We studied friction and stick-slip phenomena on bare and lubricated silicon samples by measuring the torsional contact resonances of atomic force microscope cantilevers. A piezoelectric transducer placed below the sample generates in-plane sample surface vibrations which excite torsional vibrations of the cantilever. The resonance frequencies of the vibrating beam depend on the tip-sample forces. At low lateral surface amplitudes the cantilever behaves like a linear oscillator with viscous damping. Above a critical surface amplitude, typically 0.2 nm, the amplitude maximum of the resonance curves does not increase any more and the shape of the resonance curves changes, indicating the onset of sliding friction. The critical amplitude increases with increasing static cantilever load. For a bare silicon sample it is higher than for the lubricated silicon. Microslip known from macroscopic contacts causes energy dissipation in the atomic force microscope tip-contact before sliding friction sets i
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.