† Transoesophageal Doppler (TED) is useful to guide intraoperative volume expansion (VE) in neonates and young infants. † TED derived stroke volume accurately predicts responsiveness to VE. † VE based on standard monitoring data is inappropriate in more than 50% of patients. † TED monitoring can avoid undue fluid loading. Background. Volume expansion (VE) in neonates or infants during volatile anaesthesia may lead to fluid overload if inappropriate. Transoesophageal Doppler (TED), a non-invasive cardiac output monitoring technique, can provide a comprehensive estimation of the volaemic status. We evaluated whether intraoperative TED-derived parameters can predict volume responsiveness. Methods. Neonates and infants under general anaesthesia without myocardial dysfunction were prospectively included when the attending anaesthetist, blinded to TED measurements, decided to provide VE based on clinical appreciation and standard monitoring data. Standard and TED-derived data were recorded before and after VE. After VE, patients were classified as responders and non-responders, if their indexed stroke volume (iSV) increased by more than 15% or not, respectively. The attending anaesthetist assessment of VE responsiveness was recorded at the end of VE. Results. Fifty patients aged 42 (4) post-conceptional weeks were included, among which 26 (52%) were responders. Baseline iSV was the only parameter associated with VE responsiveness. Baseline iSV was fairly correlated with VE-induced changes in iSV (r¼20.64) and was associated with an area under the receiver operating characteristic curve of 0.90 (0.80, 0.99). Using a cutoff of 25 ml m 22 , baseline iSV predicted volume responsiveness with a sensitivity of 92% and a specificity of 83%. Attending anaesthetists' assessment of VE effectiveness agreed only moderately with TED measurements of iSV changes. Conclusions. TED-derived iSV measurement during volatile anaesthesia is useful to predict and follow VE responsiveness in neonates and infants without myocardial dysfunction.
TED-derived iSV measurement during volatile anaesthesia is useful to predict and follow VE responsiveness in neonates and infants without myocardial dysfunction.
BACKGROUND:
Whole blood (WB) is becoming the preferred product for the resuscitation of hemorrhaging trauma patients. However, there is a lack of data on the optimum timing of receiving WB. We aimed to assess the effect of time to WB transfusion on the outcomes of trauma patients.
STUDY DESIGN:
The American College of Surgeons TQIP 2017 to 2019 database was analyzed. Adult trauma patients who received at least 1 unit of WB within the first 2 hours of admission were included. Patients were stratified by time to first unit of WB transfusion (first 30 minutes, second 30 minutes, and second hour). Primary outcomes were 24-hour and in-hospital mortality, adjusting for potential confounders.
RESULTS:
A total of 1,952 patients were identified. Mean age and systolic blood pressure were 42 ± 18 years and 101 ± 35 mmHg, respectively. Median Injury Severity Score was 17 [10 to 26], and all groups had comparable injury severities (p = 0.27). Overall, 24-hour and in-hospital mortality rates were 14% and 19%, respectively. Transfusion of WB after 30 minutes was progressively associated with increased adjusted odds of 24-hour mortality (second 30 minutes: adjusted odds ratio [aOR] 2.07, p = 0.015; second hour: aOR 2.39, p = 0.010) and in-hospital mortality (second 30 minutes: aOR 1.79, p = 0.025; second hour: aOR 1.98, p = 0.018). On subanalysis of patients with an admission shock index >1, every 30-minute delay in WB transfusion was associated with higher odds of 24-hour (aOR 1.23, p = 0.019) and in-hospital (aOR 1.18, p = 0.033) mortality.
CONCLUSIONS:
Every minute delay in WB transfusion is associated with a 2% increase in odds of 24-hour and in-hospital mortality among hemorrhaging trauma patients. WB should be readily available and easily accessible in the trauma bay for the early resuscitation of hemorrhaging patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.