We present a nonlocal weighted sparse representation (NWSR) method for reconstruction of retinal optical coherence tomography (OCT) images. To reconstruct a high signal-to-noise ratio and high-resolution OCT images, utilization of efficient denoising and interpolation algorithms are necessary, especially when the original data were subsampled during acquisition. However, the OCT images suffer from the presence of a high level of noise, which makes the estimation of sparse representations a difficult task. Thus, the proposed NWSR method merges sparse representations of multiple similar noisy and denoised patches to better estimate a sparse representation for each patch. First, the sparse representation of each patch is independently computed over an overcomplete dictionary, and then a nonlocal weighted sparse coefficient is computed by averaging representations of similar patches. Since the sparsity can reveal relevant information from noisy patches, combining noisy and denoised patches' representations is beneficial to obtain a more robust estimate of the unknown sparse representation. The denoised patches are obtained by applying an off-the-shelf image denoising method and our method provides an efficient way to exploit information from noisy and denoised patches' representations. The experimental results on denoising and interpolation of spectral domain OCT images demonstrated the effectiveness of the proposed NWSR method over existing state-of-the-art methods.
In recent years, there has been a growing interest in applying convolutional neural networks (CNNs) to low-level vision tasks such as denoising and super-resolution. Due to the coherent nature of the image formation process, optical coherence tomography (OCT) images are inevitably affected by noise. This paper proposes a new method named the multi-input fully-convolutional networks (MIFCN) for denoising of OCT images. In contrast to recently proposed natural image denoising CNNs, the proposed architecture allows the exploitation of high degrees of correlation and complementary information among neighboring OCT images through pixel by pixel fusion of multiple FCNs. The parameters of the proposed multi-input architecture are learned by considering the consistency between the overall output and the contribution of each input image. The proposed MIFCN method is compared with the state-of-the-art denoising methods adopted on OCT images of normal and age-related macular degeneration eyes in a quantitative and qualitative manner.Index Terms-Fully convolutional network (FCN), Multi-input FCN, Image denoising, Optical Coherence Tomography (OCT).
Purpose The presence of imbalanced datasets in medical applications can negatively affect deep learning methods. This study aims to investigate how the performance of convolutional neural networks (CNNs) for glaucoma diagnosis can be improved by addressing imbalanced learning issues through utilizing glaucoma suspect samples, which are often excluded from studies because they are a mixture of healthy and preperimetric glaucomatous eyes, in a semi-supervised learning approach. Methods A baseline 3D CNN was developed and trained on a real-world glaucoma dataset, which is naturally imbalanced (like many other real-world medical datasets). Then, three methods, including reweighting samples, data resampling to form balanced batches, and semi-supervised learning on glaucoma suspect data were applied to practically assess their impacts on the performances of the trained methods. Results The proposed method achieved a mean accuracy of 95.24%, an F1 score of 97.42%, and an area under the curve of receiver operating characteristic (AUC ROC) of 95.64%, whereas the corresponding results for the traditional supervised training using weighted cross-entropy loss were 92.88%, 96.12%, and 92.72%, respectively. The obtained results show statistically significant improvements in all metrics. Conclusions Exploiting glaucoma suspect eyes in a semi-supervised learning method coupled with resampling can improve glaucoma diagnosis performance by mitigating imbalanced learning issues. Translational Relevance Clinical imbalanced datasets may negatively affect medical applications of deep learning. Utilizing data with uncertain diagnosis, such as glaucoma suspects, through a combination of semi-supervised learning and class-imbalanced learning strategies can partially address the problems of having limited data and learning on imbalanced datasets.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.