The purpose of this study was (a) to describe the snatch technique in terms of kinematic and external and internal kinetic parameters, and (b) to compare the results for athletes of different groups and weight categories. By means of three-dimensional film analysis and measurements of ground reaction forces during the 1985 World Championships in Sweden, it was possible to analyze the spatial movements and to calculate joint moments of force in each leg. Concerning the kinematics, a snatch technique starting with a strong pull toward the lifter could be established. The most interesting kinetic results are that the knee joint moments are relatively small (one third of the hip joint moments of force) and do not correlate very well with the total load. The best lifters seem able to limit the knee joint moment by precise control of the knee position with respect to the ground reaction force. Altogether, the results concerning the internal kinetic parameters question the logic of the classical division of the lifting technique into phases according to external kinetic parameters.
Force enhancement during and following muscle stretch has been observed for electrically and voluntarily activated human muscle. However, especially for voluntary contractions, the latter observation has only been made for adductor pollicis and the ankle joint muscles, but not for large muscles like quadriceps femoris. Therefore, the aim of this study was to investigate the effects of active muscle stretch on force production for maximal voluntary contractions of in vivo human quadriceps femoris (n = 15). Peak torques during and torques at the end of stretch, torques following stretch, and passive torques following muscle deactivation were compared to the isometric torques at corresponding muscle length. In addition, muscle activation of rectus femoris, vastus medialis and vastus lateralis was obtained using surface EMG. Stretches with different amplitudes (15, 25 and 35 degrees at a velocity of 60 degrees s(-1)) were performed on the plateau region and the descending limb of the force-length relation in a random order. Data analysis showed four main results: (1) peak torques did not occur at the end of the stretch, but torques at the end of the stretch exceeded the corresponding isometric torque; (2) there was no significant force enhancement following muscle stretch, but a small significant passive force enhancement persisted for all stretch conditions; (3) forces during and following stretch were independent of stretch amplitude; (4) muscle activation during and following muscle stretch was significantly reduced. In conclusion, although our results showed passive force enhancement, we could not provide direct evidence that there is active force enhancement in voluntarily activated human quadriceps femoris.
Force plates represent the "gold standard" in measuring running kinetics to predict performance or to identify the sources of running-related injuries. As these measurements are generally limited to laboratory analyses, wireless high-quality sensors for measuring in the field are needed. This work analysed the accuracy and precision of a new wireless insole forcesensor for quantifying running-related kinetic parameters. Vertical ground reaction force (GRF) was simultaneously measured with pit-mounted force plates (1 kHz) and loadsol sensors (100 Hz) under unshod forefoot and rearfoot running-step conditions. GRF data collections were repeated four times, each separated by 30 min treadmill running, to test influence of extended use. A repeated-measures ANOVA was used to identify differences between measurement devices. Additionally, mean bias and Bland-Altman limits of agreement (LoA) were calculated. We found a significant difference (p < .05) in ground contact time, peak force, and force rate, while there was no difference in parameters impulse, time to peak, and negative force rate. There was no influence of time point of measurement. The mean bias of ground contact time, impulse, peak force, and time to peak ranged between 0.6% and 3.4%, demonstrating high accuracy of loadsol devices for these parameters. For these same parameters, the LoA analysis showed that 95% of all measurement differences between insole and force plate measurements were less than 12%, demonstrating high precision of the sensors. However, highly dynamic behaviour of GRF, such as force rate, is not yet sufficiently resolved by the insole devices, which is likely explained by the low sampling rate.
• We investigated the association of paraspinal muscle fat fraction based on chemical shift encoding-based water-fat MRI with isometric strength measurements in healthy subjects. • Erector spinae muscle PDFF correlated significantly with relative muscle strength. • PDFF measurements improved prediction of paraspinal muscle strength beyond CSA.
Magnetic resonance–based assessment of quadriceps muscle fat has been proposed as surrogate marker in sarcopenia, osteoarthritis, and neuromuscular disorders. We presently investigated the association of quadriceps muscle fat with isometric strength measurements in healthy males using chemical shift encoding-based water-fat magnetic resonance imaging. Intermuscular adipose tissue fraction and intramuscular proton density fat fraction correlated significantly (P < 0.05) with isometric strength (up to r = −0.83 and −0.87, respectively). Reproducibility of intermuscular adipose tissue fraction and intramuscular proton density fat fraction was 1.5% and 5.7%, respectively.
The standard Plug-in-Gait (PiG) protocol used in three-dimensional gait analysis is prone to errors arising from inconsistent anatomical landmark identification and knee axis malalignment. The purpose of this study was to estimate the reliability and accuracy of a custom made lower body protocol (MA) compared with the PiG protocol. Twenty-fve subjects volunteered to evaluate the intertrial reliability. In addition, intersession reliability was examined in 10 participants. An indirect indicator of accuracy according to the knee varus/valgus and flexion/extension range of motion (ROM) was used. Regarding frontal plane knee angles and moments as well as transverse plane motions in the knee and hip joint, the intersession errors were lower for the MA compared with the standard approach. In reference to the knee joint angle cross-talk, the MA produced 4.7° more knee flexion/extension ROM and resulted in 6.5° less knee varus/valgus ROM in the frontal plane. Therefore, the MA tested in this study produced a more accurate and reliable knee joint axis compared with the PiG protocol. These results are especially important for measuring frontal and transverse plane gait parameters.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.