Glioblastoma (GBM) is an aggressive and incurable primary brain tumor that causes severe neurologic, cognitive, and psychologic symptoms. Symptoms are caused and exacerbated by the infiltrative properties of GBM cells, which enable them to pervade the healthy brain and disrupt normal function. Recent research has indicated that although radiotherapy (RT) remains the most effective component of multimodality therapy for patients with GBM, it can provoke a more infiltrative phenotype in GBM cells that survive treatment. Here, we demonstrate an essential role of the actin-myosin regulatory kinase myotonic dystrophy kinase-related CDC42-binding kinase (MRCK) in mediating the proinvasive effects of radiation. MRCKmediated invasion occurred via downstream signaling to effector molecules MYPT1 and MLC2. MRCK was activated by clinically relevant doses per fraction of radiation, and this activation was concomitant with an increase in GBM cell motility and invasion. Furthermore, ablation of MRCK activity either by RNAi or by inhibition with the novel small-molecule inhibitor BDP-9066 prevented radiationdriven increases in motility both in vitro and in a clinically relevant orthotopic xenograft model of GBM. Crucially, treatment with BDP-9066 in combination with RT significantly increased survival in this model and markedly reduced infiltration of the contralateral cerebral hemisphere. Significance: An effective new strategy for the treatment of glioblastoma uses a novel, anti-invasive chemotherapeutic to prevent infiltration of the normal brain by glioblastoma cells.
Background Conventional MRI fails to detect regions of glioblastoma cell infiltration beyond the contrast‐enhanced T1 solid tumor region, with infiltrating tumor cells often migrating along host blood vessels. Purpose To quantitatively and qualitatively analyze the correlation between perfusion MRI signal and tumor cell density in order to assess whether local perfusion perturbation could provide a useful biomarker of glioblastoma cell infiltration. Study Type Animal model. Subjects Mice bearing orthotopic glioblastoma xenografts generated from a patient‐derived glioblastoma cell line. Field Strength/Sequences 7T perfusion images acquired using a high signal‐to‐noise ratio (SNR) multiple boli arterial spin labeling sequence were compared with conventional MRI (T1/T2 weighted, contrast‐enhanced T1, diffusion‐weighted, and apparent diffusion coefficient). Assessment Immunohistochemistry sections were stained for human leukocyte antigen (probing human‐derived tumor cells). To achieve quantitative MRI‐tissue comparison, multiple histological slices cut in the MRI plane were stacked to produce tumor cell density maps acting as a “ground truth.” Statistical Tests Sensitivity, specificity, accuracy, and Dice similarity indices were calculated and a two‐tailed, paired t‐test used for statistical analysis. Results High comparison test results (Dice 0.62–0.72, Accuracy 0.86–0.88, Sensitivity 0.51–0.7, and Specificity 0.92–0.97) indicate a good segmentation for all imaging modalities and highlight the quality of the MRI tissue assessment protocol. Perfusion imaging exhibits higher sensitivity (0.7) than conventional MRI (0.51–0.61). MRI/histology voxel‐to‐voxel comparison revealed a negative correlation between tumor cell infiltration and perfusion at the tumor margins (P = 0.0004). Data Conclusion These results demonstrate the ability of perfusion imaging to probe regions of low tumor cell infiltration while confirming the sensitivity limitations of conventional imaging modalities. The quantitative relationship between tumor cell density and perfusion identified in and beyond the edematous T2 hyperintensity region surrounding macroscopic tumor could be used to detect marginal tumor cell infiltration with greater accuracy. Level of Evidence: 1 Technical stage: 2 J. Magn. Reson. Imaging 2019;50:529–540.
Spatially resolved Pulsed Field Gradient (PFG) velocimetry techniques can provide precious information concerning flow through opaque systems, including rocks. This velocimetry data is used to enhance flow models in a wide range of systems, from oil behaviour in reservoir rocks to contaminant transport in aquifers. Phase-shift velocimetry is the fastest way to produce velocity maps but critical issues have been reported when studying flow through rocks and porous media, leading to inaccurate results. Combining PFG measurements for flow through Bentheimer sandstone with simulations, we demonstrate that asymmetries in the molecular displacement distributions within each voxel are the main source of phase-shift velocimetry errors. We show that when flow-related average molecular displacements are negligible compared to self-diffusion ones, symmetric displacement distributions can be obtained while phase measurement noise is minimised. We elaborate a complete method for the production of accurate phase-shift velocimetry maps in rocks and low porosity media and demonstrate its validity for a range of flow rates. This development of accurate phase-shift velocimetry now enables more rapid and accurate velocity analysis, potentially helping to inform both industrial applications and theoretical models.
The counter-regulatory axis, Angiotensin Converting Enzyme 2, Angiotensin-(1-7), Mas receptor (ACE2/Ang-1-7/MasR), of the renin angiotensin system (RAS) is a potential therapeutic target in stroke, with Ang-(1-7) reported to have neuroprotective effects in pre-clinical stroke models. Here, an extensive investigation of the functional and mechanistic effects of Ang-(1-7) was performed in a rodent model of stroke. Using longitudinal magnetic resonance imaging (MRI) it was observed that central administration of Ang-(1-7) following transient middle cerebral artery occlusion (MCAO) increased the amount of tissue salvage compared to reperfusion alone. This protective effect was not due to early changes in blood brain barrier (BBB) permeability, microglia activation or inflammatory gene expression. However, increases in NADPH oxidase 1 (Nox1) mRNA expression were observed in the treatment group compared to control. In order to determine whether Ang-(1-7) has direct cerebrovascular effects, laser speckle contrast imaging (LSCI) was performed to measure dynamic changes in cortical perfusion following reperfusion. Delivery of Ang-(1-7) did not have any effect on cortical perfusion following reperfusion however; it showed an indication to prevent the ‘steal phenomenon’ within the contralateral hemisphere. The comprehensive series of studies have demonstrated a moderate protective effect of Ang-(1-7) when given alongside reperfusion to increase tissue salvage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.