CSH is associated with a significantly increased risk of infection requiring hospitalization within 1 year following cardiac implantable electronic device surgery. Strategies aimed at reducing hematomas may decrease the long-term risk of infection. (Bridge or Continue Coumadin for Device Surgery Randomized Controlled Trial [BRUISE CONTROL]; NCT00800137).
Objectives-To conduct a clinical, genetic and functional analysis of three unrelated families with familial sinus bradycardia (FSB).Background-Mutations in the hyperpolarization-activated nucleotide-gated channel (HCN4) are known to be associated with FSB.
Coronavirus disease 2019 (Covid-19) is associated with high incidence of venous and arterial thromboembolic events. Currently, there are no markers to guide antithrombotic therapy in Covid-19. Immature platelets represent a population of hyper-reactive platelets associated with arterial events. This prospective study compared consecutive Covid-19 patients (n = 47, median age = 56 years) to patients with acute myocardial infarction (AMI, n = 100, median age = 59 years) and a group of stable patients with cardiovascular risk factors (n = 64, median age = 68 years). Immature platelet fraction (IPF) and immature platelet count (IPC) were determined by the Sysmex XN-3000 auto-analyzer on admission and at subsequent time-points. IPF% on admission was higher in Covid-19 than the stable group and similar to the AMI group (4.8% [IQR 3.4-6.9], 3.5% [2.7-5.1], 4.55% [3.0-6.75], respectively, p = 0.0053). IPC on admission was also higher in Covid-19 than the stable group and similar to the
Background:
Polymorphic ventricular tachycardia (VT) without QT prolongation is well described in patients without structural heart disease (mainly idiopathic ventricular fibrillation and Brugada syndrome) and in patients with acute ST-elevation myocardial infarction.
Methods:
Retrospective study of patients with polymorphic VT related to coronary artery disease, but without evidence of acute myocardial ischemia.
Results:
The authors identified 43 patients in whom polymorphic VT developed within days of an otherwise uncomplicated myocardial infarction or coronary revascularization procedure. The polymorphic VT events were invariably triggered by extrasystoles with short (364±36 ms) coupling interval. Arrhythmic storms (4–16 events of polymorphic VT deteriorating to ventricular fibrillation) occurred in 23 (53%) patients. These arrhythmic storms were always refractory to conventional antiarrhythmic therapy, including intravenous amiodarone, but invariably responded to quinidine therapy. In-hospital mortality was 17% for patients with arrhythmic storm. Patients treated with quinidine invariably survived to hospital discharge. During long-term follow-up (of 5.6±6 years; range, 1 month to 18 years), 3 (16%) of patients discharged without quinidine developed recurrent polymorphic VT. There were no recurrent arrhythmias during quinidine therapy
Conclusions:
Arrhythmic storm with recurrent polymorphic VT in patients with coronary disease responds to quinidine therapy when other antiarrhythmic drugs (including intravenous amiodarone) fail.
Aims
Distinctive types of polymorphic ventricular tachycardia (VT) respond differently to different forms of therapy. We therefore performed the present study to define the electrocardiographic characteristics of different forms of polymorphic VT.
Methods and results
We studied 190 patients for whom the onset of 305 polymorphic VT events was available. The study group included 87 patients with coronary artery disease who had spontaneous polymorphic VT triggered by short-coupled extrasystoles in the absence of myocardial ischaemia. This group included 32 patients who had a long QT interval but nevertheless had their polymorphic VT triggered by ectopic beats with short coupling interval, a subcategory termed ‘pseudo-torsade de pointes] (TdP). For comparison, we included 50 patients who had ventricular fibrillation (VF) during acute myocardial infarction (‘ischaemic VF’ group) and 53 patients with drug-induced TdP (‘true TdP’ group). The QT of patients with pseudo-TdP was (by definition) longer than that of patients with polymorphic VT and normal QT (QTc 491.4 ± 25.2 ms vs. 447.3 ± 55.6 ms, P < 0.001). However, their QT was significantly shorter than that of patients with true TdP (QTc 564.6 ± 75.6 ms, P < 0.001). Importantly, the coupling interval of the ectopic beat triggering the arrhythmia was just as short during pseudo-TdP as during polymorphic VT with normal QT (359.1 ± 38.1 ms vs. 356.6 ± 39.4 ms, P = 0.467) but was much shorter than during true TdP (581.2 ± 95.3 ms, P < 0.001).
Conclusions
The coupling interval helps discriminate between polymorphic VT that occurs despite a long QT interval (pseudo-TdP) and polymorphic arrhythmias striking because of a long QT (true TdP).
RT3DTEE method is more accurate than 2DTEE for assessment of maximal LAA orifice diameter. Bedsides, RT3DTEE LAA measurements are not statistically different from CT. Thus, RT3DTEE may facilitate LAA closure procedure by choosing the appropriate device size.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.