The main goal in the treatment of large bone defects is to guarantee a rapid loading of the affected limb. In this paper, the authors proposed a new reconstructive technique that proved to be suitable to reach this purpose through the use of a custom-made biomimetic porous titanium scaffold. An in vivo study was undertaken where a complete critical defect was experimentally created in the diaphysis of the right tibia of twelve sheep and replaced with a five-centimeter porous scaffold of electron beam melting (EBM)-sintered titanium alloy (EBM group n = 6) or a porous hydroxyapatite scaffold (CONTROL group, n = 6). After surgery, the sheep were allowed to move freely in the barns. The outcome was monitored for up to 12 months by periodical X-ray and clinical examination. All animals in the CONTROL group were euthanized for humane reasons within the first month after surgery due to the onset of plate bending due to mechanical overload. Nine months after surgery, X-ray imaging showed the complete integration of the titanium implant in the tibia diaphysis and remodeling of the periosteal callus, with a well-defined cortical bone. At 12 months, sheep were euthanized, and the tibia were harvested and subjected to histological analysis. This showed bone tissue formations with bone trabeculae bridging titanium trabeculae, evidencing an optimal tissue-metal interaction. Our results show that EBM-sintered titanium devices, if used to repair critical bone defects in a large animal model, can guarantee immediate body weight-bearing, a rapid functional recovery, and a good osseointegration. The porous hydroxyapatite scaffolds proved to be not suitable in this model of large bone defect due to their known poor mechanical properties.
PurposeSeveral studies have investigated effectiveness of fibrin spray or bipolar sealer to control peri-operative bleeding and reduce the need for blood transfusion, but a direct comparison between the two methods has not been previously performed. We conducted a prospective randomised trial, with standard electrocautery as a control group.MethodsIn our investigation, 95 patients were randomised to one of three parallel groups receiving (1) 10 mL of topical fibrin spray before closure, (2) haemostasis with radiofrequency energy using a bipolar sealer, and (3) standard electrocautery. All patients and staff apart from the surgeons were blinded until data analysis was complete. Peri-operative blood loss has been calculated using a formula described by Ward and Gross (considering estimated patient blood volume, pre- and post-operative haemoglobin and haematocrit levels), with mention of eventual blood re-infusion or transfusion, at given intervals from surgery (6, 24, 48, 72 hours).ResultsMean blood loss was lower for both methods investigated, compared to the control group at every time interval considered, although differences were stronger for fibrin spray [Quixil]. Mean blood saving at the given intervals from surgery (6–24–48–72 hours) was respectively 96 ml, 129 ml, 296 ml, and 121 ml for bipolar sealer [Aquamantys] and 235 ml, 368 ml, 642 ml, and 490 ml for fibrin spray. These results are statistically significant (p = 0.05) for fibrin spray at every interval compared to control values, while a significance is detectable for bipolar sealer only at 48 hours after surgery.ConclusionsThe fibrin spray group had the best performance in terms of blood loss, significantly reduced in comparison with the control group and bipolar sealer group. Blood loss reduction for the bipolar sealer was remarkable only at 48 hours, compared with the control group. Blood loss reduction for fibrin spray was significant at every time interval considered. Differences between the two treatments investigated and the control group narrowed slightly at 72 hours, as an expression of spontaneous homeostasis. Notable is the fact that blood volume saved with fibrin spray at 24 and 48 hours is comparable to the volume of at least one blood unit. A cost-effectiveness analysis should be considered in term of expense, biological risks (related to blood transfusion or human-derived products use) and bleeding-related complications.
Septic arthritis/tenosynovitis in the horse can have life-threatening consequences. The purpose of this cross-sectional retrospective study was to describe ultrasound characteristics of septic arthritis/tenosynovitis in a group of horses. Diagnosis of septic arthritis/tenosynovitis was based on historical and clinical findings as well as the results of the synovial fluid analysis and/or positive synovial culture. Ultrasonographic findings recorded were degree of joint/sheath effusion, degree of synovial membrane thickening, echogenicity of the synovial fluid, and presence of hyperechogenic spots and fibrinous loculations. Ultrasonographic findings were tested for dependence on the cause of sepsis, time between admission and beginning of clinical signs, and the white blood cell counts in the synovial fluid. Thirty-eight horses with confirmed septic arthritis/tenosynovitis of 43 joints/sheaths were included. Degree of effusion was marked in 81.4% of cases, mild in 16.3%, and absent in 2.3%. Synovial thickening was mild in 30.9% of cases and moderate/severe in 69.1%. Synovial fluid was anechogenic in 45.2% of cases and echogenic in 54.8%. Hyperechogenic spots were identified in 32.5% of structures and fibrinous loculations in 64.3%. Relationships between the degree of synovial effusion, degree of the synovial thickening, presence of fibrinous loculations, and the time between admission and beginning of clinical signs were identified, as well as between the presence of fibrinous loculations and the cause of sepsis (P ≤ 0.05). Findings indicated that ultrasonographic findings of septic arthritis/tenosynovitis may vary in horses, and may be influenced by time between admission and beginning of clinical signs.
This paper describes 19 cases of lateral meniscal cysts treated arthroscopically using an outside-in technique. In all patients, a horizontal or radial lesion (or both) of the meniscus was present. After the meniscal lesion was arthroscopically removed, the cyst was decompressed both from inside and percutaneously from outside with a motorized instrument introduced through a transmeniscal approach. The follow-up ranged from 2 to 5 years with an average of 3.3 years. On the basis of the evaluation scale developed by Cerullo et al. (1991), the results were rated excellent or good in 17 patients and fair in 2. No patient had cyst recurrence. The computed tomography follow-up examination, done in 10 of the 19 patients after an average of 3 years, showed a good remodeling of the meniscus. One of the two patients with a fair result had hypermobility of the posterior horn of the lateral meniscus due to the resection of the meniscal tissue overlying the popliteus tendon, whereas the other had pain and patellar crepitation owing to a preexisting patellofemoral abnormality.
We report data about the effects of intraperitoneal (i.p.) injection of specific pathogen-free (SPF) porcine Sertoli cells (SeC) encapsulated into clinical grade alginate-based microcapsules (SeC-MC) on muscles of chronic and presymptomatic dystrophic, mdx mice. Mdx mouse is the best characterized animal model of Duchenne muscular dystrophy (DMD), an X-linked lethal myopathy due to mutation in the gene of dystrophin, which is crucial for myofiber integrity during muscle contraction. Our data show that three weeks after i.p. injection of SeC-MC significantly reduced adipose and fibrous tissue deposition, reduced macrophage infiltrate, and reduced numbers of damaged myofibers are found in muscles of 12-month-old mdx mice, which reproduce chronic DMD conditions. Compared with muscles of mock-treated mdx mice muscles of SeC-MC-treated mice show upregulation of the dystrophin paralogue, utrophin which is localized to the periphery of myofibers. Moreover, our data show that i.p. injection of SeC-MC into presymptomatic, 2-week-old mdx mice, although not fully preventing myofiber degeneration, results in protection against myofiber necrosis and muscle inflammation. Extensive discussion of these data can be found in Ref. [1].
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.