This work demonstrates that a full laboratory-quality immunoassay can be run on a smartphone accessory. This low-cost dongle replicates all mechanical, optical, and electronic functions of a laboratory-based enzyme-linked immunosorbent assay (ELISA) without requiring any stored energy; all necessary power is drawn from a smartphone. Rwandan health care workers used the dongle to test whole blood obtained via fingerprick from 96 patients enrolling into care at prevention of mother-to-child transmission clinics or voluntary counseling and testing centers. The dongle performed a triplexed immunoassay not currently available in a single test format: HIV antibody, treponemal-specific antibody for syphilis, and nontreponemal antibody for active syphilis infection. In a blinded experiment, health care workers obtained diagnostic results in 15 min from our triplex test that rivaled the gold standard of laboratory-based HIV ELISA and rapid plasma reagin (a screening test for syphilis), with sensitivity of 92 to 100% and specificity of 79 to 100%, consistent with needs of current clinical algorithms. Patient preference for the dongle was 97% compared to laboratory-based tests, with most pointing to the convenience of obtaining quick results with a single fingerprick. This work suggests that coupling microfluidics with recent advances in consumer electronics can make certain laboratory-based diagnostics accessible to almost any population with access to smartphones.
We describe a point-of-care immunochromatographic test for the simultaneous detection of both nontreponemal and treponemal antibodies in the sera of patients with syphilis that acts as both a screening and a confirmatory test. A total of 1,601 banked serum samples were examined by the dual test, and the results were compared to those obtained using a quantitative rapid plasma reagin (RPR) test and the Treponema pallidum passive particle agglutination (TP-PA) assay. Compared to the RPR test, the reactive concordance of the dual test nontreponemal line was 98.4% when the RPR titers of sera were >1:2 and the nonreactive concordance was 98.6%. Compared to the TP-PA assay, the reactive and nonreactive concordances of the treponemal line were 96.5% and 95.5%, respectively. These results indicate that the dual test could be used for the serological diagnosis of syphilis in primary health care clinics or resource-poor settings and therefore improve rates of treatment where patients may fail to return for their laboratory results.
A combined treponemal and nontreponemal rapid diagnostic test was found to have good sensitivity and specificity for both syphilis and yaws. The performance of both the treponemal and nontreponemal test components was strongly associated with the rapid plasma reagin titer.
ObjectiveThe serological diagnosis of syphilis requires the detection of two distinct antibodies, the non-treponemal and trepomenal. Center for Disease Control and Prevention (CDC) recommends screening first with a non-treponemal test such as (Rapid Plasma Reagin/Venereal Disease Research Laboratory), and then confirming those results with one of the several treponemal tests (Fluorescent Treponemal Antibody-Absorption (FTA-ABS), Enzyme Immunoassay, chemiluminescence, treponema pallidum particle agglutination (TP-PA) or Point of Care). Owing to the high volume of samples processed by some laboratories using automated systems, the screening with treponemal assays and confirming with non-treponemal tests is becoming the established norm. The purpose of this study was to evaluate eight treponemal assays using TP-PA as the predicate assay.Methods290 stored serum samples were tested qualitatively according to the manufacturer's directions.ResultsConcordance with specimens tested as reactive or non-reactive using TP-PA was: FTA-ABS 94.5–100%, Trep-Sure 100–98.9%, BioELISA 100–98.9%, INNO-LIA 99.1–99.4%, BIOLINE 100–98.9%, CAPTIA IgG 100–97.2%, Trep-ID 100–100% and LIAISON 100–99.4%. In order to properly evaluate the performance of these assays, the analytical sensitivity was determined by endpoint titration of serial dilutions of the reactive serum samples in normal sera. The median endpoint titre varied from 1:4 for FTA-ABS to 1:512 for Trep-Sure.ConclusionsThe performance of the treponemal serological assays was comparable while using medium and high-titre sera. However, the varying performance on specimen dilutions suggests that there may be differences in sensitivity with low-titre sera that are more prevalent in primary and late syphilis cases.
Backscattering interferometry enables the detection of syphilis antibody–antigen interactions in the presence of human serum, showing promise as a diagnostic tool for the serological diagnosis of infectious disease with potentially quantitative capabilities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.