Ankylosing spondylitis (AS) is a chronic, inflammatory rheumatic disease. The spine becomes rigid from the occiput to the sacrum, leading to a stooped position. This study aims at evaluating AS subjects gait alterations. Twenty-four subjects were evaluated: 12 normal and 12 pathologic in stabilized anti-TNF-alpha treatment (mean age 49.42 (10.47), 25.44 (3.19) and mean body mass index 55.75 (3.19), 23.73 (2.7), respectively). Physical examination and gait analysis were performed. A motion capture system synchronized with two force plates was used. Three-dimensional kinematics and kinetics of trunk, pelvis, hip, knee and ankle were determined during gait. A trend towards reduction was found in gait velocity and stride length. Gait analysis results showed statistically significant alterations in the sagittal plane at each joint for AS patients (P < 0.049). Hip and knee joint extension moments showed a statistically significant reduction (P < 0.044). At the ankle joint, a decreased plantarflexion was assessed (P < 0.048) together with the absence of the heel rocker. Gait analysis, through gait alterations identification, allowed planning-specific rehabilitation intervention aimed to prevent patients' stiffness together with improve balance and avoid muscles' fatigue.
BackgroundStroke is often associated with balance deficits that increase the risk of falls and may lead to severe mobility disfunctions or death. The purpose of this study is to establish the relation between the outcome of instrumented posturography and of the most commonly used clinical balance tests, and investigate their role for obtaining reliable feedback on stroke patients’ balance impairment.MethodsRomberg test was performed on 20 subjects, 10 hemiplegic post-stroke subjects (SS, 69.4 ± 8.2 years old) and 10 control subjects (CS, 61.6 ± 8.6 years old), with 1 Bertec force plate. The following parameters were estimated from the centre of pressure (CoP) trajectory, which can be used to define subjects’ performance during the balance task: sway area; ellipse (containing 95% of the data); mean CoP path and velocity in the anterior-posterior and medio-lateral directions. The following clinical scales and tests were administered to the subjects: Tinetti Balance test (TB); Berg Balance test (BBT); Time up and go test (TUG), Fugl-Meyer (lower limbs) (FM), Motricity Index (lower limbs), Trunk Control Test, Functional Independence Measure. Comparison between SS and CS subjects was performed by using the Student t-test. The Pearson Correlation coefficient was computed between instrumental and clinical parameters.ResultsMean ± standard deviation for the balance scales scores of SS were: 12.5 ± 3.6 for TB, 42.9 ± 13.1 for BBT, 24 s and 75 cent ± 25 s and 70 cent for TUG. Correlation was found among some CoP parameters and both BBT and TUG in the eyes open and closed conditions (0.9 ≤ R ≤ 0.8). Sway area correlated only with TUG. Statistically significant differences were found between SS and CS in all CoP parameters in eyes open condition (p < 0.04); whereas in eyes closed condition only CoP path and velocity (p < 0.02) differed significantly.ConclusionsCorrelation was found only among some of the clinical and instrumental balance outcomes, indicating that they might measure different aspects of balance control. Consistently with previous findings in healthy and pathological subjects, our results suggest that instrumented posturography should be recommended for use in clinical practice in addition to clinical functional tests.
BackgroundAnkylosing spondylitis is a major chronic rheumatic disease that predominantly affects axial joints, determining a rigid spine from the occiput to the sacrum. The dorsal hyperkyphosis may induce the patients to stand in a stooped position with consequent restriction in patients’ daily living activities. The aim of this study was to develop a method for quantitatively and objectively assessing both balance and posture and their mutual relationship in ankylosing spondylitis subjects.MethodsThe data of 12 healthy and 12 ankylosing spondylitis subjects (treated with anti-TNF-α stabilized), with a mean age of 51.42 and 49.42 years; mean BMI of 23.08 and 25.44 kg/m2 were collected. Subjects underwent a morphological examination of the spinal mobility by means of a pocket compass needle goniometer, together with an evaluation of both spinal and hip mobility (Bath Ankylosing Spondylitis Metrology Index), and disease activity (Bath Ankylosing Spondylitis Disease Activity Index). Quantitative evaluation of kinematics and balance were performed through a six cameras stereophotogrammetric system and a force plate. Kinematic models together with a test for evaluating balance in different eye level conditions were developed. Head protrusion, trunk flexion-extension, pelvic tilt, hip-knee-ankle flexion-extension were evaluated during Romberg Test, together with centre of pressure parameters.ResultsEach subject was able to accomplish the required task. Subjects’ were comparable for demographic parameters. A significant increment was observed in ankylosing spondylitis subjects for knee joint angle with the target placed at each eye level on both sides (p < 0.042). When considering the pelvic tilt angle a statistically significant reduction was found with the target placed respectively at 10° (p = 0.034) and at 30° (p = 0.019) less than eye level. Furthermore in ankylosing spondylitis subjects both hip (p = 0.048) and ankle (p = 0.029) joints angles differs significantly. When considering the posturographic parameters significant differences were observed for ellipse, center of pressure path and mean velocity (p < 0.04). Goniometric evaluation revealed significant increment of thoracic kyphosis reduction of cervical and lumbar range of motion compared to healthy subjects.ConclusionsOur findings confirm the need to investigate both balance and posture in ankylosing spondylitis subjects. This methodology could help clinicians to plan rehabilitation treatments.
Objective: The object of the study was to evaluate the efficacy of Proprioceptive Focal Stimulation on Gait in middle—advanced Parkinson (PD) patients by a crossover, randomized, double Blind double dummy study using Equistasi®, a nano-technological device of the dimension of a plaster which generates High Frequency Vibration (FV).Background: The efficacy of Gait Analysis (GA) on evaluating gait modification on Parkinson's disease (PD) Patients is already well-known. Therefore, GA was recorded in a group of PD patients using Equistasi® device and its placebo.Methods: Forty PD patients on optimal therapy were enrolled in the study. Patients were randomly assigned to receive active or sham stimulation for 8 weeks and, following a wash-out period, switched to an additional 8-week period with the reverse intervention. GA was performed at baseline and at the end of both 8-weeks treatment periods Clinical state was monitored by MDUPDRS part III.Results: Active stimulation induced a significant improvement in Mean Velocity (Velocity), Stride Length (SL), Stance (STA), and Double Support (DST) percentage, both in left and right stride. The ANOVA analysis using H&Y stage as a factor, showed that DST and MDUPDRS III scores improved significantly more in the more severely affected subjects.Conclusions: The findings obtained in this randomized controlled study show the efficacy of mechanical focal vibration, as stimulation of the proprioceptive system, in PD and encourage further investigation. The effect of the device on more severe patients may open a new possibility to identify the most appropriate candidate for the management of gait disturbances and postural instability with FV delivered with Equistasi®.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.