SD-OCT provides a non-invasive method of following long-term retinal changes in mice in vivo. Although rd10 and rd1 mice have mutations in the same gene, they demonstrate significantly different features on SD-OCT.
Previous studies support the textbook model that shape and color are extracted by distinct neurons in primate primary visual cortex (V1). However, rigorous testing of this model requires sampling a larger stimulus space than previously possible. We used stable GCaMP6f expression and 2-photon calcium imaging to probe a very large spatial and chromatic visual stimulus space and map functional microarchitecture of thousands of neurons with single cell resolution. Notable proportions of V1 neurons strongly preferred equiluminant color over achromatic stimuli and were also orientation selective, indicating that orientation and color in V1 are mutually processed by overlapping circuits. Single neurons could precisely and unambiguously code for both color and orientation. Further analyses revealed systematic spatial relationships between color tuning, orientation selectivity, and cytochrome oxidase histology.
PURPOSE. To describe a standardized flood-illuminated adaptive optics (AO) imaging protocol suitable for the clinical setting and to assess sampling methods for measuring cone density.METHODS. Cone density was calculated following three measurement protocols: 50 3 50-lm sampling window values every 0.58 along the horizontal and vertical meridians (fixed-interval method), the mean density of expanding 0.58-wide arcuate areas in the nasal, temporal, superior, and inferior quadrants (arcuate mean method), and the peak cone density of a 50 3 50-lm sampling window within expanding arcuate areas near the meridian (peak density method). Repeated imaging was performed in nine subjects to determine intersession repeatability of cone density. RESULTS.Cone density montages could be created for 67 of the 74 subjects. Image quality was determined to be adequate for automated cone counting for 35 (52%) of the 67 subjects. We found that cone density varied with different sampling methods and regions tested. In the nasal and temporal quadrants, peak density most closely resembled histological data, whereas the arcuate mean and fixed-interval methods tended to underestimate the density compared with histological data. However, in the inferior and superior quadrants, arcuate mean and fixed-interval methods most closely matched histological data, whereas the peak density method overestimated cone density compared with histological data. Intersession repeatability testing showed that repeatability was greatest when sampling by arcuate mean and lowest when sampling by fixed interval. CONCLUSIONS.We show that different methods of sampling can significantly affect cone density measurements. Therefore, care must be taken when interpreting cone density results, even in a normal population.
BackgroundAdaptive optics scanning light ophthalmoscopy (AOSLO) enables direct visualisation of the cone mosaic, with metrics such as cone density and cell spacing used to assess the integrity or health of the mosaic. Here we examined the interobserver and inter-instrument reliability of cone density measurements.MethodsFor the interobserver reliability study, 30 subjects with no vision-limiting pathology were imaged. Three image sequences were acquired at a single parafoveal location and aligned to ensure that the three images were from the same retinal location. Ten observers used a semiautomated algorithm to identify the cones in each image, and this was repeated three times for each image. To assess inter-instrument reliability, 20 subjects were imaged at eight parafoveal locations on one AOSLO, followed by the same set of locations on the second AOSLO. A single observer manually aligned the pairs of images and used the semiautomated algorithm to identify the cones in each image.ResultsBased on a factorial study design model and a variance components model, the interobserver study's largest contribution to variability was the subject (95.72%) while the observer's contribution was only 1.03%. For the inter-instrument study, an average cone density intraclass correlation coefficient (ICC) of between 0.931 and 0.975 was calculated.ConclusionsWith the AOSLOs used here, reliable cone density measurements can be obtained between observers and between instruments. Additional work is needed to determine how these results vary with differences in image quality.
Background Cardiovascular disease is the leading cause of mortality and disability worldwide. A noninvasive test that can detect underlying cardiovascular disease has the potential to identify patients at risk prior to the occurrence of adverse cardiovascular events. We sought to determine whether an easily observed imaging finding indicative of retinal ischemia, which we term ‘ retinal ischemic perivascular lesions’ (RIPLs), could serve as a biomarker for cardiovascular disease. Methods We reviewed optical coherence tomography (OCT) scans of individuals, with no underlying retinal pathology, obtained at UC San Diego Health from July 2014 to July 2019. We identified 84 patients with documented cardiovascular disease and 76 healthy controls. OCT scans were assessed for evidence of RIPLs. In addition, the 10-year atherosclerotic cardiovascular disease (ASCVD) risk calculator was used to risk-stratify the subjects into four different categories. Findings Patients with documented cardiovascular disease had higher number of RIPLs compared to healthy controls (2.8 vs 0.8, p < 0.001). After adjusting for age, sex, smoking history, systolic blood pressure and triglycerides, cholesterol and hemoglobin A1C levels, each RIPL was associated with an odds ratio of having cardiovascular disease of 1·60 (1.09–2>37). The number of RIPLs in individuals with intermediate and high 10-year ASCVD risk scores was higher than in those with low ASCVD risk scores (1.7 vs 0.64, p = 0.02 and 2.9 vs 0.64, p 0.002, respectively). Interpretation The presence of RIPLs, which are anatomical markers of prior retinal ischemic infarcts, is suggestive of coexisting cardiovascular disease. RIPLs detection, obtained from routine retinal scans, may thus provide an additional biomarker to identify patients at risk of developing adverse cardiovascular events. Funding None.
Similar to other organs, the retina relies on tightly regulated perfusion and oxygenation. Previous studies have demonstrated that retinal blood flow is affected in a variety of eye and systemic diseases, including diabetic retinopathy, age-related macular degeneration, and glaucoma. Although measurement of peripheral oxygen saturation has become a standard clinical measurement through the development of pulse oximetry, developing a noninvasive technique to measure retinal oxygen saturation has proven challenging, and retinal oximetry technology currently remains inadequate for reliable clinical use. Here, we review current strategies and approaches, as well as several newer technologies in development, and discuss the future of retinal oximetry.
Purpose The global COVID-19 pandemic has resulted in a renewed focus on the importance of personal protective equipment (PPE) and other interventions to decrease spread of infectious diseases. While several ophthalmology organizations have released guidance on appropriate PPE for surgical procedures and ophthalmology clinics, there is limited experimental evidence demonstrating the efficacy of various interventions that have been suggested. In this study, we evaluate high-risk aspects of the slit-lamp exam and the effect of various PPE interventions, specifically the use of a surgical mask and a slit lamp shield. Design Experimental simulation study Methods Setting: Single-center Study Population Patient Simulation Main outcome measure(s) Presence of particles in the air near or on slit lamp and simulated slit lamp examiner or simulated patient using a fluorescent surrogate of respiratory droplets. Results Simulated coughing without a mask or slit lamp shield resulted in widespread dispersion of fluorescent droplets during the model slit lamp examination. Coughing with a mask resulted in the most significant decrease in droplets, however, particles still escaped from the top of the mask. Coughing with the slit lamp shield alone blocked most of forward particle dispersion; however significant distributions of respiratory droplets were found on the slit lamp joystick and table. Coughing with both mask and slit lamp shield resulted in the least dispersion to the simulated examiner and the simulated patient. Scanning electron microscopy demonstrated particle sizes of 3-100μm. Conclusions Masking has the greatest effect in limiting spread of respiratory droplets, while slit lamp shields and gloves also contribute to limiting exposure to droplets from SARS-CoV-2 during slit lamp examination.
Studies of color perception have led to mechanistic models of how cone-opponent signals from retinal ganglion cells are integrated to generate color appearance. But it is unknown how this hypothesized integration occurs in the brain. Here we show that cone-opponent signals transmitted from retina to primary visual cortex (V1) are integrated through highly organized circuits within V1 to implement the color opponent interactions required for color appearance. Combining intrinsic signal optical imaging (ISI) and 2-photon calcium imaging (2PCI) at single cell resolution, we demonstrate cone-opponent functional domains (COFDs) that combine L/M cone-opponent and S/L + M cone-opponent signals following the rules predicted from psychophysical studies of color perception. These give rise to an orderly organization of hue preferences of the neurons within the COFDs and the generation of hue “pinwheels”. Thus, spatially organized neural circuits mediate an orderly transition from cone-opponency to color appearance that begins in V1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.