• Clinical examination is important for diagnosis of carpal tunnel syndrome • Shear wave elastography (SWE) offers new clinical opportunities within diagnostic ultrasound • SWE is highly reproducible in evaluation of median nerve stiffness • Median nerve stiffness is significantly increased in carpal tunnel syndrome • Elastography could become useful in diagnosis of carpal tunnel syndrome.
Purpose To evaluate the value of shear-wave elastography (SWE) in the detection of diabetic peripheral neuropathy (DPN) of the tibial nerve. Materials and Methods This study was approved by the institutional review board, and written informed consent was obtained from all study participants. The study included 20 diabetic patients with DPN (10 men, 10 women), 20 diabetic patients without DPN (eight men, 12 women), and 20 healthy control subjects (nine men, 11 women). The tibial nerve was examined at 4 cm proximal to the medial malleolus with gray-scale ultrasonography and SWE. The nerve cross-sectional area (in square centimeters) and the mean nerve stiffness (in kilopascals) within the range of the image were recorded. Inter- and intrareader variability, differences among groups, and correlation of clinical and electrophysiologic evaluation were assessed with intraclass correlation coefficients, the Mann Whitney U test, and the Wilcoxon signed rank test. Results Between diabetic patients with and diabetic patients without DPN, mean age (60 years [range, 38-79 years] vs 61 years [range, 46-75 years], respectively), mean duration of diabetes (10 years [range, 1-25 years] vs 10 years [range, 2-26 years]), and mean body mass index (31.4 kg/m [range, 24.7-48.1 kg/m] vs 29.8 kg/m [range, 22.9-44.0 kg/m]) were not significantly different. Diabetic patients without DPN had significantly higher stiffness values on the right side compared with control subjects (P < .001). Patients with DPN had much higher stiffness values on both sides compared with both diabetic patients without DPN (P < .001) and healthy control subjects (P < .001). A cutoff value of 51.0 kPa at 4 cm proximal to the medial malleolus revealed a sensitivity of 90% (95% confidence interval [CI]: 75.4%, 96.7%) and a specificity of 85.0% (95% CI: 74.9%, 91.7%). Conclusion Tibial nerve stiffness measurements appear to be highly specific in the diagnosis of established DPN. The increased stiffness in subjects without DPN might indicate that the nerve is affected by diabetes. RSNA, 2016 Online supplemental material is available for this article.
ORIGINAL ARTICLE PURPOSE We aimed to determine the correlations between the elasticity values of solid breast masses and histopathological findings to define cutoff elasticity values differentiating malignant from benign lesions. MATERIALS and METHODSA total of 115 solid breast lesions of 109 consecutive patients were evaluated prospectively using shear wave elastography (SWE). Two orthogonal elastographic images of each lesion were obtained. Minimum, mean, and maximum elasticity values were calculated in regions of interest placed over the stiffest areas on the two images; we also calculated mass/fat elasticity ratios. Correlation of elastographic measurements with histopathological results were studied. RESULTS Eighty-three benign and thirty-two malignant lesions were histopathologically diagnosed. The minimum, mean, and maximum elasticity values, and the mass/fat elasticity ratios of malignant lesions, were significantly higher than those of benign lesions. The cutoff value was 45.7 kPa for mean elasticity (sensitivity, 96%; specificity, 95%), 54.3 kPa for maximum elasticity (sensitivity, 95%; specificity, 94%), 37.1 kPa for minimum elasticity (sensitivity, 96%; specificity, 95%), and 4.6 for the mass/fat elasticity ratio (sensitivity, 97%; specificity, 95%). CONCLUSION SWE yields additional valuable quantitative data to ultrasonographic examination on solid breast lesions. SWE may serve as a complementary tool for diagnosis of breast lesions. Long-term clinical studies are required to accurately select lesions requiring biopsy.
Shear wave elastography can be used with grayscale sonography for evaluation of cases to decide on needle biopsy sampling. However, it cannot be used as a replacement for fine-needle aspiration or SLN dissection.
Vascular involvement can be seen in up to 40% of patients with Behcet syndrome (BS), the lower-extremity vein thrombosis (LEVT) being the most common type. The aim of the current study was to compare venous Doppler findings and clinical features between BS patients with LEVT and control patients diagnosed as having LEVT due to other causes.All consecutive 78 patients (71 men, 7 women; mean age 38.6 ± 10.3 years) with LEVT due to BS and 50 control patients (29 men, 21 women; mean age 42.0 ± 12.5 years) who had LEVT due to other causes, or idiopathic, were studied with the help of a Doppler ultrasonography after a detailed clinical examination. Patterns of venous disease were identified by cluster analyses. Clinical features of chronic venous disease were assessed using 2 classification systems. Venous claudication was also assessed.Patients with BS were more likely to be men, had significantly earlier age of onset of thrombosis, and were treated mainly with immunosuppressives and less frequently with anticoagulants. Furthermore, they had significantly more bilateral involvement, less complete recanalization, and more frequent collateral formation. While control patients had a disorganized pattern of venous involvement, BS patients had a contiguous and symmetric pattern, involving all deep and superficial veins of the lower extremities, with less affinity for crural veins. Clinical assessment, as measured by the 2 classification systems, also indicated a more severe disease among the BS patients. In line, 51% of the BS patients suffered from severe post-thrombotic syndrome (PTS) and 32% from venous claudication, whereas these were present in 8% and 12%, respectively, among the controls. Among BS patients, a longer duration of thrombosis, bilateral femoral vein involvement, and using no anticoagulation along with immunosuppressive treatment when first diagnosed were found to be associated independently with severe PTS.Lower-extremity vein thrombosis associated with BS, when compared to LEVT due to other causes, had distinctive demographic and ultrasonographic characteristics, and had clinically a more severe disease course.
BackgroundPrimary open-angle glaucoma is a multifactorial serious disease characterized by progressive retinal ganglion cell death and loss of visual field.ObjectivesThe purposes of this study were to investigate shear wave elastography (SWE) use in the evaluation of the optic nerve (ON) and peripapillary structures, and to compare the findings between glaucomatous and control eyes.Patients and MethodsA case-controlled study, including 21 patients with primary open-angle glaucoma and 21 age-matched control subjects, was carried out. All of the participants had comprehensive ophthalmological exams that included corneal biomechanical measurements with ocular response analyzer. In vivo evaluation of the biomechanical properties of the ON and peripapillary structures were performed with SWE in all participants. The Kolmogorov–Smirnov test was used to analyze the normal distribution of data. Differences of parameters in ophthalmologic data and stiffness values of patients with and without glaucoma were evaluated using the Mann-Whitney U test.ResultsThere were no statistically significant differences between the glaucoma and control groups in terms of age (P > 0.05) and gender (P > 0.05). Corneal hysteresis was lower in the glaucoma group (P < 0.05). Corneal compensated intraocular pressure and Goldmann correlated intraocular pressure were higher in the glaucoma group (P < 0.0001 for both). The mean stiffness of the ON and peripapillary structures were significantly higher in glaucoma patients for each measured region (P < 0.05).ConclusionThe study evaluated the biomechanical properties of the ON and peripapillary structures in vivo with SWE in glaucoma. We observed stiffer ON and peripapillary tissue in glaucomatous eyes, indicating that SWE claims new perspectives in the evaluation of ON and peripapillary structures in glaucoma disease.
Rheumatoid meningitis is a rare and serious complication of rheumatoid arthritis (RA) with high mortality rate. Clinical importance of the disease is high because diagnosis is difficult, and the disease is treatable if diagnosed successfully. We present the clinical and cranial magnetic resonance imaging findings of 62-year-old female patient with RA who has been followed up for 4 years.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.