We studied the effect of abolishing cutaneous sensation (by infiltrating local anaesthetic around the median nerve at the wrist) on the ability of 10 healthy volunteers (a) to maintain a submaximal isometric pinch-grip force for 30 s without visual feedback, and (b) to perform a fine finger-manipulation 'handwriting' task. Blocking cutaneous sensation had no effect on ability to maintain pinch force, suggesting that muscle afferents have the major role in force-control feedback. However, a near-linear fall in force, present with or without block (mean slope = -1.3 & 0.2%) s-'), which cannot be attributed to motor fatigue, reveals a shortcoming of the afferent feedback system. Blocking cutaneous sensation did impair ability to perform the more demanding writing task, as judged by an 18 2 6% increase in the length of the path between target points, a 22 k 9% increase in the duration of the movement and a 63 k 24% in 'normalised averaged rectified jerk', an averaged time-derivative of acceleration (all significantly nonzero, P < 0.04).These experiments demonstrate the relative importance of muscular and cutaneous afferent feedback on two aspects of hand performance, and provide a way to quantify the deficit resulting from the lack of cutaneous sensation. Crown
A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (sd 2.1). The mean pre-operative femoral offset for these hips was 41 mm (sd 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon. At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (sd 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.