Instrumented earbuds equipped with accelerometers were developed in response to limitations of currently used running wearables regarding sensor location and feedback delivery. The aim of this study was to assess test–retest reliability, face validity and concurrent validity for cadence and stance time in running. Participants wore an instrumented earbud (new method) while running on a treadmill with embedded force-plates (well-established method). They ran at a range of running speeds and performed several instructed head movements while running at a comfortable speed. Cadence and stance time were derived from raw earbud and force-plate data and compared within and between both methods using t-tests, ICC and Bland–Altman analysis. Test–retest reliability was good-to-excellent for both methods. Face validity was demonstrated for both methods, with cadence and stance time varying with speed in to-be-expected directions. Between-methods agreement for cadence was excellent for all speeds and instructed head movements. For stance time, agreement was good-to-excellent for all conditions, except while running at 13 km/h and shaking the head. Overall, the measurement of cadence and stance time using an accelerometer embedded in a wireless earbud showed good test–retest reliability, face validity and concurrent validity, indicating that instrumented earbuds may provide a promising alternative to currently used wearable systems.
A change in cadence during walking or running might be indicated for a variety of reasons, among which mobility improvement and injury prevention. In a within-subject study design, we examined whether walking or running cadences are modulated best by means of step-based or stride-based auditory pacing. Sixteen experienced runners walked and ran on a treadmill while synchronizing with step-based and stride-based pacing at slow, preferred and fast pacing frequencies in synchronization-perturbation and synchronization-continuation conditions. We quantified the variability of the relative phase between pacing cues and footfalls and the responses to perturbations in the pacing signal as measures of coordinative stability; the more stable the auditory-motor coordination, the stronger the modulating effect of pacing. Furthermore, we quantified the deviation from the prescribed cadence after removal of the pacing signal as a measure of internalization of this cadence. Synchronization was achieved less often in running, especially at slow pacing frequencies. If synchronization was achieved, coordinative stability was similar, and the paced cadence was well internalized for preferred and fast pacing frequencies. Step-based pacing led to more stable auditory-motor coordination than stride-based pacing in both walking and running. We therefore concluded that step-based auditory pacing deserves preference as a means to modulate cadence in walking and running.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.