Abstract-Although atherosclerosis starts in early life, evidence on risk factors and atherosclerosis in individuals aged <45 years is scarce. Therefore, we studied the relationship between risk factors, common carotid intima-media thickness (CIMT), and first-time cardiovascular events in adults aged <45 years. Our study population consisted of 3067 adults aged <45 years free from symptomatic cardiovascular disease at baseline, derived from 6 cohorts that are part of the USE-IMT initiative, an individual participant data meta-analysis of general-population-based cohort studies evaluating CIMT measurements. Information on risk factors, CIMT measurements, and follow-up of the combined end point (first-time myocardial infarction or stroke) was obtained. We assessed the relationship between risk factors and CIMT and the relationship between CIMT and first-time myocardial infarction or stroke using a multivariable linear mixedeffects model and a Cox proportional-hazards model, respectively. During a follow-up of 16.3 years, 55 first-time myocardial infarctions or strokes occurred. Median CIMT was 0.63 mm. Of the risk factors under study, age, sex, diastolic blood pressure, body mass index, total cholesterol, and high-density lipoprotein cholesterol related to CIMT. Furthermore, CIMT related to first-time myocardial infarction or stroke with a hazard ratio of 1.40 per SD increase in CIMT, independent of risk factors (95% confidence interval, 1.11-1.76). CIMT may be a valuable marker for cardiovascular risk in adults aged <45 years who are not yet eligible for standard cardiovascular risk screening. This is especially relevant in those with an increased, unfavorable risk factor burden. Currently, preclinical identification of high-risk individuals is based on risk assessment using scoring systems of aggregated cardiovascular risk factors.3,4 Nevertheless, risk factor profiling alone cannot conclusively identify individuals at highest risk for developing clinically manifest CVD. Furthermore, these scoring systems are mostly used in individuals aged >40 years. Moreover, associations between risk factors and clinically manifest CVD have primarily been established in people aged >45 years. Data from long-term observational studies on cardiovascular risk assessment in younger adults are limited. 6Finding proxies that reliably detect subclinical atherosclerosis early in life is important because preventive regimens started early in life might delay the development of clinically manifest CVD. The American Heart Association acknowledges this and emphasizes on increased evaluation of noninvasive methods for cardiovascular risk assessment in the young to achieve increased preclinical identification of high-risk individuals years before clinically manifest CVD arises. 7Carotid intima-media thickness (CIMT), measured noninvasively using B-mode ultrasonography, is an established marker for subclinical atherosclerosis. Research demonstrates that already from a young age onward, CIMT relates to various cardiovascular risk factors. [8...
ObjectiveTo determine inter-observer and inter-examination variability of manual attenuation measurements of the vertebrae in low-dose unenhanced chest computed tomography (CT).MethodsThree hundred and sixty-seven lung cancer screening trial participants who underwent baseline and repeat unenhanced low-dose CT after 3 months because of an indeterminate lung nodule were included. The CT attenuation value of the first lumbar vertebrae (L1) was measured in all CTs by one observer to obtain inter-examination reliability. Six observers performed measurements in 100 randomly selected CTs to determine agreement with limits of agreement and Bland-Altman plots and reliability with intraclass correlation coefficients (ICCs). Reclassification analyses were performed using a threshold of 110 HU to define osteoporosis.ResultsInter-examination reliability was excellent with an ICC of 0.92 (p < 0.001). Inter-examination limits of agreement ranged from -26 to 28 HU with a mean difference of 1 ± 14 HU. Inter-observer reliability ICCs ranged from 0.70 to 0.91. Inter-examination variability led to 11.2 % reclassification of participants and inter-observer variability led to 22.1 % reclassification.ConclusionsVertebral attenuation values can be manually quantified with good to excellent inter-examination and inter-observer reliability on unenhanced low-dose chest CT. This information is valuable for early detection of osteoporosis on low-dose chest CT.Key Points• Vertebral attenuation values can be manually quantified on low-dose unenhanced CT reliably.• Vertebral attenuation measurements may be helpful in detecting subclinical low bone density.• This could become of importance in the detection of osteoporosis.Electronic supplementary materialThe online version of this article (doi:10.1007/s00330-015-4145-x) contains supplementary material, which is available to authorized users.
BackgroundPre-clinical detection of atherosclerosis enables personalized preventive strategies in asymptomatic individuals. Cardiovascular magnetic resonance (CMR) has evolved as an attractive imaging modality for studying atherosclerosis in vivo. Yet, the majority of aortic CMR studies and proposed sequences to date have been performed at 1.5 tesla using 2D BB techniques and a slice thickness of 4–5 mm. Here, we evaluate for the first time the reproducibility of an isotropic, T1-weighted, three-dimensional, black-blood, CMR VISTA sequence (3D-T1-BB-VISTA) for quantification of aortic wall characteristics in healthy, young adults.MethodsIn 20 healthy, young adults (10 males, mean age 31.3 years) of the AMBITYON cohort study the descending thoracic aorta was imaged with a 3.0 T MR system using the 3D-T1-BB-VISTA sequence. The inter-scan, inter-rater and intra-rater reproducibility of aortic lumen, total vessel and wall area and mean and maximum wall thickness was evaluated using Bland-Altman analyses and Intraclass Correlation Coefficients (ICC). Based on these findings, sample sizes for detecting differences in aortic wall characteristics between groups were calculated.ResultsFor each studied parameter, the inter-scan, inter-rater and intra-rater reproducibility was excellent as indicated by narrow limits of agreement and high ICCs (ranging from 0.76 to 0.99). Sample sizes required to detect a 5 % difference in aortic wall characteristics between two groups were 203, 126, 136, 68 and 153 per group for lumen area, total vessel area and vessel wall area and for mean and maximum vessel wall thickness, respectively.ConclusionThe 3D-T1-BB-VISTA sequence provides excellent reproducibility for quantification of aortic wall characteristics and can detect small differences between groups with reasonable sample sizes. Hence, it may be a valuable tool for assessment of the subtle vascular wall changes of early atherosclerosis in asymptomatic populations.Electronic supplementary materialThe online version of this article (doi:10.1186/s12968-016-0237-2) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.