To evaluate the association between Flash Glucose Monitoring (FLASH) frequency and glycemic parameters during real-life circumstances in the Netherlands. Methods: Obtained glucose readings were de-identified and uploaded to a dedicated database when FLASH reading devices were connected to internet. Data between September 2014 and March 2020, comprising 16,331 analyzable readers (163,762 sensors) were analyzed. Scan rate per reader was determined and each reader was sorted into 20 equally sized rank ordered groups (n = 817 each). Results: Users performed a median of 11.5 ] scans per day. Those in the lowest and highest ventiles scanned on average 3.7 and 40.0 times per day and had an eHbA1c of 8.6% (71 mmol/mol) and 6.9% (52 mmol/mol), respectively. Increasing scan rates were associated with more time in target range (3.9-10 mmol/L), less time in hyperglycemia (>10 mmol/L), and a lower standard deviation of glucose. An eHbA1c of 7.0% (53 mmol/mol) translated in approximately 65% time in target range, 30% time in hyperglycemia and 5% time in hypoglycemia (<3.9 mmol/L). Conclusions: These outcomes among Dutch FLASH users suggest that with higher scan rate glycemic control improves.
Aims To identify factors predicting HbA1c reduction in patients with diabetes mellitus (DM) using FreeStyle Libre Flash Glucose Monitoring (FSL-FGM). Methods Data from a 12-month prospective nation-wide FSL registry were used and analysed with multivariable regression. For the present study we included patients with hypoglycaemia unawareness or unexpected hypoglycaemias (n = 566) and persons who did not reach acceptable glycaemic control (HbA1c > 70 mmol/mol (8.5%)) (n = 294). People with other indications for use, such as sensation loss of the fingers or individuals already using FSL-FGM or rtCGM, were excluded (37%). Results Eight hundred and sixty persons (55% male with a mean age of 46.7 (±16.4) years) were included. Baseline HbA1c was 65.1 (±14.5) mmol/mol (8.1 ± 1.3%), 75% of the patients had type 1 DM and 37% had microvascular complications. Data concerning HbA1c was present for 482 (56.0%) at 6 months and 423 (49.2%) persons at 12 months. A significant reduction in HbA1c (≥5 mmol/mol (0.5%)) was present in 187 (22%) persons. For these persons, median HbA1c reduction was −9.0 [−13.0, −4.0] mmol/mol (−0.82 [−1.19, −0.37]%) at 6 months and −9.0 [−15.0, −7.0] mmol/mol (−0.82 [−1.37, −0.64]%) at 12 months. In multivariable regression analysis with age, gender and SF-12 physical and mental component scores as covariates, only baseline HbA1c was significant: −0.319 (SE 0.025; p < 0.001; R 2 = 0.240 for the model). In exploratory analysis among subgroups with different indications for FSL-FGM use (hypoglycaemia unawareness or persistently high HbA1c) and persons with a significant HbA1c decrease over the study period, baseline HbA1c remained the only significant predictor. Conclusions Among the variables we analysed in the present study, only high HbA1c at baseline predicts significant HbA1c reduction during FSL-CGM use.
IntroductionThe FreeStyle Libre (FSL) is a flash glucose monitoring (FGM) system. The Flash Monitor Register in the Netherlands (FLARE-NL-4) study previously demonstrated the positive effects of FSL-FGM use during 1 year on glycemic control, quality of life and disease burden among persons with diabetes mellitus (DM). The present follow-up study assesses the effects of FSL-FGM after 2 years.Research design and methodsPatients included in the FLARE-NL-4 study who continued FSL-FGM during the 1-year study period were invited to participate (n=687). Data were collected using questionnaires (the 12-Item Short Form Health Survey version 2 (SF-12v2) and the EuroQol 5-Dimension 3-Level (EQ-5D-3L) for quality of life), including self-reported hemoglobin A1c (HbA1c).ResultsA total of 342 patients agreed to participate: mean age 48.0 (±15.6) years, 52% men and 79.5% with type 1 DM. HbA1c decreased from 60.7 (95% CI 59.1 to 62.3) mmol/mol before use of FSL-FGM to 57.3 (95% CI 55.8 to 58.8) mmol/mol after 1 year and 57.8 (95% CI 56.0 to 59.5) mmol/mol after 2 years. At the end of the 2-year follow-up period, 260 (76%) persons were still using the FSL-FGM and 82 (24%) had stopped. The main reason for stopping FSL-FGM was financial constraints (55%). Concerning the whole 2-year period, there was a significant decrease in HbA1c among persons who continued use of FSL-FGM (−3.5 mmol/mol, 95% CI −6.4 to –0.7), while HbA1c was unaltered compared with baseline among persons who stopped FSL-FGM (−2.4 mmol/mol, 95% CI −7.5 to 2.7): difference between groups 2.2 (95% CI −1.3 to 5.8) mmol/mol. After 2 years, persons who continued use of FSL-FGM had higher SF-12 mental component score and higher EQ-5D Dutch tariff score and felt less often anxious or depressed compared with persons who discontinued FSL-FGM.ConclusionsAlthough the considerable number of non-responders limits generalizability, this study suggests that persons who continue to use FSL-FGM for 2 years may experience sustained improvement in glycemic control and quality of life.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.