This pilot study aimed to assess the safety and feasibility of an EMG-driven rehabilitation robot in patients with Post-Viral Fatigue (PVF) syndrome after COVID-19. The participants were randomly assigned to two groups (IG—intervention group and CG—control group) in an inpatient neurological rehabilitation unit. Both groups were assessed on admission and after six weeks of rehabilitation. Rehabilitation was carried out six days a week for six weeks. The patients in the IG performed additional training using an EMG rehabilitation robot. Muscle fatigue was assessed using an EMG rehabilitation robot; secondary outcomes were changes in hand grip strength, Fatigue Assessment Scale, and functional assessment scales (Functional Independence Measure, Barthel Index). Both groups improved in terms of the majority of measured parameters comparing pre- and post-intervention results, except muscle fatigue. Muscle fatigue scores presented non-significant improvement in the IG and non-significant deterioration in the CG. Using an EMG rehabilitation robot in patients with PVF can be feasible and safe. To ascertain the effectiveness of such interventions, more studies are needed, particularly involving a larger sample and also assessing the participants’ cognitive performance.
Joint position sense (JPS) is the awareness of joint location in space, indicating accuracy and precision of the movement. Therefore, the aim of the present study is to determine the reliability of active and passive JPS assessment regarding the knee joint. This was carried out using the Luna EMG rehabilitation robot. Further analysis assessed whether the examination of only the dominant site is justified and if there are differences between sites. The study comprised 24 healthy male participants aged 24.13 ± 2.82 years, performing sports at a recreational level. Using the Luna EMG rehabilitation robot, JPS tests were performed for the right and left knees during flexion and extension in active and passive mode, in two separate sessions with a 1-week interval. Both knee flexion and extension in active and passive modes demonstrated high reliability (ICC = 0.866–0.982; SEM = 0.63–0.31). The mean JPS angle error did not differ significantly between the right and left lower limbs (p < 0.05); however, no between-limb correlation was noted (r = 0.21–0.34; p > 0.05). The Bland–Altman plots showed that the between-limb bias was minimal, with relatively wide limits of agreement. Therefore, it was concluded that the Luna EMG rehabilitation robot is a reliable tool for active and passive knee JPS assessment. In our study, JPS angle error did not differ significantly between left and right sides; however, the slight asymmetry was observed (visible in broad level of agreement exceeding 5° in Bland–Altman plots), what may suggest that in healthy subjects, e.g., active athletes, proprioception should always be assessed on both sides.
Background and Objectives: Application of the EMG-driven robotic training in everyday therapeutic processes is a modern and innovative form of neurorehabilitation among patients after stroke. Active participation of the patient contributes to significantly higher activation of the sensorimotor network during active motor control rather than during passive movement. The study objective was to determine the effect of electromyographic triggering (EMG-triggered) robotic rehabilitation device treatment on walking, muscle force, and spasticity after an ischemic stroke. Materials and Methods: A total of 60 participants with impaired motor function and gait after subacute stroke were included in the study. Each patient was randomly assigned to an intervention or control group (IG or CG). All patients, except standard therapy, underwent 1 additional session of therapy per day, 5 days a week for 6 weeks. IG had 30 min of training on the robot, while CG received exercises on the lower limb rotor. The subjects were assessed with Timed Up and Go Test (TUG), Ashworth scale, knee range of motion (ROM), Lovett Scale, and tight circumference at baseline and at weeks 2, 4, and 6. Results: For seven parameters, the values credibly increased between consecutive measurements, and for the Ashworth scale, they credibly decreased. The biggest changes were observed for the measurements made with Lovett scale. The average thigh circumference as measured 5 and 15 cm above the knee increased credibly more in the robot condition, as compared to control condition. Additionally, the decrease in Ashworth values over time, although statistically credible in both groups, was credibly higher in the robot condition. Conclusion: The inclusion of the EMG-triggered neurorehabilitation robot in the patient’s daily rehabilitation plan has a positive effect on outcomes of the treatment. Both proposed rehabilitation protocols significantly improved patients’ condition regarding all measured outcomes, but the spasticity and thigh circumference improved significantly better in the robotic group in comparison to controls.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.