This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
Purpose
Anterior lumbar interbody fusion (ALIF) is a well-established alternative to posterior-based interbody fusion techniques, with approach variations, such as retroperitoneal, transperitoneal, open, and laparoscopic well described. Variable rates of complications for each approach have been enumerated in the literature. The purpose of this study was to elucidate the comparative rates of complications across approach type.
Methods
A systematic review of search databases PubMed, Google Scholar, and OVID Medline was made to identify studies related to complication-associated ALIF. PRISMA guidelines were utilised for this review. Meta-analysis was used to compare intraoperative and postoperative complications with ALIF for each approach.
Results
A total of 4575 studies were identified, with 5728 patients across 31 studies included for review following application of inclusion and exclusion criteria. Meta-analysis demonstrated the transperitoneal approach resulted in higher rates of retrograde ejaculation (RE) (p < 0.001; CI = 0.05–0.21) and overall rates of complications (p = 0.05; CI = 0.00–0.23). Rates of RE were higher at the L5/S1 intervertebral level. Rates of vessel injury were not significantly higher in either approach method (p = 0.89; CI = − 0.04–0.07). Rates of visceral injury did not appear to be related to approach method. Laparoscopic approaches resulted in shorter inpatient stays (p = 0.01).
Conclusion
Despite the transperitoneal approach being comparatively underpowered, its use appears to result in a significantly higher rate of intraoperative and postoperative complications, although confounders including use of bone morphogenetic protein (BMP) and spinal level should be considered. Laparoscopic approaches resulted in shorter hospital stays; however, its steep learning curve and longer operative time have deterred surgeons from its widespread adaptation.
Purpose: We evaluate the face, content, and construct validity of a portable hip arthroscopy module in a regional orthopaedic unit. Methods: Participants were recruited from a regional orthopaedic centre, and categorized into novice (0 arthroscopies), intermediate (1-29 arthroscopies), and expert (>50 arthroscopies) groups based on reported experience in arthroscopy. Face and content validity was evaluated by feedback from users immediately following completion of modules. Objective measurements, including time taken and subjective measurements consisting of simulation software metrics including, cam lesion locations attempts, scope strikes on bone, healthy bone burred, and cam lesion burred. Scores achieved by experts were recorded, and the median score was set at the level at which proficiency was demonstrated. Participant feedback on perceived educational use was collected following completion. Results: In total, 20 participant results were included for analysis. Good face and content validity was expressed by participants with previous arthroscopic experience. Number of scope strikes within the simulator-derived metrics accurately discerned between levels of experience. Novices had a mean of 5 strikes per attempt (SD AE5Þ; intermediates a mean of 5.8 strikes (SD AE 4.1). There was a significant difference between expert and novice groups (P ¼ .01), and expert and intermediate groups (P ¼ .002). No significant difference between overall performance scores achieved by participants in expert, intermediate, and novice groups (62% AE 19 vs 55% AE 22 vs 50% AE 23; P ¼ .15). This demonstrates incomplete construct validity of the simulator software-derived metrics. Conclusion: This hip arthroscopy simulator demonstrated acceptable face and content validity, with incomplete construct validity of simulator software metrics. Participants reported high levels of satisfaction with the module, highlighting that the addition of haptic feedback would be beneficial to improve procedural steps. Incorporation of tactile feedback to the modulator components would likely enable the software to accurately delineate between levels of experience.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.