Green roofs (GRs) are becoming a trend in urban areas, favouring thermal performance of buildings, promoting removal of atmospheric pollutants, and acting as possible water collection spots. Rainwater harvesting systems in buildings can also contribute to the management of stormwater runoff reducing flood peaks. These technologies should be enhanced in Mediterranean countries where water scarcity is increasing and the occurrence of extreme events is becoming very significant, as a result of climate change. An extensive pilot GR with three aromatic plant species, Satureja montana, Thymus caespititius and Thymus pseudolanuginosus, designed to study several parameters affecting rainwater runoff, has been in operation for 12 months. Physico-chemical analyses of roof water runoff (turbidity, pH, conductivity, NH4(+), NO3(-), PO4(3-), chemical oxygen demand) have shown that water was of sufficient quality for non-potable uses in buildings, such as toilet flushing. An innovative approach allowed for the development of an expression to predict a 'monthly runoff coefficient' of the GR system. This parameter is essential when planning and designing GRs combined with rainwater harvesting systems in a Mediterranean climate. This study is a contribution to improving the basis for the design of rainwater harvesting systems in buildings with extensive GRs under a Mediterranean climate.
During the last decades, achieving water efficiency in buildings has increasingly become an important challenge in the scope of sustainability. Water consumption is directly related to individual conduct. Despite the various technological improvements in fixtures and appliances, their performance will be influenced by human preferences and behavior. As a result, the potential for effective water consumption saving is influenced by behavior change as well as water-efficient fixtures and appliances. This work evaluates the impact of user preferences and behavior change on the water-efficient performance of tap aerators in a case study building: the Department of Civil Engineering building of the University of Aveiro, Portugal. Four aerators with different discharge reductions and types were installed in the toilet's washbasins and the user's preferences and behavior change measured through direct and online questionnaires. It was observed that the effective water consumption reduction (15 to 49%) was less than the discharge reduction (30 to 70%), confirming that user factors influence water savings. Water use reductions in the tested range (2.0 to 6.7 l/min) also varied according to gender, with male users using less water than their female counterparts. It was noted that an awareness of sustainability values prevailed amongst the users when confronted with the choice between comfort and water efficiency, although differences were observed in the user preferences regarding the various aerators. When confronted with the information that the lower discharge aerator would contribute to a reduction of about 70% on the water discharge, 25% of the users agreed with its use, even if it resulted in a certain degree of dissatisfaction. In comparison, only 8% of the users completely disagreed with its installation. On average, the water consumption reduction was 46% smaller than the discharge reduction achievable with the aerator alone. This further confirms the user factors inform the degree of water savings that is achievable from water-efficient fittings and fixtures.
In addition to the possible contributions of buildings to mitigating CO 2 emissions, increased attention is being paid to the potential impacts of climate change on urban environments. According to the United Nations, about 54% of the planet's population currently lives in cities, but this percentage is expected to rise to 66% in 2050, which reveals the scale of this issue. This paper develops a reflection on the possible contributions of water-related building installations to mitigate emissions and increase urban area adaptation to the effects of climate change. One of the most promising solutions to facing climate change, which is analysed in detail in this paper, is combining rainwater harvesting systems with green roofs. However, in view of developing the necessary engineering projects, there are insufficient existing studies to estimate the parameters to be used in each location given their climate characteristics, particularly the monthly runoff coefficients, which constitute the key parameter for designing these installations in some regions. Some recent standards present generic theoretical values for designing these combined installations, but they are far from reality in some regions, such as the Mediterranean basin. Therefore, based on the data available in Portugal, this paper reports some of the results obtained from research on the values of the monthly runoff coefficients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.