Prolonged sedentary behaviour has been associated with various detrimental health risks. Workplace sitting is particularly important, providing it occupies majority of total daily sedentary behaviour among desk-based employees. The aim of this systematic review and meta-analysis was to examine the effectiveness of workplace interventions overall, and according to different intervention strategies (educational/behavioural, environmental and multi-component interventions) for reducing sitting among white-collar working adults. Articles published through December 2015 were identified in five online databases and manual searches. Twenty-six controlled intervention studies published between 2003 and 2015 of 4568 working adults were included. All 26 studies were presented qualitatively, and 21 studies with a control group without any intervention were included in the meta-analysis. The pooled intervention effect showed a significant workplace sitting reduction of -39.6 min/8-h workday (95% confidence interval [CI]: -51.7, -27.5), favouring the intervention group. Multi-component interventions reported the greatest workplace sitting reduction (-88.8 min/8-h workday; 95% CI: -132.7, -44.9), followed by environmental (-72.8 min/8-h workday; 95% CI: -104.9, -40.6) and educational/behavioural strategies -15.5 min/8-h workday (95% CI:-22.9,-8.2). Our study found consistent evidence for intervention effectiveness in reducing workplace sitting, particularly for multi-component and environmental strategies. Methodologically rigorous studies using standardized and objectively determined outcomes are warranted. © 2016 World Obesity.
ObjectiveThe Global Physical Activity Questionnaire (GPAQ) was originally designed to be interviewer-administered by the World Health Organization in assessing physical activity. The main aim of this study was to compare the psychometric properties of a self-administered GPAQ with the original interviewer-administered approach. Additionally, this study explored whether using different accelerometry-based physical activity bout definitions might affect the questionnaire’s validity.MethodsA total of 110 participants were recruited and randomly allocated to an interviewer- (n = 56) or a self-administered (n = 54) group for test-retest reliability, of which 108 participants who met the wear time criteria were included in the validity study. Reliability was assessed by administration of questionnaires twice with a one-week interval. Criterion validity was assessed by comparing against seven-day accelerometer measures. Two definitions for accelerometry-data scoring were employed: (1) total-min of activity, and (2) 10-min bout.ResultsParticipants had similar baseline characteristics in both administration groups and no significant difference was found between the two formats in terms of validity (correlations between the GPAQ and accelerometer). For validity, the GPAQ demonstrated fair-to-moderate correlations for moderate-to-vigorous physical activity (MVPA) for self-administration (r s = 0.30) and interviewer-administration (r s = 0.46). Findings were similar when considering 10-min activity bouts in the accelerometer analysis for MVPA (r s = 0.29 vs. 0.42 for self vs. interviewer). Within each mode of administration, the strongest correlations were observed for vigorous-intensity activity. However, Bland-Altman plots illustrated bias toward overestimation for higher levels of MVPA, vigorous- and moderate-intensity activities, and underestimation for lower levels of these measures. Reliability for MVPA revealed moderate correlations (r s = 0.61 vs. 0.63 for self vs. interviewer).ConclusionsOur findings showed comparability between both self- and interviewer-administration modes of the GPAQ. The GPAQ in general but especially the self-administered version may offer a relatively inexpensive method for measuring physical activity of various types and at different domains. However, there may be bias in the GPAQ measurements depending on the overall physical activity. It is advisable to incorporate accelerometers in future studies, particularly when measuring different intensities of physical activity.
IntroductionAccelerometers are commonly used to assess physical activity. Consumer activity trackers have become increasingly popular today, such as the Fitbit. This study aimed to compare the average number of steps per day using the wrist-worn Fitbit Flex and waist-worn ActiGraph (wGT3X-BT) in free-living conditions.Methods104 adult participants (n = 35 males; n = 69 females) were asked to wear a Fitbit Flex and an ActiGraph concurrently for 7 days. Daily step counts were used to classify inactive (<10,000 steps) and active (≥10,000 steps) days, which is one of the commonly used physical activity guidelines to maintain health. Proportion of agreement between physical activity categorizations from ActiGraph and Fitbit Flex was assessed. Statistical analyses included Spearman’s rho, intraclass correlation (ICC), median absolute percentage error (MAPE), Kappa statistics, and Bland-Altman plots. Analyses were performed among all participants, by each step-defined daily physical activity category and gender.ResultsThe median average steps/day recorded by Fitbit Flex and ActiGraph were 10193 and 8812, respectively. Strong positive correlations and agreement were found for all participants, both genders, as well as daily physical activity categories (Spearman's rho: 0.76–0.91; ICC: 0.73–0.87). The MAPE was: 15.5% (95% confidence interval [CI]: 5.8–28.1%) for overall steps, 16.9% (6.8–30.3%) vs. 15.1% (4.5–27.3%) in males and females, and 20.4% (8.7–35.9%) vs. 9.6% (1.0–18.4%) during inactive days and active days. Bland-Altman plot indicated a median overestimation of 1300 steps/day by the Fitbit Flex in all participants. Fitbit Flex and ActiGraph respectively classified 51.5% and 37.5% of the days as active (Kappa: 0.66).ConclusionsThere were high correlations and agreement in steps between Fitbit Flex and ActiGraph. However, findings suggested discrepancies in steps between devices. This imposed a challenge that needs to be considered when using Fibit Flex in research and health promotion programs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.