Background Anti-TNF drugs are effective treatments for the management of Crohn's disease but treatment failure is common. We aimed to identify clinical and pharmacokinetic factors that predict primary non-response at week 14 after starting treatment, non-remission at week 54, and adverse events leading to drug withdrawal.Methods The personalised anti-TNF therapy in Crohn's disease study (PANTS) is a prospective observational UK-wide study. We enrolled anti-TNF-naive patients (aged ≥6 years) with active luminal Crohn's disease at the time of first exposure to infliximab or adalimumab between March 7, 2013, and July 15, 2016. Patients were evaluated for 12 months or until drug withdrawal. Demographic data, smoking status, age at diagnosis, disease duration, location, and behaviour, previous medical and drug history, and previous Crohn's disease-related surgeries were recorded at baseline. At every visit, disease activity score, weight, therapy, and adverse events were recorded; drug and total anti-drug antibody concentrations were also measured. Treatment failure endpoints were primary non-response at week 14 ,non-remission at week 54, and adverse events leading to drug withdrawal. We used regression analyses to identify which factors were associated with treatment failure. Findings We enrolled 955 patients treated with infliximab (753 with originator; 202 with biosimilar) and 655 treated with adalimumab. Primary non-response occurred in 295 (23•8%, 95% CI 21•4-26•2) of 1241 patients who were assessable at week 14. Non-remission at week 54 occurred in 764 (63•1%, 60•3-65•8) of 1211 patients who were assessable, and adverse events curtailed treatment in 126 (7•8%, 6•6-9•2) of 1610 patients. In multivariable analysis, the only factor independently associated with primary non-response was low drug concentration at week 14 (infliximab: odds ratio 0•35 [95% CI 0•20-0•62], p=0•00038; adalimumab: 0•13 [0•06-0•28], p<0•0001); the optimal week 14 drug concentrations associated with remission at both week 14 and week 54 were 7 mg/L for infliximab and 12 mg/L for adalimumab. Continuing standard dosing regimens after primary non-response was rarely helpful; only 14 (12•4% [95% CI 6•9-19•9]) of 113 patients entered remission by week 54. Similarly, week 14 drug concentration was also independently associated with non-remission at week 54 (0•29 [0•16-0•52] for infliximab; 0•03 [0•01-0•12] for adalimumab; p<0•0001 for both). The proportion of patients who developed anti-drug antibodies (immunogenicity) was 62•8% (95% CI 59•0-66•3) for infliximab and 28•5% (24•0-32•7) for adalimumab. For both drugs, suboptimal week 14 drug concentrations predicted immunogenicity, and the development of anti-drug antibodies predicted subsequent low drug concentrations. Combination immuno-modulator (thiopurine or methotrexate) therapy mitigated the risk of developing anti-drug antibodies (hazard ratio 0•39 [95% CI 0•32-0•46] for infliximab; 0•44 [0•31-0•64] for adalimumab; p<0•0001 for both). For infliximab, multivariable analysis of immunododulator ...
This population-based cohort shows marked changes in rates of surgery, and the reduction is independently associated with year of diagnosis, and associated temporally with increased and earlier thiopurine use.
BACKGROUND & AIMS: Anti-tumor necrosis factor (anti-TNF) therapies are the most widely used biologic drugs for treating immune-mediated diseases, but repeated administration can induce the formation of anti-drug antibodies. The ability to identify patients at increased risk for development of anti-drug antibodies would facilitate selection of therapy and use of preventative strategies. METHODS: We performed a genomewide association study to identify variants associated with time to development of anti-drug antibodies in a discovery cohort of 1240 biologic-naïve patients with Crohn's disease starting infliximab or adalimumab therapy. Immunogenicity was defined as an anti-drug antibody titer !10 AU/mL using a drug-tolerant enzyme-linked immunosorbent assay. Significant association signals were confirmed in a replication cohort of 178 patients with inflammatory bowel disease. RESULTS: The HLA-DQA1*05 allele, carried by approximately 40% of Europeans, significantly increased the rate of immunogenicity (hazard ratio [HR], 1.90; 95% confidence interval [CI], 1.60-2.25; P ¼ 5.88 Â 10-13). The highest rates of immunogenicity, 92% at 1 year, were observed in patients treated with infliximab monotherapy who carried HLA-DQA1*05; conversely the lowest rates of immunogenicity, 10% at 1 year, were observed in patients treated with adalimumab combination therapy who did not carry HLA-DQA1*05. We confirmed this finding in the replication cohort (HR, 2.00; 95% CI, 1.35-2.98; P ¼ 6.60 Â 10-4). This association was consistent for patients treated with adalimumab (HR, 1.89; 95% CI, 1.32-2.70) or infliximab (HR, 1.92; 95% CI, 1.57-2.33), and for patients treated with anti-TNF therapy alone
ObjectiveLow adenoma detection rates (ADR) are linked to increased postcolonoscopy colorectal cancer rates and reduced cancer survival. Devices to enhance mucosal visualisation such as Endocuff Vision (EV) may improve ADR. This multicentre randomised controlled trial compared ADR between EV-assisted colonoscopy (EAC) and standard colonoscopy (SC).DesignPatients referred because of symptoms, surveillance or following a positive faecal occult blood test (FOBt) as part of the Bowel Cancer Screening Programme were recruited from seven hospitals. ADR, mean adenomas per procedure, size and location of adenomas, sessile serrated polyps, EV removal rate, caecal intubation rate, procedural time, patient experience, effect of EV on workload and adverse events were measured.Results1772 patients (57% male, mean age 62 years) were recruited over 16 months with 45% recruited through screening. EAC increased ADR globally from 36.2% to 40.9% (P=0.02). The increase was driven by a 10.8% increase in FOBt-positive screening patients (50.9% SC vs 61.7% EAC, P<0.001). EV patients had higher detection of mean adenomas per procedure, sessile serrated polyps, left-sided, diminutive, small adenomas and cancers (cancer 4.1% vs 2.3%, P=0.02). EV removal rate was 4.1%. Median intubation was a minute quicker with EAC (P=0.001), with no difference in caecal intubation rate or withdrawal time. EAC was well tolerated but caused a minor increase in discomfort on anal intubation in patients undergoing colonoscopy with no or minimal sedation. There were no significant EV adverse events.ConclusionEV significantly improved ADR in bowel cancer screening patients and should be used to improve colonoscopic detection.Trial registration numberNCT02552017, Results; ISRCTN11821044, Results.
BackgroundAccurate optical characterisation and removal of small adenomas (<10 mm) at colonoscopy would allow hyperplastic polyps to be left in situ and surveillance intervals to be determined without the need for histopathology. Although accurate in specialist practice the performance of narrow band imaging (NBI), colonoscopy in routine clinical practice is poorly understood.MethodsNBI-assisted optical diagnosis was compared with reference standard histopathological findings in a prospective, blinded study, which recruited adults undergoing routine colonoscopy in six general hospitals in the UK. Participating colonoscopists (N=28) were trained using the NBI International Colorectal Endoscopic (NICE) classification (relating to colour, vessel structure and surface pattern). By comparing the optical and histological findings in patients with only small polyps, test sensitivity was determined at the patient level using two thresholds: presence of adenoma and need for surveillance. Accuracy of identifying adenomatous polyps <10 mm was compared at the polyp level using hierarchical models, allowing determinants of accuracy to be explored.FindingsOf 1688 patients recruited, 722 (42.8%) had polyps <10 mm with 567 (78.5%) having only polyps <10 mm. Test sensitivity (presence of adenoma, N=499 patients) by NBI optical diagnosis was 83.4% (95% CI 79.6% to 86.9%), significantly less than the 95% sensitivity (p<0.001) this study was powered to detect. Test sensitivity (need for surveillance) was 73.0% (95% CI 66.5% to 79.9%). Analysed at the polyp level, test sensitivity (presence of adenoma, N=1620 polyps) was 76.1% (95% CI 72.8% to 79.1%). In fully adjusted analyses, test sensitivity was 99.4% (95% CI 98.2% to 99.8%) if two or more NICE adenoma characteristics were identified. Neither colonoscopist expertise, confidence in diagnosis nor use of high definition colonoscopy independently improved test accuracy.InterpretationThis large multicentre study demonstrates that NBI optical diagnosis cannot currently be recommended for application in routine clinical practice. Further work is required to evaluate whether variation in test accuracy is related to polyp characteristics or colonoscopist training.Trial registration numberThe study was registered with clinicaltrials.gov (NCT01603927).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.