Objective: To compare the measured values obtained from the plaster model, digital models created by scanning the plaster models and direct intraoral scanning with the values obtained from direct intraoral measurements. Design: This was a prospective clinical study. Setting: The study was conducted in Department of Orthodontics, Saveetha Dental College and Hospital, Tamil Nadu, India. Participants: Ten patients before the start of orthodontic treatment were selected for the study. Methods: A computer-aided design and manufacturing (CAD-CAM) system is an advanced technology that is being adopted in the field of orthodontics for diagnosis, treatment planning and documentation of patient records. Mesiodistal tooth width measurements of first premolars, canines, lateral incisors and central incisors, and transverse width measurement from mesial pit of right first premolar to mesial pit of left first premolar in both maxilla and mandible were obtained from direct intraoral measurement (gold standard), study model obtained from alginate impression, intraoral scanned image, and desktop scanned image of the study model. Descriptive statistics and ANOVA was performed to find the difference in mean among the groups. Results: A P value > 0.05 was obtained in ANOVA indicating that there is no statistically significant difference in the measurements obtained by either of the methods. Conclusion: Conventional stone models and digital models obtained from intraoral scan and desktop scanning of plaster models are clinically reliable as the variations in measurements obtained from these methods were clinically negligible.
Background
In this study, we aimed to evaluate orthodontic mini-implant placement in the maxillary anterior alveolar region by cone beam computed tomography (CBCT) in 15 patients at a single center in South India.
Material/Methods
A total of 15 CBCT scans of orthodontic patients after completion of leveling and aligning stage were included. The thickness of labial alveolar bone, labio-palatal bone, and inter-radicular distance between the maxillary central incisors (U1-U1), maxillary central and lateral incisor (U1–U2), and maxillary lateral incisor and canine (U2–U3) at vertical levels 4 mm, 6 mm, and 8 mm above the interdental cementoenamel junction were measured. Descriptive statistics, ANOVA, and Tukey post hoc tests were done to assess the differences among the groups. An independent
t
test was done to analyze differences by sex.
Results
The thickness of cortical bone in the labial region was higher in the U2–U3 site than in the U1-U1 site, at a height of 4 mm. Also, there was a significant difference between 4 mm and 8 mm heights in the U2–U3 region. No significant difference was noted in bone dimensions among men and women and in the labio-palatal bone thickness among the different sites. The inter-radicular distance was the highest between the U2–U3 site, while it was the lowest in the U1–U2 site.
Conclusions
The findings from this center showed that when CBCT was used to evaluate orthodontic mini-implant placement in the maxillary anterior alveolar region, the U2–U3 and U1-U1 locations at heights between 6 mm to 8 mm apical to the interdental cementoenamel junction were optimal for placement of the mini-implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.