This pilot study was designed to assess the efficacy of low-frequency repetitive transcranial magnetic stimulation (rTMS) over the right orbitofrontal cortex (OFC) by means of a double-cone coil in patients suffering from obsessive-compulsive disorder. We hypothesized that low-frequency stimulation of the OFC would lead to a reduction in clinical symptoms, as measured on the Yale-Brown Obsessive Compulsive Scale (Y-BOCS). A randomized, double-blind, crossover design was implemented with two 1-week treatment periods (active stimulation versus sham stimulation) separated by a 1-month washout period. Concomitantly, a subgroup of patients underwent a positron emission tomography (PET) scan after each stimulation sequence. Statistical analyses compared the Y-BOCS scores at the end of each period. At day 7, we observed a significant decrease from baseline in the Y-BOCS scores, after both active (P<0.01) and sham stimulation (P=0.02). This decrease tended to be larger after active stimulation than after sham stimulation: −6 (−29, 0) points versus −2 (−20, 4) points (P=0.07). Active versus sham PET scan contrasts showed that stimulation was related to a bilateral decrease in the metabolism of the OFC. The OFC should definitely be regarded as a key neuroanatomical target for rTMS, as it is easier to reach than either the striatum or the subthalamic nucleus, structures favored in neurosurgical approaches.
ObjectiveThe decrease in verbal fluency in patients with Parkinson’s disease (PD) undergoing subthalamic nucleus deep brain stimulation (STN-DBS) is usually assumed to reflect a frontal lobe-related cognitive dysfunction, although evidence for this is lacking.MethodsTo explore its underlying mechanisms, we combined neuropsychological, psychiatric and motor assessments with an examination of brain metabolism using F-18 fluorodeoxyglucose positron emission tomography, in 26 patients with PD, 3 months before and after surgery. We divided these patients into two groups, depending on whether or not they exhibited a postoperative deterioration in either phonemic (10 patients) or semantic (8 patients) fluency. We then compared the STN-DBS groups with and without verbal deterioration on changes in clinical measures and brain metabolism.ResultsWe did not find any neuropsychological change supporting the presence of an executive dysfunction in patients with a deficit in either phonemic or semantic fluency. Similarly, a comparison of patients with or without impaired fluency on brain metabolism failed to highlight any frontal areas involved in cognitive functions. However, greater changes in cognitive slowdown and apathy were observed in patients with a postoperative decrease in verbal fluency.ConclusionsThese results suggest that frontal lobe-related cognitive dysfunction could play only a minor role in the postoperative impairment of phonemic or semantic fluency, and that cognitive slowdown and apathy could have a more decisive influence. Furthermore, the phonemic and semantic impairments appeared to result from the disturbance of distinct mechanisms.
In medical imaging, the continuous quest to improve diagnostic performance and optimize treatment strategies has led to the use of combined imaging modalities. Positron emission tomography (PET) and computed tomography (CT) is a hybrid imaging existing already for many years. The high spatial and contrast resolution of magnetic resonance imaging (MRI) and the high sensitivity and molecular information from PET imaging are leading to the development of this new hybrid imaging along with hybrid contrast agents. To create a hybrid contrast agent for PET-MRI device, a PET radiotracer needs to be combined with an MRI contrast agent. The most common approach is to add a radioactive isotope to the surface of a small superparamagnetic iron oxide (SPIO) particle. The resulting agents offer a wide range of applications, such as pH variation monitoring, non-invasive angiography and early imaging diagnosis of atherosclerosis. Oncology is the most promising field with the detection of sentinel lymph nodes and the targeting of tumor neoangiogenesis. Oncology and cardiovascular imaging are thus major areas of development for hybrid PET-MRI imaging systems and hybrid contrast agents. The aim is to combine high spatial resolution, high sensitivity, morphological and functional information. Future prospects include the use of specific antibodies and hybrid multimodal PET-MRI-ultrasound-fluorescence imaging with the potential to provide overall pre-, intra- and postoperative patient care.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.