Background:
Transcatheter ventricular septal defect closure remains a complex procedure with potential complications like complete heart block and aortic regurgitation. The ideal device design for such intervention is still evolving.
Aim:
To assess the safety, efficacy, and short-term outcome of ventricular septal defect closure using LifeTechTM multifunctional (KONAR-MFTM) VSD Occluder.
Patients and methods:
In a multicenre study, 44 patients with haemodynamically significant, restrictive ventricular septal defects underwent closure with the KONAR-MFTM device from April, 2019 to March, 2020. Clinical, echocardiographic, and angiographic data were collected and reviewed. Patients were followed up at 1, 3, 6, and 12 months.
Results:
The median age and weight were 8 (1.7–36) years and 20 (11–79) kg. Of 44 patients, 8 (18%) had a high muscular and 36 (82%) had a perimembranous defect, of which 6 had mild prolapse of the right coronary cusp. The median ventricular septal defect size was 8.8 (3.9–13.4) mm. A retrograde approach was adopted in 39 (88.6%) patients. Nine patients (20.5%) had a small residual leak and there was a slight increase in aortic regurgitation in one patient. One device, which embolised to pulmonary artery was retrieved, and the defect was closed with a larger device. At a median follow-up of 13 (5–18) months, the residual leak persisted in 1 (2.3%) patient. Mild aortic regurgitation in one patient remained unchanged. There were no major complications.
Conclusion:
Percutaneous closure of ventricular septal defect using KONAR-MFTM device is safe and effective in short and midterm follow-up including selected patients with perimembranous defect and mild prolapse of the right coronary cusp.
IntroductionCardiac catheterization is widely considered the “gold standard” for the diagnosis of pulmonary hypertension. However, its routine use is limited due to its invasive nature. Therefore, the aim of this study was to evaluate the correlation between pulmonary artery pressures obtained by various parameters of transthoracic echocardiography and cardiac catheterization.MethodsThis study includes 50 consecutive patients with intracardiac shunt lesions diagnosed with severe pulmonary hypertension on echocardiography and admitted for cardiac catheterization at the National Institute of Cardiovascular Diseases (NICVD) in Karachi, Pakistan. Cardiac catheterization and transthoracic echocardiography were performed in all patients simultaneously and systolic (sPAP) and mean pulmonary artery pressure (mPAP) were assessed with both modalities. Correlations and agreement, in terms of Bland-Altman plot, were computed between both modalities for sPAP and mPAP.ResultsOut of 50 patients, 46% (23) were male and mean age was 7.49 ± 4.45 years. On cardiac catheterization, sPAP was 93.92 ± 17.91 mmHg and mPAP was 67.0 ± 14.28 mmHg. Correlation between cardiac catheterization and echocardiography for the assessment of sPAP was 0.917 (p<0.001), and mPAP was 0.832 (p<0.001) for mean gradient of tricuspid regurgitation (PGTRmean), 0.749 (p<0.001) for peak gradient of pulmonary regurgitation (PGPRpeak), 0.691 (p<0.001) for Acceleration time across right ventricular outflow tract (RVOT), and 0.752 (p<0.001) for end gradient of pulmonary regurgitation (PGPRend). Bland-Altman plot showed moderate agreement between two modalities.ConclusionA positive but modest correlation was observed between hemodynamic parameters of transthoracic echocardiography and cardiac catheterization for assessment of pulmonary artery pressures. Transthoracic echocardiography can reliably be used as an initial non-invasive modality for the assessment of pulmonary artery hypertension and can obviate the need of right heart catheterization in some patient especially with mild pulmonary hypertension.
Background Transthoracic echocardiography (TTE) plays a vital role in the assessment of the surgical management of patients with tetralogy of Fallot (TOF). Accurate assessment of the main pulmonary valve annulus, main pulmonary artery (MPA), and branch pulmonary arteries are crucial for decision-making regarding the surgical approach in the form of total correction. It is also important for performing a systemic-to-pulmonary artery shunt operation and affects the outcome. In some patients with poor echogenic windows, it is sometimes difficult to obtain accurate measurements. Cardiac computed tomographic angiography (CTA) can be a superior diagnostic modality. Therefore, the aim of this study was to evaluate the degree of agreement between TTE and CTA in assessing the main pulmonary valve annulus and the size of the MPA and its branches among patients with TOF patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.