Three-dimensional (3D) printing has become broadly available and can be utilized to customize clamping mechanisms in biomechanical experiments. This report will describe our experience using 3D printed clamps to mount soft tissues from different anatomical regions. The feasibility and potential limitations of the technology will be discussed. Tissues were sourced in a fresh condition, including human skin, ligaments and tendons. Standardized clamps and fixtures were 3D printed and used to mount specimens. In quasi-static tensile tests combined with digital image correlation and fatigue trials we characterized the applicability of the clamping technique. Scanning electron microscopy was utilized to evaluate the specimens to assess the integrity of the extracellular matrix following the mechanical tests. 3D printed clamps showed no signs of clamping-related failure during the quasi-static tests, and intact extracellular matrix was found in the clamping area, at the transition clamping area and the central area from where the strain data was obtained. In the fatigue tests, material slippage was low, allowing for cyclic tests beyond 105 cycles. Comparison to other clamping techniques yields that 3D printed clamps ease and expedite specimen handling, are highly adaptable to specimen geometries and ideal for high-standardization and high-throughput experiments in soft tissue biomechanics.
Current treatments of plantar fasciitis are based on the premise that the Achilles tendon (AT) and plantar fascia (PF) are mechanically directly linked, which is an area of debate. The aim of this study was to assess the morphological relationship between the AT and PF. Nineteen cadaveric feet were x-ray imaged, serially sectioned and plastinated for digital image analyses. Measurements of the AT and PF thicknesses and cross-sectional areas (CSA) were performed at their calcaneal insertion. The fiber continuity was histologically assessed in representative subsamples. Strong correlations exist between the CSA of the AT and PF at calcaneal insertion and the CSA of PF’s insertional length (r = 0.80), and between the CSAs of AT’s and PF’s insertional lengths. Further correlations were observed between AT and PF thicknesses (r = 0.62). This close morphological relationship could, however, not be confirmed through x-ray nor complete fiber continuity in histology. This study provides evidence for a morphometric relationship between the AT and PF, which suggests the presence of a functional relationship between these two structures following the biological key idea that the structure determines the function. The observed morphological correlations substantiate the existing mechanical link between the AT and PF via the posterior calcaneus and might explain why calf stretches are a successful treatment option for plantar heel pain.
BackgroundBiomechanical testing using image-based deformation detection techniques such as digital image correlation (DIC) offer optical contactless methods for strain and displacement measurements of biological tissues. However, given the need of most samples to be speckled for image correlation using sprays, chemical alterations with impact on tissue mechanicals may result. The aim of this study was to assess the impact of such surface coating on the mechanical properties of rat bones, under routine laboratory conditions including multiple freeze-thaw cycles.MethodsTwo groups of rat bones, highly-uniform and mixed-effects, were assigned to six subgroups consisting of three types of surface coating (uncoated, commercially-available water- and solvent-based sprays) and two types of bone conditions (periosteum attached and removed). The mixed-effects group had undergone an additional freeze-thaw cycle at − 20 degrees. All bones underwent a three-point bending test ranging until material failure.ResultsCoating resulted in similar and non-significantly different mechanical properties of rat bones, indicated by elastic moduli, maximum force and bending stress. Scanning electron microscopy showed more pronounced mechanical alterations related to the additional freeze-thaw cycle, with fewer cracks being present in a bone from the highly-uniform group.ConclusionsThis study has concluded that surface coating with water- or solvent-based sprays for enhancing image correlation for DIC and having an additional freeze-thaw cycle do not significantly alter mechanical properties of rat bones. Therefore, this method may be recommended as an effective way of obtaining a speckled pattern.
We aim to discuss an inexpensive method of conducting binocular indirect ophthalmoscopy without the binocular indirect ophthalmoscope headset. This technique only requires the examiner to hold a light source between their eyes and hold a condensing lens at an arm’s length. This may be particularly valuable in resource-poor settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.