing a new animal model for mandibular reconstruction using intrinsic axial vascularization by the Arterio-Venous (AV) loop. In order to test this model, we made cadaveric, mechanical loading, and surgical pilot studies on adult male goats. The cadaveric study aimed at defining the best vascular axis to be used in creating the AV loop in the mandibular region. Mechanical loading studies (3 points bending test) were done to ensure that the mechanical properties of the mandible were significantly affected by the designed defect, and to put a base line for further mechanical testing after bone regeneration. A pilot surgical study was done to ensure smooth operative and post operative procedures.ResultsThe best vascular axis to reconstruct defects in the posterior half of the mandible is the facial artery (average length 32.5 ± 1.9 mm, caliber 2.5 mm), and facial vein (average length 33.3 ± 1.8 mm, caliber 2.6 mm). Defects in the anterior half require an additional venous graft. The defect was shown to be significantly affecting the mechanical properties of the mandible (P value 0.0204). The animal was able to feed on soft diet from the 3rd postoperative day and returned to normal diet within a week. The mandible did not break during the period of follow up (2 months).ConclusionsOur model introduces the concept of axial vascularization of mandibular constructs. This model can be used to assess bone regeneration for large bony defects in irradiated fields. This is the first study to introduce the concept of axial vascularization using the AV loop for angiogenesis in the mandibular region. Moreover, this is the first study aiming at axial vascularization of synthetic tissue engineering constructs at the site of the defect without any need for tissue transfer (in contrast to what was done previously in prefabricated flaps).
Background: Autologous breast reconstruction using the extended latissimus dorsi flap has been infrequently reported. in the current study, the authors are reporting their own clinical experience with this method. a review of the literature is also discussed.Materials and methods: Over a three year period, 14 patients underwent breast reconstruction using the extended latissimus dorsi (ld) flap. patients with small to medium sized breasts were selected. the age of the patients ranged from 29 to 42 years with a follow-up period ranging from six to 18 months. the indications, flap-related complications and donor site morbidity and aesthetic results were evaluated.Results: The main indication to use the flap was dorsal donor site preference by patients. the remaining patients were either not suitable for a flap from the abdomen or wished to get pregnant and were offered the dorsal donor site. neither total nor partial flap loss was recorded but donor site morbidity was mainly due to seroma, which was treated conservatively in all patients, except for one who required surgery. another two patients suffered from wound breakdown and distal necrosis of the back flaps. mild contour deformity was also noted on the back of all patients but caused no major concern. indeed, the overall patient satisfaction was very high.Conclusion: The extended ld flap proved to be a good option for autologous breast reconstruction in selected patients. patients should be warned of the potential for seroma and mild contour back deformity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.