Bilateral pectoralis major flap repair is a safe technique to cure severe mediastinitis necessitating complete sternal resection. Wounds close without extensive reconstructive surgery. Cosmetic results as well as stabilization of the chest were good. Patients reported an almost uncompromised quality of life without respiratory impairment.
The majority of patients with a history of AF show not only disorganized but also highly organized AT episodes, which can be successfully terminated by ATP.
Coronary blood flow was significantly influenced by mechanical aortic valve implantation and the orientation of prostheses. For both valve designs, the previously defined optimum orientation with respect to pressure gradients and turbulence demonstrated the highest left anterior descending flow rates. Even in its optimum orientation, the St Jude Medical valve showed significantly lower coronary flow than the other valves.
SCHERER, M., et al.: Extension of Generator Longevity by Use of High Impedance Ventricular Leads. The resistance of a pacing lead negatively correlates to current consumption. A prospective, randomized trial was conducted to evaluate the effect of a high impedance ventricular lead (CapSure Z) on generator longevity compared to a conventional lead (CapSure SP) eighty‐nine patients were included in the study (51 male, 37 female, age 70.0 ± 10.3 years). Forty‐six patients received a CapSure SP lead (5024 bipolar), and 43 patients received a CapSure Z lead (5034 bipolar) in a randomized fashion. Follow‐up data collected at 5 days, 3, 6, and 12 months postimplant included: lead impedance, pacing and sensing thresholds, impulse energy, and estimated time to replacement. All parameters were collected via pacemaker telemetry; the time to replacement was calculated automatically by a programmed algorithm of the pacemaker. There was no difference in the performance of the atrial lead when a dual chamber device was indicated. The CapSure Z leads displayed statistically significant higher impedance values than the CapSure SP lead in all follow‐up periods. There was no significant difference in lead related complications. No significant differences were observed between pacing and sensing thresholds in both groups. The CapSure Z leads provided a significant reduction in current drain, resulting in a reduction of mean energy consumption at the 12‐month follow‐up from 10.4 ± 5.0 μJ in the CapSure SP group to 6.6 ± 1.4 μJ in the CapSure Z group (median from 9.9 μJ to 6.9 μJ, respectively), providing an estimated increase in mean longevity of more than 1 year from 81.1 ± 23.5 months in the CapSure SP group to 94.5 ± 13.4 months in the CapSure Z group (median: 76.5 months to 95.0 months, respectively). The use of a high resistance lead for ventricular pacing appears to result in a clinically relevant extension of generator longevity.
Objective External stents placed around vein grafts have demonstrated effectiveness in reducing neointimal hyperplasia by preventing distension of the thin-walled vein grafts when exposed to arterial pressure. However, the ideal stent material has yet to be defined. The following study investigates the short- and long-term effects of an innovative polyester mesh stent designed with optimized adaptation of circumferential compliance. Methods Following in vitro definition of the ideal macro-porous polyester stent material, a total of 12 sheep underwent implantation of bilateral carotid artery vein graft bypasses. In six sheep, the short-term outcome (four weeks of implantation) was investigated by comparing the newly-designed stent to native veins, micro-porous PTFE stent grafts and metallic Biocompound® stents (BCGs). Flow volume and graft diameter were measured prior to explantation. Grafts were evaluated histologically with respect to morphometry and immunoassaying. In the long-term group (6-month implantation time), the polyester stent was compared to native veins. Results All stents effectively prevented dilatation of the graft. Perfused vessel diameters of the polyester veins were 8.3±0.6 mm. BCG as well as PTFE veins showed diameter reduction to 7.4±0.7mm (p<0.05) and 7.8±0.4 mm (p<0.05), respectively. Both in the short and long terms, the new polyester stent led to significantly higher reduction of neointimal hyperplasia and luminal encroachment compared to the native vessel. It proved superior to PTFE stenting, while the Biocompound® material failed to prove efficacy. Conclusions It was demonstrated that the new macro-porous polyester mesh stent reduced neointimal hyperplasia more effectively than other commercially available stents.
This article highlights potential health services research approaches focusing on the example of a CRT device coupled with a pulmonary diagnostic and alert function. Although this retrospective analysis holds a number of limitations (e.g., small number of patients in intervention group, cost calculations only from the payer perspective), and despite the need for randomized controlled trials, it was shown that secondary data research in this field is a valuable approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.