Implementation of environmental cleaning and disinfection has been shown to reduce the incidences of healthcare-associated infections. The effect of an enhanced strategy for terminal room disinfection, applying the pulsed xenon-based ultraviolet light no-touch disinfection systems (PX-UVC) after the current standard operating protocol (SOP) was evaluated. In a teaching hospital, the effectiveness in reducing the total bacterial count (TBC) and in eliminating high-concern microorganisms was assessed on five high-touch surfaces in different critical areas, immediately pre- and post-cleaning and disinfection procedures (345 sampling sites). PX-UVC showed only 18% (15/85) of positive samples after treatment compared to 63% (72/115) after SOP. The effectiveness of PX-UVC was also observed in the absence of manual cleaning and application of a chemical disinfectant. According to the hygienic standards proposed by the Italian Workers Compensation Authority, 9 of 80 (11%) surfaces in operating rooms showed TBC ≥15 CFU/24 cm2 after the SOP, while all samples were compliant applying the SOP plus PX-UVC disinfection. Clostridium difficile (CD) spores and Klebsiella pneumoniae (KPC) were isolated only after the SOP. The implementation of the standard cleaning and disinfection procedure with the integration of the PX-UVC treatment had effective results in both the reduction of hygiene failures and in control environmental contamination by high-concern microorganisms.
Serratia marcescens belongs to the family Enterobacteriaceae, which is commonly found in water, soil, animals, insects, plants. Although S. marcescens displays relatively low virulence, it causes nosocomial infections and outbreaks in severely immunocompromised or critically ill patients, particularly in settings such as intensive care units (ICUs), especially neonatal units (NICUs). This microorganism gives rise to a wide range of clinical manifestations in newborns: from asymptomatic colonization to keratitis, conjunctivitis, urinary tract infections, pneumonia, surgical wound infections, sepsis, bloodstream infection and meningitis. The most frequent site of infection is the bloodstream, followed by the respiratory apparatus and the gastrointestinal tract. Strains of S. marcescens involved in epidemic events have frequently proved to be multi-resistant. Indeed, this species displays intrinsic resistance to several classes of antibiotics. Often, the specific source of the infection cannot be identified. However, the contaminated hands of healthcare workers are believed to be a major vehicle of its transmission. In neonatal intensive care units, colonized or infected newborns are the main potential source of S. marcescens, particularly in the respiratory apparatus, but also in the gastrointestinal tract. The early identification of colonized or infected patients and the prompt implementation of infection control measures, particularly rigorous hand hygiene and contact precautions, are essential in order to curb the spread of infection.
The fungal concentrations recorded in the present study are comparable to those recorded in other studies conducted in hospital environments and are considerably lower than those seen in other indoor environments that are not air conditioned. These findings demonstrate the effectiveness of air-handling systems in reducing fungal contamination.
In Italy, more than 3 million people annually sustain a domestic injury; the elderly experience it the most. From a healthcare perspective, elderly falls are a major clinical issue with an outgrowing socioeconomic burden. The aim of the study was to evaluate the epidemiology of injurious falls in a community dwelling population, admitted to the emergency room (ER) because of a domestic injury, to assess the socioeconomic burden. Seventy-four hospitalized patients among 227 were examined. Falls represented the main cause of admittance to the ER; the average cost for fall-related hospitalization was of €5479.09.
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.
Any disinfection method needs to be adjusted/fine-tuned in individual hospitals in order to maintain satisfactory results over time, and only a locally adapted evidence-based approach allows assessment of the efficacy and disadvantages of the control measures.
These results reveal a high level of contamination of aerators by various species of gram-negative opportunists that are potentially very dangerous for immunocompromised patients and, therefore, the need to improve the management of these devices.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.