We evaluated the use of the turbidimetric HemosIL von Willebrand Factor (VWF) Activity assay (VWF:Act) on the STA-R automated coagulometer (Stago, Asnières, France) for the diagnosis of von Willebrand disease (VWD). For this, we prospectively screened 268 patients. As a second part, we retrospectively assayed 111 patients with well-defined VWD subtype. In the first prospective study, we demonstrate that in most cases of VWD, VWF ristocetin cofactor activity (VWF:RCo) and VWF:Act are highly correlated but that they both cannot be considered a good screening assay when used alone, since they could miss about 25% of VWF abnormalities. However, the association of VWF:Act analysis and the Platelet Function Analyzer-100 (PFA-100) test constitutes an excellent screening strategy. In our second retrospective study concerning VWD subtypes, VWF:RCo and VWF:Act were well correlated but could be very discrepant, especially for some cases of type 2M VWD. We consider that VWF:RCo remains the "reference assay" for VWD subtype classification.
The platelet function analyser (PFA-100) is a biological tool designed to explore primary haemostasis. This system has thus been widely demonstrated as reliable in detecting von Willebrand factor (VWF) deficiency. However, most studies were based on patients benefitting from regular medical care and accurate diagnosis, and it would seem probable that the results were somewhat optimistic, and do not reflect its performances in 'real-world' situations. We have chosen to study the reliability of PFA-100 for screening VWF ristocetin cofactor (VWF:RCo) deficiency. We retrospectively analysed the results (n = 6431) of 4027 patients referred to our centre between October 1997 and June 2013 and in whom PFA-Epi, PFA-ADP, and VWF:RCo activity had been evaluated. We studied the influence of blood group on the results and the performances of each method in a subgroup of 213 patients with genetically confirmed von Willebrand disease. We have shown that the PFA-100 system, in our experience, constitutes an excellent screening test for detecting VWF:RCo deficiency, whatever the clinical situation, in 'real-world' conditions. The negative predictive value (NPV), the positive predictive value, the sensitivity and the specificity were respectively: 0.98, 0.51, 0.98 and 0.40. When values adjusted for blood group are used, NPV and sensitivity are inferior to those using normal values which have not been adjusted for blood group. We have shown the PFA-100 method to be more efficient in screening for VWF deficiency than the VWF:RCo technique.
In this single-center retrospective study, we evaluated the accuracy of laboratory tests in diagnosing acquired von Willebrand syndrome associated with lymphoproliferative disorders in 36 consecutive patients diagnosed at the University Hospital of Nantes, France. We also compared hemostatic treatments in the following groups: 21 patients with Waldenström macroglobulinemia (WM), 14 with monoclonal gammopathy of undetermined significance (MGUS) (10 with IgG-MGUS and 4 with IgM-MGUS), and 1 with IgA multiple myeloma (IgA-MM). The diagnosis was made in 18 (50%) patients during systematic screening, in 6 (17%) during active mild hemorrhage, and in 12 (33%) during an active, severe bleed. Of the laboratory tests studied, only closure times measured on the Platelet Function Analyzer (PFA)-100 device reliably diagnosed the hemostatic problem. There was no relationship between the factor VIII activity (FVIII:C) or von Willebrand factor activity (VWF:RCo) levels and the previous history of hemorrhage described by patients.We studied hemostatic treatment in most patients: IgG-MGUS patients responded well to high-dose intravenous immunoglobulin (IVIg) infusions (1 g/kg per d), although patients with IgM-MGUS did not. Desmopressin infusions were effective in 3 patients with IgG-MGUS and 2 patients with IgM-MGUS when the baseline values were above 10 IU/dL, but levels soon returned to the baseline. The 7 WM patients had a good response to desmopressin. These results confirm the efficacy of IVIg in IgG-MGUS patients and the prominent role of closure time in the diagnosis of acquired von Willebrand syndrome.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.