Background Optic neuritis (ON) is the most prevalent manifestation of pediatric multiple sclerosis (MSped) and myelin-oligodendrocyte glycoprotein antibody-associated disease (MOGADped) in children > 6 years. In this study, we investigated retinal atrophy patterns and diagnostic accuracy of optical coherence tomography (OCT) in differentiating between both diseases after the first ON episode. Methods Patients were retrospectively identified in eight tertial referral centers. OCT, VEP and high/low-contrast visual acuity (HCVA/LCVA) have been investigated > 6 months after the first ON. Prevalence of pathological OCT findings was identified based on data of 144 age-matched healthy controls. Results Thirteen MOGADped (10.7 ± 4.2 years, F:M 8:5, 21 ON eyes) and 21 MSped (14.3 ± 2.4 years, F:M 19:2, 24 ON eyes) patients were recruited. We observed a significantly more profound atrophy of both peripapillary and macular retinal nerve fiber layer in MOGADped compared to MSped (pRNFL global: 68.2 ± 16.9 vs. 89.4 ± 12.3 µm, p < 0.001; mRNFL: 0.12 ± 0.01 vs. 0.14 ± 0.01 mm3, p < 0.001). Neither other macular layers nor P100 latency differed. MOGADped developed global atrophy affecting all peripapillary segments, while MSped displayed predominantly temporal thinning. Nasal pRNFL allowed differentiation between both diseases with the highest diagnostic accuracy (AUC = 0.902, cutoff < 62.5 µm, 90.5% sensitivity and 70.8% specificity for MOGADped). OCT was also substantially more sensitive compared to VEP in identification of ON eyes in MOGAD (pathological findings in 90% vs. 14%, p = 0.016). Conclusion First MOGAD-ON results in a more severe global peripapillary atrophy compared to predominantly temporal thinning in MS-ON. Nasal pRNFL allows differentiation between both diseases with the highest accuracy, supporting the additional diagnostic value of OCT in children with ON.
Background: High-resolution optical coherence tomography (OCT) allows the detection of macular pathology and involvement of the optic nerve in a wide spectrum of diseases. For the differentiation of diseased and healthy status, normal values of retinal layer segmentation are critical. Yet, normative values mostly cover adult populations with only sparse data for paediatric cohorts. We present data of retinal layer characteristics via OCT in a healthy paediatric cohort.Methods: This prospective cross-sectional study screened 75 healthy children (male=42, female=33, range 4-17 years) without visual problems. OCT was performed with a peripapillary ring and macula scan protocol to determine paediatric normative values for routine parameters (peripapillary retinal nerve fibre layer thickness (pRNFL), total macular volume (TMV), macular retinal thickness (RT)). The macula scan (6mm grid) was segmented using the device-inherent automated segmentation software (Heidelberg Eye Explorer) for retinal layers: RNFL, ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) in 9 segments each and mean of the 9 segments.Results: We obtained OCT data of 72 children with mean age 12.49 years (standard deviation, SD, 2.18; minimum 3.93). Mean global pRNFL was 102.20 μm (SD 8.24), mean TMV 8.81 mm3 (0.30) and mean RT (all segments) 318.22 μm (10.19). Segmented macular retinal layer thicknesses (mean of all segments) were: RNFL 27.67 μm (2.14), GCL 41.94 μm (2.50), IPL 34.97 μm (2.10), INL 35.18 μm (2.15), OPL 29.06 μm (2.24), ONL 68.35 μm (6.20).Conclusion: The OCT is a useful non-invasive imaging technique for the examination of the retina in children with short duration, high imaging resolution and no known adverse effects. Normative values may serve as a comparator for different neuropaediatric disorders and are first presented with this study using an up-to-date and standardized OCT imaging technique.
Background High-resolution optical coherence tomography (OCT) allows the detection of macular pathology and involvement of the optic nerve in a wide spectrum of diseases. For the differentiation of diseased and healthy status, normal values of retinal layer segmentation are critical. Yet, normative values mostly cover adult populations with only sparse data for paediatric cohorts. We present data of retinal layer characteristics via OCT in a healthy paediatric cohort. Methods This prospective cross-sectional study screened 75 healthy children (male = 42, female = 33, range 4–17 years) without visual problems. OCT was performed with a peripapillary ring and macula scan protocol to determine paediatric normative values for routine parameters (peripapillary retinal nerve fibre layer thickness (pRNFL), total macular volume (TMV), macular retinal thickness (RT)). The macula scan (6mm grid) was segmented using the device-inherent automated segmentation software (Heidelberg Eye Explorer) for retinal layers: RNFL, ganglion cell layer (GCL), inner plexiform layer (IPL), inner nuclear layer (INL), outer plexiform layer (OPL), outer nuclear layer (ONL) in 9 segments each and mean of the 9 segments. Results We obtained OCT data of 72 children with mean age 12.49 years (standard deviation, SD, 2.18; minimum 3.93). Mean global pRNFL was 102.20 μm (SD 8.24), mean TMV 8.81 mm3 (0.30) and mean RT (all segments) 318.22 μm (10.19). Segmented macular retinal layer thicknesses (mean of all segments) were: RNFL 27.67 μm (2.14), GCL 41.94 μm (2.50), IPL 34.97 μm (2.10), INL 35.18 μm (2.15), OPL 29.06 μm (2.24), ONL 68.35 μm (6.20). Conclusion The OCT is a useful non-invasive imaging technique for the examination of the retina in children with short duration, high imaging resolution and no known adverse effects. Normative values may serve as a comparator for different neuropaediatric disorders and are first presented with this study using an up-to-date and standardized OCT imaging technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.