BACKGROUND: Left ventricular assist device (LVAD) therapy improves the hemodynamics of advanced heart failure patients. However, it is unknown whether hemodynamic optimization improves clinical outcomes. The aim of this study was to investigate whether hemodynamic optimization reduces hospital readmission rate in LVAD patients. METHODS AND RESULTS: LVAD patients undergoing an invasive hemodynamic ramp test were prospectively enrolled and followed for 1 year. LVAD speed was optimized using a ramp test, targeting the following goals: central venous pressure <12 mm Hg, pulmonary capillary wedge pressure <18 mm Hg, and cardiac index >2.2 L/(min•m 2). The frequency and cause of hospital readmissions were compared between patients who achieved (optimized group) or did not achieve (nonoptimized group) these goals. Eighty-eight outpatients (median 61 years old, 53 male) underwent ramp testing 236 days after LVAD implantation, and 54 (61%) had optimized hemodynamics after LVAD speed adjustment. One-year survival after the ramp study was comparable in both groups (89% versus 88%). The total hospital readmission rate was lower in the optimized group compared with the nonoptimized group (1.15 versus 2.86 events/y, P<0.001). This result was predominantly because of a reduction in the heart failure readmission rate in the optimized group (0.08 versus 0.71 events/y, P=0.016). CONCLUSIONS: LVAD patients, in whom hemodynamics were optimized, had a significantly lower rate of hospital readmissions, primarily because of fewer heart failure admissions. These findings highlight the importance of achieving hemodynamic optimization in LVAD patients.
Aims Left ventricular assist device (LVAD) therapy improves the haemodynamics of advanced heart failure patients. However, it is unknown whether haemodynamic optimization improves haemocompatibility‐related adverse events (HRAEs). This study aimed to assess HRAEs in patients with optimized haemodynamics. Methods and results Eighty‐three outpatients [aged 61 (53–67) years, 50 male] underwent a haemodynamic ramp test at 253 (95–652) days after LVAD implantation, and 51 (61%) had optimized haemodynamics (defined as central venous pressure < 12 mmHg, pulmonary artery wedge pressure < 18 mmHg, cardiac index > 2.2 L/min/m2) following LVAD speed adjustment. One‐year survival free of any HRAEs (non‐surgical bleeding, thromboembolic event, pump thrombosis, or neurological event) was achieved in 75% of the optimized group and in 44% of the non‐optimized group (hazard ratio 0.36, 95% confidence interval 0.18–0.73, P = 0.003). The net haemocompatibility score, using four escalating tiers of hierarchal severity to derive a total score for events, was significantly lower in the optimized group than the non‐optimized group (1.02 vs. 2.00 points/patient; incidence rate ratio 0.51, 95% confidence interval 0.29–0.90, P = 0.021). Conclusion Left ventricular assist device patients in whom haemodynamics can be optimized had greater freedom from HRAEs compared to those without optimized haemodynamics.
Background Cannula and pump positions are associated with clinical outcomes such as device thrombosis in patients with HeartMate II; however, clinical implications of HVAD (HeartWare International, Framingham, Massachusetts) cannula position are unknown. This study aims to assess the relationship among cannula position, left ventricular (LV) unloading, and patient prognosis. Methods and results Twenty-seven HVAD patients (60.0 ± 12.6 years of age and 19 males [70%]) underwent ramp test. Device position was quantified from chest X-ray parameters obtained at the time of the hemodyamic ramp test: (1) cannula coronal angle, (2) pump depth, (3) cannula sagittal angle, and (4) pump area. Lower cannula coronal angle was associated with LV unloading (as measured by smaller LV diastolic dimension and lower pulmonary capillary wedge pressure). Smaller pump area was associated with LV dynamic unloading, as assessed by steeper negative slopes of LV diastolic dimension and pulmonary capillary wedge pressure during incremental rotational speed change. Cannula coronal angle ≤65° was associated with reduced heart failure readmission rate (hazard ratio, 10.33; P = .007 by log-rank test). Conclusion HVAD cannula and pump positions are associated with LV unloading and improved clinical outcomes. Prospective studies evaluating surgical techniques to ensure optimal device positioning and its effects on clinical outcomes are warranted.
BACKGROUND: Gastrointestinal bleeding (GIB) is a common complication seen in patients supported with left ventricular assist devices (LVADs) and is related to increased inflammation and angiogenesis. Omega-3 is an unsaturated fatty acid that possesses anti-inflammatory and antiangiogenic properties. This study aims to assess the prophylactic efficacy of treatment with omega-3 on the incidence of GIB in LVAD patients. METHODS AND RESULTS: Among consecutive 166 LVAD patients enrolled in this analysis, 30 patients (49 years old and 26 male) received 4 mg/d of omega-3 therapy for 310±87 days and 136 patients in the control group (58 years old and 98 male) were observed for 302±102 days. One-year GIB-free rate was significantly higher in the omega-3 group as compared with the control group (97% versus 73%; P=0.02). Omega-3 therapy was associated with the occurrence of GIB in both the univariate (hazard ratio, 0.12; 95% CI, 0.02–0.91; P=0.040) and multivariate Cox proportional hazard ratio analyses (hazard ratio, 0.13; 95% CI, 0.02–0.98; P=0.047). The frequency of GIB was significantly lower in the omega-3 group (0.08±0.42 versus 0.37±0.93 events/y; P=0.01), accompanied by significantly lower blood product transfusion and shorter days in the hospital. The frequency of GIB remained lower among the omega-3 group after matching for patient background characteristics (96% versus 73%, P=0.028). CONCLUSIONS: LVAD patients treated with omega-3 had a significant increase in freedom from GIB. A randomized controlled study is warranted to evaluate the use of omega-3 in LVAD patients.
The relationship between the HeartMate II left ventricular assist device (LVAD) position and pump thrombosis has been reported. However, further clinical implications of device position are unknown. This study aimed to investigate optimal device position for better left ventricular (LV) unloading and patient prognosis. Patients undergoing a ramp test with right heart catheterization after HeartMate II LVAD implantation were enrolled to this study. Device position was quantified from the chest X-ray obtained at the time of the ramp test: (1) inflow cannula angle relative to horizontal line, (2) pump angle relative to spine, (3) pump depth, (4) angle between inflow cannula and pump, and (5) angle between pump and outflow graft. LV unloading was assessed by pulmonary capillary wedge pressure at set LVAD speed. Fifty-four patients (60 years old and 34 male [63%]) were enrolled. Nobody experienced device malfunction during the study period. Increased LV unloading (i.e., lower pulmonary capillary wedge pressure) was associated with a narrower inflow cannula angle relative to horizontal line. Inflow cannula angle <75° was associated with higher 1 year heart failure readmission-free survival rate (p < 0.05, hazards ratio 7.56 [95% confidence interval 2.32-24.7]). In conclusion, HeartMate II LVAD inflow cannula position was associated with LV unloading and patient prognosis. Prospective studies to ensure optimal device positioning and target better clinical outcomes are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.