<b><i>Objectives:</i></b> We aimed to determine the accuracy and validity of the Ultrasonic Cardiac Output Monitor (USCOM) measurements of cardiac output (CO) compared to echocardiography in newborn infants, and the inter-rater agreement of USCOM measurements. <b><i>Methods:</i></b> In a single-center study we prospectively evaluated neonates undergoing an echocardiographic evaluation. USCOM measurements of CO were obtained at the pulmonary and aortic valve by 2 physicians blinded to the echocardiographic results. All echocardiographic measurements were performed blinded to USCOM measurements. We first enrolled an ascertainment cohort which was subsequently validated in an independent new cohort. Agreement between echocardiography and USCOM methods was assessed by Bland-Altman analysis. Intra-class correlation coefficients (ICC) assessed the agreement between the 2 operators. The ascertainment cohort correction factors were applied in a second validation cohort and agreement of the calibrated measures evaluated with repeat Bland-Altman comparisons. <b><i>Results:</i></b> A total of 50 infants were enrolled in the initial cohort and 15 in the validation cohort. There was a high degree of correlation between the USCOM operators (ICC = 0.975). USCOM measurements of CO were significantly higher compared to echocardiography (left ventricular output bias 95 ± 52 mL/kg/min and right ventricular output bias 64 ± 30 mL/kg/min). There was no difference in the subgroup of infants with and without a ductus arteriosus. After the correction was applied to the validation cohort, there was no longer a significant difference between the measures. <b><i>Conclusions:</i></b> CO measured by USCOM consistently overestimated the results obtained from echocardiography. USCOM is not adequate to provide absolute estimates of CO. However, it may allow longitudinal hemodynamic assessment of sick neonates.
We present 4 cases of cor triatriatum in whom the diagnosis was correctly made by 2-dimensional transthoracic echocardiography, which showed the supravalvular left atrial membrane that divides the left atrium into 2 chambers. The pulmonary veins were connected normally to the proximal left atrial chamber and the left atrial appendage was connected to the distal left atrial chamber. In 1 patient there was evidence of severe pulmonary venous obstruction to the mitral valve by Doppler examination, while in the other three, there was no venous obstruction. Patients were then examined by real-time 3-dimensional echocardiography (RT3DE, using x4 matrix array transducer connected to Sonos 7500 echocardiographic system Phillips, Andover, Mass, USA). This showed the exact morphology of the membrane and led to cancellation of planed surgical intervention in 1 case in which the membrane was only a broad band crossing the left atrial cavity. In addition to delineating the exact morphology of the intracavitary anomaly, this novel echocardiographic imaging modality should be an additive tool to better understand the natural history of these nonobstructive left atrial membranes via longitudinal follow-up of these patients.
<b><i>Objectives:</i></b> Inhaled nitric oxide (iNO) is an effective pulmonary vasodilator. However, the efficacy of iNO in former premature infants with established bronchopulmonary dysplasia (BPD) has not been studied. This study aimed to determine the efficacy of iNO in reducing pulmonary artery pressure in infants with severe BPD as measured by echocardiography. <b><i>Study Design:</i></b> Prospective, observational study enrolling infants born at less than 32 weeks gestation and in whom (1) iNO therapy was initiated after admission to our institution, or (2) at the outside institution less than 48 h before transfer and received an echocardiogram prior to iNO initiation, and (3) had severe BPD. Data were collected at three time-points: (1) before iNO; (2) 12–48 h after initiation of iNO; and (3) 48–168 h after initiation of iNO. The primary outcome was the effect of iNO on pulmonary artery pressure measured by echocardiography in patients with severe BPD between 48 and 168 h after initiating iNO therapy. <b><i>Results:</i></b> Of 37 enrolled, 81% had echocardiographic evidence of pulmonary arterial hypertension (PAH) before iNO and 56% after 48 h of iNO (<i>p</i> = 0.04). FiO2 requirements were significantly different between time-points (1) and (3) (<i>p</i> = 0.05). There were no significant differences between Tricuspid Annular Plane Systolic Excursion (TAPSE) Z-Scores, time to peak velocity: right ventricular ejection time (TPV:RVET), and ventilator changes. <b><i>Conclusions:</i></b> Although we found a statistically significant reduction of PAH between time-point (1) and (3), future trials are needed to further guide clinical care.
Background: Strain analysis with speckle-tracking echocardiography shows promise as a screening tool for silent myocardial dysfunction in pediatric-onset systemic lupus erythematosus (pSLE). We compared left ventricular (LV) systolic deformation (measured by strain) in children and adolescents with pSLE to controls, and assessed the relationship between strain, disease activity, and other noninvasive measures of cardiovascular health. Methods: Twenty pSLE subjects ages 9-21 underwent comprehensive cardiovascular testing, including 2D speckle-tracking echocardiography, ambulatory blood pressure monitoring (ABPM), peripheral endothelial function testing, pulse wave velocity and analysis, and carotid ultrasound. Longitudinal apical-4 chamber (LS A4C) and midpoint circumferential strain (CS mid) were compared to that of 70 healthy controls using multivariable linear regression. Among pSLE subjects, Pearson correlation coefficients were calculated to evaluate relationships between global longitudinal or circumferential strain and other measures of cardiovascular health. Results: Average SLE disease duration was 3.2 years (standard deviation [SD] 2.1). 2/20 pSLE subjects had persistent disease activity, and only one met criteria for hypertension by ABPM. LS A4C was significantly reduced in pSLE subjects compared to controls (mean −18.3 [SD 3.2] vs −21.8% [SD 2.2], P-value <.001). There was no significant difference in CS mid (−24.8 [SD 3.7] vs −25.7% [SD 3.4], P = .29). Among pSLE subjects, decreased nocturnal blood pressure dipping on ABPM was associated with reduced global circumferential strain (r −0.59, P = .01). Conclusions: Longitudinal myocardial deformation is impaired in pSLE patients despite clinical remission and may represent early myocardial damage. Strain analysis should be considered in addition to standard echocardiographic assessment during follow-up of patients with pSLE.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.