The validation process resulted in a revised 30-item AddiQoL questionnaire and an eight-item AddiQoL short version with good psychometric properties and high reliability.
BackgroundA loss of adequate Situation Awareness (SA) may play a major role in the genesis of critical incidents in anesthesia and critical care. This observational study aimed to determine the frequency of SA errors in cases of a critical incident reporting system (CIRS).MethodsTwo experts independently reviewed 200 cases from the German Anesthesia CIRS. For inclusion, reports had to be related to anesthesia or critical care for an individual patient and take place in an in-hospital setting. Based on the SA framework, the frequency of SA errors was determined. Representative cases were analyzed qualitatively to illustrate the role of SA for decision-making.ResultsSA errors were identified in 81.5 %. Predominantly, errors occurred on the levels of perception (38.0 %) and comprehension (31.5 %). Errors on the level of projection played a minor role (12.0 %). The qualitative analysis of selected cases illustrates the crucial role of SA for decision-making and performance.ConclusionsSA errors are very frequent in critical incidents reported in a CIRS. The SA taxonomy was suitable to provide mechanistic insights into the central role of SA for decision-making and thus, patient safety.
Quality of life was significantly lower in female patients and in those with manifestation at older ages. With more autoimmune comorbidities, the quality of life scores dropped. The most important factor, however, was latency between first symptoms and diagnosis that affected patients' quality of life even years after manifestation of the disease. These results confirm and extend previous observations and emphasize the importance of a timely diagnosis. Therefore, medical awareness for this rare but easily treatable disorder needs to be sharpened.
Background: Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Methods: Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3-5 days.Results: In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Conclusions: Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.