Aim:To develop a simple, accurate, sensitive, rapid and precise method for the determination of galantamine hydrobromide in bulk drug and pharmaceutical dosage form.Material and Methods:The method employs wavelength detection and determination of galantamine hydrobromide at excitation wavelength 282 nm and emission wavelength 607 nm in a solution of simple distilled water.Result and Conclusion:The method was found to be linear in the range of 2–14 μg/ml having r2 = 0.9999. The mean accuracy was found to be 98.12% to 99.67%. The intraday and interday precision was found to be 0.18–0.35% and 0.13–0.46%, respectively. The limit of detection was found to be 0.29 μg/ml. The limit of quantification was found to be 0.89 μg/ml. The method was successfully applied for the determination of galantamine hydrobromide in bulk drug as well as pharmaceutical dosage form.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.