Pregnancy-related variables recorded in administrative databases or derived from algorithms based on two or more databases were found to be highly valid as compared to the medical chart among asthmatic women.
Objectives and hypothesesAdherence to inhaled corticosteroids (ICS) is a major issue in asthma. This study aimed to estimate the accuracy of the days’ supply and number of refills allowed, variables recorded in Québec claims databases and used to estimate adherence, and to develop correction factors, if required. We hypothesised that the accuracy of the days’ supply for ICS would be low whereas the accuracy of the number of refills allowed would be high.Setting40 community pharmacies in Québec (Canada) and a medication registry.ParticipantsWe collected data for 1108 ICS original prescriptions stored in the 40 pharmacies (sample 1), and we obtained a second sample of 2676 ICS prescriptions selected from reMed, a medication registry (sample 2).Primary and secondary outcomesWe estimated the concordance of the days’ supply and number of refills between Québec claims databases and the original prescription from sample 1. We developed a correction factor for the days’ supply in sample 1 and validated it in sample 2. Analyses were stratified by age: 0–11 and 12–64 years.ResultsIn sample 1, the concordance for the days’ supply was 39.6% (95% CI 37.6% to 41.6%) in those aged 0–11 years and 56% (54.9% to 57.2%) in those aged 12–64 years. The concordance increased to 59.4% (58.2% to 60.5%) in those aged 0–11 years and 74.2% (73.5% to 74.9%) in those aged 12–64 years after applying the correction factors in sample 2. The concordance for the refills allowed was 92.1% (91% to 93.1%) in those aged 0–11 years and 93.1% (92.5% to 93.7%) in those aged 12–64 years in sample 1.ConclusionsThe accuracy of the days’ supply was moderate among those aged 0–11 years and substantial among those aged 12–64 years after applying the correction factors. The accuracy of the number of refills was almost perfect in both groups.
While there currently is some degree of evidence to support the safety of ICS use during pregnancy, this review highlights the limited statistical power of several studies published in this area.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.