From both a fundamental and a clinical point of view, it is necessary to know the distribution of the eye's aberrations in the normal population and to be able to describe them as efficiently as possible. We used a modified Hartmann-Shack wave-front sensor to measure the monochromatic wave aberration of both eyes for 109 normal human subjects across a 5.7-mm pupil. We analyzed the distribution of the eye's aberrations in the population and found that most Zernike modes are relatively uncorrelated with each other across the population. A principal components analysis was applied to our wave-aberration measurements with the resulting principal components providing only a slightly more compact description of the population data than Zernike modes. This indicates that Zernike modes are efficient basis functions for describing the eye's wave aberration. Even though there appears to be a random variation in the eye's aberrations from subject to subject, many aberrations in the left eye were found to be significantly correlated with their counterparts in the right eye.
The objective was to study the relative contribution of the optical aberrations of the cornea and the internal ocular optics (with the crystalline lens as the main component) to overall aberrations in the human eye. Three sets of wave-front aberration data were independently measured in the eyes of young subjects: for the anterior surface of the cornea, the complete eye, and internal ocular optics. The amount of aberration of both the cornea and internal optics was found to be larger than for the complete eye, indicating that the first surface of the cornea and internal optics partially compensate for each other's aberrations and produce an improved retinal image. This result has a number of practical implications. For example, it shows the limitation of corneal topography as a guide for new refractive procedures and provides a strong endorsement of the value of ocular wave-front sensing for those applications.
We studied the age dependence of the relative contributions of the aberrations of the cornea and the internal ocular surfaces to the total aberrations of the eye. We measured the wave-front aberration of the eye with a Hartmann-Shack sensor and the aberrations of the anterior corneal surface from the elevation data provided by a corneal topography system. The aberrations of the internal surfaces were obtained by direct subtraction of the ocular and corneal wave-front data. Measurements were obtained for normal healthy subjects with ages ranging from 20 to 70 years. The magnitude of the RMS wave-front aberration (excluding defocus and astigmatism) of the eye increases more than threefold within the age range considered. However, the aberrations of the anterior corneal surface increase only slightly with age. In most of the younger subjects, total ocular aberrations are lower than corneal aberrations, while in the older subjects the reverse condition occurs. Astigmatism, coma, and spherical aberration of the cornea are larger than in the complete eye in younger subjects, whereas the contrary is true for the older subjects. The internal ocular surfaces compensate, at least in part, for the aberrations associated with the cornea in most younger subjects, but this compensation is not present in the older subjects. These results suggest that the degradation of the ocular optics with age can be explained largely by the loss of the balance between the aberrations of the corneal and the internal surfaces.
To gain more insight into the relationship between foveal and peripheral refractive errors in humans, spheres, cylinders, and their axes were binocularly measured across the visual field in myopic, emmetropic, and hyperopic groups of young subjects. Both automated infrared photorefraction (the "PowerRefractor"; www. plusoptix.de) and a double-pass technique were used because the PowerRefractor provided extensive data from the central 44 deg of the visual field in a very convenient and fast way. Two-dimensional maps for the average cross cylinders and spherical equivalents, as well as for the axes of the power meridians of the cylinders, were created. A small amount of lower-field myopia was detected with a significant vertical gradient in spherical equivalents. In the central visual field there was little difference among the three refractive groups. The established double-pass technique provided complementary data also from the far periphery. At 45 deg eccentricity the double-pass technique revealed relatively more hyperopic spherical equivalents in myopic subjects than in emmetropic subjects [+/-2.73 +/- 2.85 D relative to the fovea, p < 0.01 (+/- standard deviation)] and more myopic spherical equivalents in hyperopic subjects (-3.84 +/- 2.86 D relative to the fovea, p < 0.01). Owing to the pronounced peripheral astigmatism, spherical equivalents (refractions with respect to the plane of the circle of least confusion) became myopic relative to the fovea in all three groups. The finding of general peripheral myopia was unexpected. Its possible roles in foveal refractive development are discussed.
An ideal correcting method, such as a customized contact lens, laser refractive surgery, or adaptive optics, that corrects higher-order aberrations as well as defocus and astigmatism could improve vision. The benefit achieved with this ideal method will be limited by decentration. To estimate the significance of this potential limitation we studied the effect on image quality expected when an ideal correcting method translates or rotates with respect to the eye's pupil. Actual wave aberrations were obtained from ten human eyes for a 7.3-mm pupil with a Shack-Hartmann sensor. We computed the residual aberrations that appear as a result of translation or rotation of an otherwise ideal correction. The model is valid for adaptive optics, contact lenses, and phase plates, but it constitutes only a first approximation to the laser refractive surgery case where tissue removal occurs. Calculations suggest that the typical decentrations will reduce only slightly the optical benefits expected from an ideal correcting method. For typical decentrations the ideal correcting method offers a benefit in modulation 2-4 times higher (1.5-2 times in white light) than with a standard correction of defocus and astigmatism. We obtained analytical expressions that show the impact of translation and rotation on individual Zernike terms. These calculations also reveal which aberrations are most beneficial to correct. We provided practical rules to implement a selective correction depending on the amount of decentration. An experimental study was performed with an aberrated artificial eye corrected with an adaptive optics system, validating the theoretical predictions. The results in a keratoconic subject, also corrected with adaptive optics, showed that important benefits are obtained despite decentrations in highly aberrated eyes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.