Background: Unity Elekta is a unique magnetic resonance (MR)-linac that conjugates a 1.5 Tesla MR unit with a 7 MV flattening filter free accelerator.A prospective observational study for the clinical use of Elekta Unity is currently ongoing in our department. Herein, we present our preliminary report on the feasibility, quality of life, and patientreported outcomes measures (PROMs) for localized prostate cancer (PC) treated with stereotactic body radiotherapy (SBRT). Methods: The SBRT protocol consisted of a 35 Gy schedule delivered in 5 fractions within 2 weeks. Toxicity and quality of life (QoL) were assessed at baseline and after treatment using the Common Terminology Criteria for Adverse Events v5.0, International Prostatic Symptoms Score (IPSS), ICIQ-SF, IIEF-5, and EORTC-QLQ-C30 and PR-25 questionnaires. Results: Between October 2019 and January 2020, 25 patients with localized PC were recruited. The median age was 68 years (range, 54-82); 4 were low risk, 11 favorable intermediate risk (IR) and 10 unfavorable IR. Median iPSA was 6.8 ng/ml (range, 1-19), and 9 of these patients (36%) received concurrent androgen deprivation therapy. Median prostate volume was 36 cc (range, 20-61); median baseline IPSS was 5 (range, 0-10). Median time for fraction was 53 min (range, 34-86); adaptive strategy with daily critical structure and target re-contouring and daily replanning (adapt to shape) was performed in all cases. No grade ≥ 3 adverse event was observed, three patients (12%) reported grade 2 acute genitourinary toxicity (urinary frequency, urinary tract pain and urinary retention), while only one patient reported mild rectal pain. No relevant deteriorations were reported in PROMs.
Background: The assessment of organ motion is a crucial feature for prostate stereotactic body radiotherapy (SBRT). Rectal spacer may represent a helpful device in order to outdistance rectal wall from clinical target, but its impact on organ motion is still a matter of debate. MRI-Linac is a new frontier in radiation oncology as it allows a superior visualization of the real-time anatomy of the patient and the current highest level of adaptive radiotherapy. Methods: We present data regarding a total of 100 fractions in 20 patients who underwent MRI-guided prostate SBRT for low-to-intermediate risk prostate cancer with or without spacer. Translational and rotational shifts were computed on the pre-and post-treatment MRI acquisitions referring to the delivery position for antero-posterior, latero-lateral and cranio-caudal direction, and assessed using the Mann-Whitney U-Test. Results: All patients were treated with a five sessions schedule (35 Gy/5fx) using MRI-Linac for a median fraction treatment time of 50 min (range, 46-65). In the entire study sample, median rotational displacement was 0.1°in cranio-caudal, − 0.002°in latero-lateral and 0.01°in antero-posterior direction; median translational shift was 0.11 mm in cranio-caudal, − 0.24 mm in latero-lateral and − 0.22 mm in antero-posterior. A significant difference between spacer and no-spacer patients in terms of rotational shifts in the antero-posterior direction (p = 0.033) was observed; also for translational shifts a positive trend was detected in antero-posterior direction (p = 0.07), although with no statistical significance. We observed statistically significant differences in the pre-treatment planning phase in favor of the spacer cohort for several rectum dose constraints: rectum V32Gy < 5% (p = 0.001), V28 Gy < 10% (p = 0.001) and V18Gy < 35% (p = 0.039). Also for bladder V35 Gy < 1 cc, the use of spacer provided a dosimetric advantage compared to the no-spacer subpopulation (p = 0.04). Furthermore, PTV V33.2Gy > 95% was higher in the spacer cohort compared to the no-spacer one (p = 0.036).
Alongi (2021) Daily dosimetric variation between image-guided volumetric modulated arc radiotherapy and MR-guided daily adaptive radiotherapy for prostate cancer stereotactic body radiotherapy,
Objective: The main aim of the current analysis was to explore the hypothetical advantages using rectal spacer during 1.5T MR-guided and daily-adapted PC SBRT compared to a no-rectal spacer hydrogel cohort of patients. Methods: The SBRT-protocol consisted of a 35 Gy schedule delivered in five fractions. Herein we present a dosimetric analysis between spacer and no-spacer patients. Furthermore, treatment tolerability and feasibility were preliminarily assessed according to clinicians-reported outcomes at the end of treatment and patient-reported outcomes measures (PROMs) in both arms. Toxicity and quality of life were assessed at baseline and after treatment using the Common Terminology Criteria for Adverse Events v5.0, International Prostatic Symptoms Score, ICIQ-SF, IIEF-5, and EORTC-QLQ-C30 and PR-25 questionnaires. Results: 120 plans (pre- and daily adaptive SBRT planning) were analyzed in 20 patients (10 patients in spacer group and 10 patients in no-spacer group) treated using 1.5T MR-guided adaptive SBRT. Statistically significant dosimetric advantages were observed in favor of the spacer insertion, improving the PTV coverage in terms of V33.2Gy >95% and PTV 37.5 Gy <2% mainly during daily-adapted SBRT. Also, rectum V32, V28 and V18Gy and bladder V35Gy <1 cc were significantly reduced in the spacer cohort. Concerning the PROMS, all questionnaires showed no difference between the pre- and post-SBRT evaluation in both arms, excepting the physical functioning item of EORTC QLQ-C30 questionnaire that was declined in the no-spacer group. Conclusion: These preliminary results strongly suggest the adoption of peri-rectal spacer due to dosimetric advantages not only for rectal sparing but also for target coverage. Longer follow-up is required to validate the clinical impact in terms of Clinicians-reported toxicity and PROMs. Advances in knowledge: This the first experience reporting preliminary data concerning the potential dosimetric impact of rectal hydrogel spacer on MR-guided SBRT for prostate cancer.
Two aged dogs with chronic obstructive airway disease were evaluated because of intermittent swelling of the ventral cervical region. Radiographs made at expiration and caudal positioning of the forelimbs allowed identification of intermittent cervical lung herniation of the left and right cranial lung lobe in both dogs. Pulmonary hyperinflation, increased expiratory effort, and chronic coughing were considered responsible for the lung herniation. Cervical lung hernia should be included in the differential diagnoses of intermittent cervical swelling in dogs with chronic respiratory disorders associated with increased expiratory effort and chronic coughing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.