Diagnostic reference levels (DRLs) are critical operational standards for monitoring radiological imaging parameters and ensuring patient safety in hospitals. A regular review of DRLs is necessary to optimize scanners and protocol parameters. This retrospective study collected data on the CT dose index volume and dose–length product for 250 children who underwent head CT scans in the region of Abu Dhabi, United Arab Emirates. Descriptive statistics were used to present median, range, and interquartile range values for each pediatric age group, based on region and protocol. The 75th percentile was used as the reference point for local DRLs. Proposed values of DRLs were suggested per age groups; 304 mGy∙cm (children < 1 year), 385 mGy∙cm (children ≥ 1 year to <5 years), 441 mGy∙cm (children ≥ 5 years to <10 years), and 568 mGy∙cm (patients ≥ 10 years to <16 years. A comparison of the local DRLs with previously established ones was carried out, and differences were discussed. To the best of our knowledge, this is the first study on pediatric head CT scans in this region. We believe the results can be used as a baseline for establishing local DRLs in the Emirate of Abu Dhabi and national DRLs in the United Arab Emirates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.