The performance, energy storage capacity, safety, and lifetime of lithium-ion battery cells of different chemistries are very sensitive to operating and environmental temperatures. The cells generate heat by current passing through their internal resistances, and chemical reactions can generate additional, sometimes uncontrollable, heat if the temperature within the cells reaches the trigger temperature. Therefore, a high-performance battery cooling system that maintains cells as close to the ideal temperature as possible is needed to enable the highest possible discharge current rates while still providing a sufficient safety margin. This paper presents a novel design, preliminary development, and results for an inexpensive reusable, liquid-cooled, modular, hexagonal battery module that may be suitable for some mobile and stationary applications that have high charge and or discharge rate requirements. The battery temperature rise was measured experimentally for a six parallel 18650 cylindrical cell demonstrator module over complete discharge cycles at discharge rates of 1C, 2C and 3C. The measured temperature rises at the hottest point in the cells, at the anode terminal, were found to be 6, 17 and 22 °C, respectively. The thermal resistance of the system was estimated to be below 0.2 K/W at a coolant flow rate of 0.001 Kg/s. The proposed liquid cooled module appeared to be an effective solution for maintaining cylindrical Li-ion cells close to their optimum working temperature.
<div class="section abstract"><div class="htmlview paragraph">Micro-mobility vehicles such as electric scooters and bikes are increasingly used for urban transportation; their designs usually trade off performance and range. Addressing thermal and cooling issues in such vehicles could enhance performance, reliability, life, and range. Limited packaging space within the wheels precludes the use of complex cooling systems that would also increase the cost and complexity of these mass-produced wheel motors. The present study begins by evaluating the external aerodynamics of the scooter to characterise the airflow conditions near the rotating wheel; then, a steady-state conjugate heat transfer model of a commercially available wheel hub motor (500W) is created using commercial computational fluid dynamics (CFD) software, StarCCM+. The CAD model of the motor used for this analysis has an external rotor permanent magnet (PM) brushless DC topology. Both internal and external fluid domains are considered to evaluate the combined flow dynamics and conjugate heat transfer from the windings (heat source) to the ambient air. At the maximum speed (482rpm) of the motor, for a total power loss of 180W (η=64%), a maximum temperature of 295°C is observed in the windings. Evaluating the thermal path shows that approximately 58.1% of the total heat generated in the winding is dissipated radially via convection through the air gap, and only 3.66% through the shaft via conduction. The thermal resistance for the shaft is in the range of 22-60 K/W and the rotor components is in the range of 0-2 K/W for the operational speed range of 0-1000rpm. Taguchi’s Design of Experiment (DOE) with Design manager study has been conducted to optimize the performance of design parameters (Fins and air-vents/<i>holes</i>) in cooling the motor. Air vents and external fins on rotor–lid (rotor <i>cover</i>) has a greater effect on cooling the motor than other design parameters.</div></div>
The geometry of commercially available wheel hub motors inherently restricts packaging space and may prevent the introduction of more sophisticated, efficient, and expensive cooling systems. Due to the limited available space in the wheels, commercial hub motors often rely on aerodynamic passive cooling. The small air-gap (0.5–1 mm) between the coils and the magnets results in heat transfer to the magnets and consequently increases their temperature. As a result, the perfeormance of the permanent magnets (PMs) will be limited and also will heavily affect their lifetime; thus, advanced cooling strategies must be introduced. In the current study, a three-dimensional (3D) thermal model was developed for a commercially available 500 W scooter hub motor under a constant heat load of 180 W using Computational Fluid Dynamics (CFD) (= 64%).The spatial distribution of the temperature for the motor parts are evaluated considering both the internal and external fluid flow dynamics. Further, analysis of airflow in the the gap is performed and the results from the CFD is compared with the published correlations. The flow in such small motor was found to be laminar with Taylor number below 40. Results also showed that enhancement of the cooling is necessary to avoid damage of the winding vernish and to reduce the magnets temperature particularly when the motor works at high torque with low efficiency.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.